Details:
Good electrical conductivity and resistance to corrosion
Multiple strands twisted together for flexibility
More than 20 years of production experience
Quick online quote & free samples available
Send Inquiry
Download
Description
Technical Parameters
Certification
AAC cable

 

AAC Bare Aluminium Wire
  • Aluminum 1350-H19 wires, concentrically stranded
  • B230 Aluminum 1350-H19 Wire for Electrical Purposes
  • B231 Concentric-Lay-Stranded Aluminum 1350 Conductors

 

Application

 

 

AAC bare aluminium wire is mainly used for overhead transmission and distribution services. AAC conductors are usually made of 1350 aluminium stranded together. Due to its excellent conductivity and light weight, it is an ideal choice for power transmission. AAC conductors have a wide range of applications in overhead lines, especially for low to medium strength transmission requirements. Class AA bare conductors are commonly used in overhead power lines. They can provide stable power transmission under normal environmental conditions without excessive mechanical strength. For some applications that require additional protection or greater flexibility, AAC also provides a Class A version. The conductor can be covered with weather-resistant material or used as a bare conductor in places where greater flexibility is required.

bare AAC cable application

 

Feature

 

AAC wire

 

AAC bare aluminum wire is composed of aluminum alloy 1350-H19 wire, with a concentric layer twisted structure, which has excellent conductivity and corrosion resistance. According to different application requirements, AAC conductors can provide single-layer and multi-layer structures. The single-layer structure is suitable for power transmission over shorter distances, while the multi-layer structure provides higher mechanical strength and greater conductivity, which is suitable for long-distance, high-load power transmission.

 

 

Certification

 

 

AAC (All Aluminum Conductor) is UL certified. This product complies with relevant international and domestic quality standards and safety regulations. It usually undergoes strict inspection and testing procedures, such as conductivity, tensile strength, corrosion resistance and high temperature resistance, etc., to ensure the stability and safety of the cable in various environments.

AAC wire

 

Package

 

AAC wire  package

 

Factory

 

AAC cable manufacturer

 

Greater Wire manufacturer's advanced cable factory has an intelligent and digital manufacturing environment. Through the seamless integration of cutting-edge technology, the factory successfully eliminates errors and defects that may occur in the traditional manual assembly process. The shift to digital manufacturing not only increases efficiency but also demonstrates our commitment to providing our customers with products of the highest reliability. The smart factory framework ensures a streamlined and error-free production process, minimizing the possibility of human-related variances and increasing previously unattainable precision. Accurate and automated inspection mechanism, the factory strictly adheres to quality control. Products are thoroughly inspected from the beginning to the final stage of the manufacturing process. Digital intelligent image detection and laser technologies are used to ensure that each product meets the strict standards set by our company. This commitment to quality extends to our inspection accuracy, with automated production equipment achieving an impressive accuracy of 0.002 mm, exceeding industry benchmarks.

 

Case

 

wire and cable Company cases

 

Partner

 

greater wire Partner

 

FAQ

 

Q: Are you a manufacturer or trading company?

A: We are a professional manufacturer, offering full control over your order from start to finish. From initial design to final delivery, we ensure every step meets the highest standards.

Q:  How is the quality of these products?

A: Our products have passed many certifications, such as UL, SAA, TUV, CE, CB, and others. Over 20 years of experience in this area, Providing wires and cables to more than 90 countries around the world.

 

 

Hot Tags: aac bare aluminium wire, China aac bare aluminium wire manufacturers, suppliers, factory, SAA Approval SDI Cable, xlpe armoured cable, xhhw rw 90 rhw wire, mc cable, silicone wire, 0 6 1KV Single Core Building Cable

AAC cable

 

 

