Armor: Interlocked Galvanized Steel Strip (Painted Red) ;
-
Conductors: Solid Copper ;
-
Conductor Insulation: TFN 18 & 16 AWG and/or THHN 14 & 12 AWG ;
-
Assembly: Polyester Assembly Tape;
-
Maximum Temperature Rating: FPLP: 105°C (Dry), MC: 90°C (Dry)
-
Grounding: One or More Grounding Conductors May Be Bare or Insulated Green
-
Maximum Voltage Rating: 300V (FPLP); 600V (MC
Feature

Certification
Fire alarm MC cable has passed UL certification, which can significantly enhance the market credibility of the product. When choosing electrical products, customers tend to prefer those that meet UL certification, which can ensure the reliability of the product under extreme conditions, especially in fire alarm systems, where any minor electrical problems may lead to serious consequences.

Package

Factory

GREATER company is a ul cable factory, dedicated to providing high-quality cable products to global customers, especially in fire alarm mc cable and MC cables used in fire alarm systems.
As one of the industry's leading MC cable supplier, GREATER has established a wide influence in the global market with its years of experience and technological innovation. Its MC cables are widely used in power transmission and security systems in commercial buildings, industrial facilities, and residential areas, especially in the key role of fire alarm systems
As a professional mc armored cable supplier, GREATER is committed to providing high-quality cable solutions to global customers. Whether it is a commercial project, industrial facility or residential building, GREATER can provide cable products tailored to the needs of customers. GREATER's MC cables have a wide range of applications, from power systems, communication systems to fire alarm systems, all of which can provide reliable power and signal transmission.
Case

Partner

FAQ
Q: What is the standard cable for a fire alarm MC cable ?
2. UL 1569 applies to MC cables (Metal Clad Cables), which are metal sheathed cables. This standard specifies the requirements that MC cables must meet during the design and manufacturing process to ensure that the cables meet relevant requirements in terms of fire resistance and resistance to mechanical damage.
Therefore, if MC cables are used in fire alarm systems, other properties of the cable (such as fire resistance) are usually required to be confirmed, so it is necessary to ensure that it meets the requirements of UL 1424, or choose a version with additional fire protection properties according to actual needs
Q: Can MC cables be used for a fire alarm?
Hot Tags: ul 18/2 fire alarm mc cable, China ul 18/2 fire alarm mc cable manufacturers, suppliers, factory, HO7V-U, 300 300V 2 3 4 Core H03VV F Cable, XLPE Copper Cable, mc cable, cul standard rw75 rw90 rwu75 rwu90 cable, xhhw rw 90 rhw wire

| CONDUCTOR | Insulation Thickness (mils) | Ground Wire | Nominal Total Weight (lbs/1000') | |||
| No. of Conductors | Size (AWG or kcmil) | No. of Strands | Size (AWG) | Nom. OD (mils) | ||
| 6 | 18AWG | 1 | 15 | 14 | 771 | 252 |
| 2 | 18AWG | 1 | 15 | 18 | 371 | 56 |
| 2 | 18AWG | 1 | 15 | 18 | 376 | 58 |
| 4 | 18AWG | 1 | 15 | 18 | 419 | 77 |
| 6 | 18AWG | 1 | 15 | 18 | 443 | 94 |
| 2 | 16AWG | 1 | 15 | 16 | 417 | 72 |
| 4 | 16AWG | 1 | 15 | 16 | 448 | 97 |
| 6 | 16AWG | 1 | 15 | 16 | 490 | 122 |
| 4 | 14AWG | 0 | 15 | 12 | 617 | 137 |
| 4 | 14AWG | 1 | 15 | 16 | 658 | 155 |
| 4 | 14AWG | 1 | 15 | 14 | 613 | 136 |
| 4 | 14AWG/14AWG | 1 | 15 | 14 | 691 | 176 |
| 2 | 14AWG | 1 | 15 | 14 | 432 | 90 |
| 3 | 14AWG | 19 | 15 | 14 | 478 | 115 |
| 4 | 14AWG | 1 | 15 | 14 | 489 | 129 |
| 4 | 12AWG | 1 | 15 | 12 | 684 | 180 |
| 2 | 12AWG | 1 | 15 | 12 | 483 | 119 |
| 4 | 12AWG | 1 | 15 | 12 | 530 | 174 |
| 6 | 10AWG | 19 | 20 | 10 | 775 | 502 |
| 16 | 10AWG | 19 | 20 | 10 | 1023 | 769 |