120mm2 Single Core Electrical Cable Plain Annealed Copper

120mm2 Single Core Electrical Cable Plain Annealed Copper
Details:
·Insulation:V-90 PVC
·Plain annealed copper conductor to AS/NZS 1125
·Maximum continuous operating temperature:75℃
·PVC INSULATED ONLY CABLE TO AS/NZS 5000.1
·Colours: Red,Black,White,Blue,Green/Yellow
Send Inquiry
Download
Description
Technical Parameters
Certification

120mm2 V90 single core cable

PRODUCT REAL SHOT

 

120 mm² V-90 building wire
120mm² PVC insulated single core cable
120 sq mm copper building wire

120mm2 conduit wire

Single Insulated Copper Cable for Project Distribution Systems
120mm2 V-90 building wire uses thirty-seven 2.03 mm plain annealed copper wires, forming a Class 2 conductor for fixed connections in distribution boards, switchgear assemblies, industrial control rooms and protected apparatus. The 37 strand copper conductor cable is manufactured to AS/NZS 1125 and insulated with V-90 PVC under AS/NZS 5000.1. As a 0.6/1kV PVC power wire, it is supplied without an outer sheath and is specified for 75°C maximum continuous operation, so installation protection must be provided by the selected wiring system. GERITEL WIRE can coordinate colour, printing, cut lengths, drums and delivery identification. Engineering checks should cover current, fault duty, voltage drop, grouping, support and terminal size.
PRODUCT SPECIFICATIONS

 

120mm2 copper conduit wire

Applications

 

For seperate earth conductors. For switchboard and control panel wiring. For fixed wiring within other enclosures or apparatus where the cable is not accessible without the use of tools. For use where improved aging properties to those of 75°C PVC are required because of higher ambient temperatures. Suitable for glanding

SPECIFICATIONS
CONDUCTOR

Plain annealed copper conductor to AS/NZS 1125
Maximum continuous operating temperature: 75°C

Can also be operated at temperatures up to 90°C when not exposed to mechanical deformation (see AS/NZS 3008.1)

INSULATION V-90 PVC
Colours: Red, Black, White, Blue, Green/Yellow

Conductor

Cable

Min.

installed

bending

radius

mm

Nominal

C.S.A

mm²

Nominal

diameter

of wires
No/mm

Nominal

diameter

mm

Nominal

insulation

thickness

mm

Overall diameter

Approx.

mass

kg/100 m

Minimum

mm

Maximum

mm

1.0* 1/11.3 1.13 0.8 2.6 2.8 1.7 10
1.5 7/0.50 1.5 0.8 3.0 3.2 2.2 15
2.5* 1/1.78 1.78 0.8 3.3 3.5 3.3 15
2.5 7/0.67 2.0 0.8 3.5 3.7 3.4 15
4 7/0.85 2.6 1.0 4.5 4.6 5.4 20
6 7/1.04 3.1 1.0 5.1 5.2 7.6 20
10 7/1.35 4.1 1.0 6.0 6.1 12 25
16 7/1.70 5.1 1.0 7.1 7.2 18 30
25 19/1.35 6.8 1.2 9.1 9.3 27 35
35 19/1.53 7.7 1.2 10.0 10.1 36 40
50 19/1.78 8.9 1.4 11.6 11.9 51 50
70 19/2.14 10.7 1.4 13.4 13.5 70 55
95 19/1.45 12.5 1.6 15.9 15.9 98 65
120 37/2.03 14.2 1.6 17.4 17.4 120 70
150 37/2.25 15.8 1.8 19.5 19.5 148 80
185 37/2.52 17.6 2.0 21.7 21.7 185 90

Conductor

nominal

C.S.A.

mm²

Current rating (a) Electrical characteristics
Three phase Single phase

Maximum D.C.

resistance

at20°C

Ω/km

Reactance per core

(Trefoil, Touching)

