Relay Panel Wire H07V-K For Compact Control Connections

Relay Panel Wire H07V-K For Compact Control Connections
Details:
·Conductor: Class 5 flexible copper conductor
·Insulation: PVC (Polyvinyl Chloride)
·Voltage Rating Uo/U: H05V-K:300/500V ; H07V-K:450/750V
·Temperature Rating: Fixed: -30°C to +70℃ ; Flexed: -5°C to +70℃
·Standards: EN 50525-2-31, EN 60228 ; Flame Retardant according to IEC/EN 60332-1-2 ; UV Resistant
Send Inquiry
Download
Description
Technical Parameters
Certification

PVC wire for control panels

PRODUCT REAL SHOT

 

electrical control panels wire
electrical control panels wiring cable
flexible wire for electrical control panels

single core cable for electrical control panels

Flexible Relay Wiring Cable for Protected Panel Circuits
Relay panels can involve dozens of short conductors between terminal blocks, coils, contacts, indicators and protection devices. H07V-K helps simplify relay cabinet wiring because its flexible stranded copper conductor is easier to dress around tight panel layouts than rigid conductors. As a control circuit conductor, it supports neat point-to-point routing and practical ferrule termination in repetitive panel work. GERITEL WIRE can supply colour-coordinated production lots, OEM identification and packaging suited to panel assembly lines. Buyers choosing fine stranded panel wire should confirm circuit function and local requirements, especially where shielding, fire-performance upgrades or special environmental resistance may require another cable type.
PRODUCT SPECIFICATIONS

 

PVC wire for electrical control panels

Applications

 

PVC panel wiring for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers.

SPECIFICATIONS
Voltage Rating Uo/U

H05V-K:300/500V

H07V-K:450/750V

Temperature Rating

Fixed: -30°C to +70°C

Flexed: -5°C to +70°C

Minimum Bending Radius Fixed: 6 x overall diameter
Conductor Class 5 flexible copper conductor
Insulation PVC (Polyvinyl Chloride)
Insulation Colour Red,Black,Blue,Orange,Yellow,White,Green/Yellow,Violet,Pink,Grey,Brown
STANDARDS

EN 50525-2-31,EN 60228

Flame Retardant according to IEC/EN 60332-1-2

UV Resistant

DIMENSIONS

NOMINAL CROSS SECTIONAL AREA

mm²

NOMINAL OVERALL DIAMETER

mm²

NOMINAL WEIGHT

kg/km

H05V-K
0.5 2.20 9.1
0.75 2.40 11.7
1 2.55 14.4
H07V-K
1.5 3.00 20.1
2.5 3.65 31.5
4 4.20 46.2
6 4.80 65.1
10 6.25 109.4
16 7.40 165.2
25 9.40 253.4
35 10.40 345.5
50 12.55 492.4
70 14.10 669.3
95 17.20 910.4
120 17.70 1129.4
150 19.60 1401.0
185 23.00 1741.0
240 26.40 2267.5

CONDUCTORS

NOMINAL CROSS

SECTIONAL AREA

mm²

MAXIMUM DIAMETER

OF WIRES IN CONDUCTOR

mm

MAXIMUM RESISTANCE OF CONDUCTOR AT 20°C

ohms/km

Plain Wires
0.5 0.21 39
0.75 0.21 26
1 0.21 19.5
1.5 0.26 13.3
2.5 0.26 7.98
4 0.31 4.95
6 0.31 3.3
10 0.41 1.91
16 0.41 1.21
25 0.41 0.78
35 0.41 0.554
50 0.41 0.386
70 0.51 0.272
95 0.51 0.206
120 0.51 0.161
150 0.51 0.129
185 0.51 0.106
240 0.51 0.0801

ELECTRICAL CHARACTERISTICS

NOMINAL CROSSS

ECTIONAL AREA

mm²

REFERENCE METHOD A

(ENCLOSED IN

CONDUIT IN THERMALLY

INSULATING WALL ETC)

Amps

REFERENCE METHOD B

(ENCLOSED IN CONDUIT

IN WALL OR IN

TRUNKING ETC)
Amps

REFERENCE METHOD C

(CLIPPED DIRECT)
Amps

REFERENCE METHOD F

(IN FREE AIR OR ONA PERFORATED CABLE TRAY ETC HORIZONTAL OR VERTICAL ETC)