Code Word Size (AWG or kcmil) Stranding Diameter (ins.) Cross Sectional Area (Sq. ins.) Weight Per 1000 ft. (lbs.) Rated Strength (lbs.) Resistance OHMS/1000 ft. Allowable Ampacity (Amps)
No. of Wires Class Individual Wires Complete Cable DC @ 20°C AC @ 75°C
Peachbell 6 7 A .0612 .184 .0206 25 563 .658 .805 103
Rose 4 7 A .0772 .232 .0328 39 881 .414 .506 138
lris 2 7 AA, A .0974 .292 .0522 62 1350 .260 .318 185
Pansy 1 7 AA .1093 .328 .0657 78 1640 .207 .252 214
Poppy 1/0 7 AA, A .1228 .368 .0829 99 1990 .164 .200 247
Aster 2/0 7 AA, A .1379 .414 .1045 125 2510 .130 .159 286
Phlox 3/0 7 AA, A .1548 .464 .1317 157 3040 .103 .126 331
Oxlip 4/0 7 AA, A .1739 .522 .1663 198 3830 .0817 .0999 383
Sneezewort 250 7 AA .189 .567 .1964 234 4520 .0691 .0846 425
Valerian 250 19 A .1147 .574 .1963 234 4660 .0691 .0846 426
Daisy 266.8 7 AA .1952 .586 .2095 250 4830 .0648 .0793 443
Laurel 266.8 19 A .1185 .592 .2095 250 4970 .0648 .0793 444
Peony 300 19 A .1257 .628 .2358 281 5480 .0576 .0706 478
Tulip 336.4 19 A .1331 .665 .2644 315 6150 .0514 .0630 513
Daffodil 350 19 A .1357 .679 .2748 328 6390 .0494 .0605 528
Canna 397.5 19 AA, A .1446 .723 .312 373 7110 .0435 .0534 570
Goldentuft 450 19 AA .1539 .769 .3534 422 7890 .0384 .0472 616
Cosmos 477 19 AA .1584 .792 .3744 447 8360 .0362 .0445 639
Syringa 477.0 37 A .1135 .795 .3744 447 8690 .0362 .0445 639
Zinnia 500 19 AA .1622 .811 .3926 469 8760 .0346 .0425 658
Hyacinth 500 37 AA .1162 .814 .3924 469 9110 .0346 .0425 658
Dahlia 556.5 19 AA .1711 .856 .4369 522 9750 .0311 .0382 703
Mistletoe 556.5 37 AA .1226 .858 .4368 522 9940 .0311 .0382 704
Meadowsweet 600 37 AA .1273 .891 .4709 562 10700 .0228 .0355 738
Orchid 636.0 37 AA, A .1311 .918 .4995 596 11400 .0272 .0335 765
Heuchera 650 37 AA .1325 .928 .5102 609 11600 .0266 .0328 775
Verbena 700 37 AA .1375 .963 .5494 656 12500 .0247 .0305 812
Flag 700 61 A .1071 .964 .5495 656 12900 .0247 .0305 812
Violet 715.5 37 AA .1391 .973 .5623 671 12800 .0242 .0299 823
Nasturtium 715.5 61 AA .1083 .975 .5619 671 13100 .0242 .0299 823
Petunia 750.0 37 AA .1424 .997 .5893 703 13100 .0230 .0286 847
Cattail 750 61 AA .1109 .998 .5892 703 13500 .0230 .0286 847
Arbutus 795 37 AA .1466 1.026 .6245 745 13900 .0217 .0270 878
Lilac 795.0 61 A .1142 1.027 .6248 745 14300 .0217 .0270 879
Cockscomb 900 37 AA .156 1.092 .7072 844 15400 .0192 .0239 948
Snapdragon 900 61 AA .1215 1.093 .7072 844 15900 .0192 .0239 948
Magnolia 954.0 37 AA .1606 1.124 .7495 894 16400 .0181 .0226 982
Goldenrod 954.0 61 A .1251 1.125 .7498 894 16900 .0181 .0226 983
Hawkweed 1000 37 AA .1644 1.151 .7854 937 17200 .0173 .0216 1010
Camellia 1000 61 AA .128 1.152 .7849 937 17700 .0713 .0216 1011
Bluebell 1033.5 37 AA .1671 1.17 .8114 969 17700 .0167 .0210 1031
Larkspur 1033.5 61 AA .1302 1.171 .8122 969 18300 .0167 .0210 1032
Marigold 1113.0 61 AA, A .1351 1.216 .8744 1043 19700 .0155 .0195 1079
Hawthorm 1192.5 61 AA, A .1398 1.258 .9363 1118 21100 .0145 .0183 1124
Narcissus 1272.0 61 AA, A .1444 1.3 .999 1192 22000 .0136 .0173 1169
Columbine 1351.5 61 AA, A .1488 1.34 1.0608 1267 23400 .0128 .0163 1212
Carnation 1431 61 AA, A .1532 1.378 1.1244 1341 24300 .0121 .0155 1253
Gladiolus 1510.5 61 A .1574 1.416 1.1869 1416 25600 .0144 .0147 1294
Coreopsis 1590.0 61 AA .1614 1.453 1.248 1490 27000 .0109 .0141 1333
Jessamine 1750.0 61 AA .1694 1.524 1.3748 1640 29700 .00988 .0129 1408
Cowslip 2000.0 91 A .1482 1.631 1.5697 1875 34200 .00864 .0115 1518
Sagebrush 2250 91 A .1572 1.73 1.7662 2130 37500 .00776 .0105 1612
Lupine 2500.0 91 A .1657 1.823 1.9623 2366 41900 .00698 .00969 1706
Bitterroot 2750 91 A .1738 1.912 2.1589 2603 46100 .00635 .00900 1793
Trillium 3000 127 A .1537 1.998 2.3564 2839 50300 .00582 .00834 1874
Bluebonnet 3500 127 A .166 2.158 2.7486 3345 58700 .00499 .00756 2024

 

Conductor temperature of 75ºC, ambient temperature 25ºC, emissivity 0.5, wind 2 ft./sec. in sun.

Send Inquiry