Ω/km

In conduit

in air A

Underground

in duct A

In conduitinair A

Underground

in duct A

1.0* 11 16 13 18 18.1 0.119
1.5 14 20 16 24 13.6 0.111
2.5* 20 28 22 33 7.41 0.102
2.5 20 28 22 33 7.41 0.102
4 26 37 30 42 4.61 0.102
6 34 46 38 53 3.08 0.0967
10 47 61 53 71 1.83 0.0906
16 62 80 71 91 1.15 0.0861
25 87 105 97 120 0.727 0.0853
35 100 125 115 145 0.524

0.0826

50 125 150 140 170 0.387 0.0797
70 155 185 175 210 0.268 0.0770
95 185 225 210 260 0.193 0.0766
120 220 260 250 295 0.153 0.0743
150 250 290 280 335 0.124 0.0745
185 285 335 325 380 0.0991 0.0744
CERTIFICATIONS

 

120mm2 0.6/1kV building wire

120mm2 600/1000V single core wire

PACKAGING

 

120mm2 AS/NZS 5000.1 cable

Roll

120mm2 AS/NZS 1125 copper wire

Plastic Reel

1C x 120mm2 V90 PVC cable

Small Wooden Reel

APPLICATION

 

1 x 120 mm² building wire
Industrial Control Panel
120mm2 unsheathed copper cable
Renewable Energy Power Connection
120mm2 fixed wiring cable

Switchboard Wiring

 

CASE

 

120mm2 switchboard wiring cable

Adelaide Airport Switchboard Upgrade

120mm2 control panel wiring cable

Industrial Main Switchboard Power Distribution

120mm2 building wire supplier

Main Switchboard Flexible Cable Replacement

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

120mm2 building wire manufacturer
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

120mm2 V90 copper wire price
 
120mm2 V90 cable datasheet
 
50mm2 stranded copper conductor 19/1.78 V90 cable
 
70mm2 stranded copper conductor 19/2.14 V90 cable
 
95mm2 stranded copper conductor 19/2.45 V90 cable
 
120mm2 stranded copper conductor 37/2.03 V90 cable
 
GLOBAL CERTIFICATIONS

 

150mm2 stranded copper conductor 37/2.25 V90 cable

CUSTOMER PHOTOS
 

185mm2 stranded copper conductor 37/2.52 V90 cable

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

V90 building wire wholesale
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

bulk V90 single core cable
AS/NZS 5000.1 cable supplier Australia
AS/NZS 5000.1 cable supplier New Zealand
V90 building wire exporter
copper conduit wire factory
OEM V90 building wire
custom colour V90 cable
red black white blue building wire supplier
green yellow earth wire manufacturer
0.6/1kV building wire quotation
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

600/1000V conduit wire price
FAQ

 

Should stranded wire ends be solder-tinned before termination?
Stranded copper wire termination should follow the device and wiring-system instructions; solder-tinning is not a universal solution and may create long-term clamping issues in some terminals. GERITEL WIRE recommends approved ferrules or lugs where required and can provide strand details for tooling selection.
Can solid and stranded conductors share the same terminal?
A solid and stranded wire connection should only share a terminal when the terminal is specifically approved for both conductors and the exact arrangement. Different compression behaviour can cause a poor joint. GERITEL WIRE helps buyers identify the conductor class so the panel builder can select compliant terminals or separate connectors.
Can V90 single core conductors be installed in parallel?
Parallel single core conductors require compliance with rules covering minimum size, equal length, conductor material, termination and current sharing. GERITEL WIRE can manufacture matched size and length sets, but the parallel arrangement must be designed and approved by a qualified engineer before the order is released.
Can AC single core cables pass through separate steel gland holes?
A single core AC cable gland arrangement must avoid harmful magnetic heating in ferrous metal. Phase and neutral conductors may need to pass through a common opening or use a suitable non-ferrous gland plate. GERITEL WIRE can provide cable dimensions, while the switchboard designer confirms the gland layout.

 

Hot Tags: 120mm2 single core electrical cable plain annealed copper, China 120mm2 single core electrical cable plain annealed copper manufacturers, suppliers, factory

Send Inquiry