Amps

Touching

Spaced by

one diameter

2 Cables Single-Phase ACor DC or3 Cables Three-Phase AC flat

2 Cables

Single-Phase

ACor DC

3 or 4 Cables

Three-Phase

AC

2 Cables

Single-Phase

ACor DC

3 or 4 Cables

Three-Phase

AC

2 Cables

Single-Phase

AC or DC

3 or 4Cables

Three-Phase

AC

2Cables

SinglePhase

AC or DCflat

3Cables

Three-Phase

ACflat

3 Cables

Three-Phase

ACtrefoil

Horizontal Vertical
1.5 14.5 13.5 17.5 15.5 20 18 - - - - -
2.5 20 18 24 21 27 25 - - - - -
4 26 24 32 28 37 33 - - - - -
6 34 31 41 36 47 43 - - - - -
10 46 42 57 50 65 59 - - - - -
16 61 56 76 68 87 79 - - - - -
25 80 73 101 89 114 104 131 114 110 146 130
35 99 89 125 110 141 129 162 143 137 181 162
50 119 108 151 134 182 167 196 174 167 219 192
70 151 136 192 171 234 214 251 225 216 281 254
95 182 164 232 207 284 261 304 275 264 341 311
120 210 188 269 239 330 303 352 321 308 396 362
150 240 216 300 262 381 349 406 372 356 456 419
185 273 245 341 296 436 400 463 427 409 521 480
240 321 286 400 346 515 472 546 507 485 615 569
CERTIFICATIONS

 

industrial control panels wire

industrial control panels wiring cable

PACKAGING

 

flexible wire for industrial control panels

Roll

single core cable for industrial control panels

Plastic Reel

PVC wire for industrial control panels

Small Wooden Reel

APPLICATION

 

control cabinets wire
Industrial Control Panel
control cabinets wiring cable
Renewable Energy Power Connection
flexible wire for control cabinets

Switchboard Wiring

 

CASE

 

single core cable for control cabinets

Adelaide Airport Switchboard Upgrade

PVC wire for control cabinets

Industrial Main Switchboard Power Distribution

electrical control cabinets wire

Main Switchboard Flexible Cable Replacement

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

electrical control cabinets wiring cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

flexible wire for electrical control cabinets
 
Class 5 flexible wire manufacturersingle core cable for electrical control cabinets
 
PVC wire for electrical control cabinets
 
automation control cabinets wire
 
automation control cabinets wiring cable
 
flexible wire for automation control cabinets
 
GLOBAL CERTIFICATIONS

 

single core cable for automation control cabinets

CUSTOMER PHOTOS
 

PVC wire for automation control cabinets

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

PLC control cabinets wire
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

PLC control cabinets wiring cable
flexible wire for PLC control cabinets
single core cable for PLC control cabinets
PVC wire for PLC control cabinets
relay panels wire
relay panels wiring cable
flexible wire for relay panels
single core cable for relay panels
PVC wire for relay panels
instrumentation panels wire
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

instrumentation panels wiring cable
FAQ

 

Can H07V-K be installed in trunking?
It is commonly used as trunking panel wire in protected panel and electrical-installation routes where the local code permits flexible single-core conductors. Keep the cable protected from sharp edges and excessive fill or heat buildup. GERITEL WIRE can align production packing with panel-shop handling, automated wire processing or distributor stocking requirements for repeat orders.
Can H07V-K be laid directly on open cable tray?
Do not assume open cable tray H07V-K installation is permitted. Manufacturer instructions and local rules differ, and some H07V-K products are intended for conduit or enclosed systems rather than direct tray laying except for specific bonding uses. If the project has several circuits or destination markets, GERITEL WIRE can help separate H07V-K applications from circuits that need LSZH, screened, high-temperature or continuous-flex cable.
Can H07V-K be buried directly underground?
Standard H07V-K is not a direct burial cable alternative. It lacks the sheath and environmental protection normally required for soil, moisture and mechanical exposure, so use a cable specifically approved for direct burial. GERITEL WIRE can provide technical data review and practical export packing so the purchasing team has clearer information before approving mass production..
Can H07V-K be used outdoors?
Outdoor H07V-K wiring should not be assumed suitable unless the exact product has the required UV, weather and installation protection. Standard H07V-K is primarily a protected/fixed wiring product, so outdoor runs often need conduit or another cable family. For long-term programs, GERITEL WIRE can coordinate consistent colour identification, labels and order documentation to reduce avoidable receiving and assembly errors.

 

Hot Tags: relay panel wire h07v-k for compact control connections, China relay panel wire h07v-k for compact control connections manufacturers, suppliers, factory, HO7V-K

Send Inquiry