95mm2 1C Copper Building Cable 600/1000V V-90

95mm2 1C Copper Building Cable 600/1000V V-90
Details:
·Insulation:V-90 PVC
·Plain annealed copper conductor to AS/NZS 1125
·Maximum continuous operating temperature:75℃
·PVC INSULATED ONLY CABLE TO AS/NZS 5000.1
·Colours: Red,Black,White,Blue,Green/Yellow
Send Inquiry
Download
Description
Technical Parameters
Certification

95mm2 V90 single core cable

PRODUCT REAL SHOT

 

95 mm² V-90 building wire
95mm² PVC insulated single core cable
95 sq mm copper building wire

95mm2 conduit wire

Low Voltage Copper Wire for Main Panel Connections
95mm2 V90 single core wire is built with a 19/2.45 mm plain annealed copper conductor for protected connections in main switchboards, distribution assemblies, plant panels and equipment enclosures. The PVC insulated switchboard conductor is rated 600/1000V and has no outer sheath, so it should be installed within a fixed-wiring method that provides appropriate protection and support. Manufactured as an AS/NZS 5000.1 fixed wiring cable with conductor construction to AS/NZS 1125, it has a 75°C maximum continuous operating temperature. GERITEL WIRE can support colour identification, printing, cut lengths and drum packing. Selection should confirm current, fault withstand, derating, voltage drop, bend space and terminal arrangement.
PRODUCT SPECIFICATIONS

 

95mm2 copper conduit wire

Applications

 

For seperate earth conductors. For switchboard and control panel wiring. For fixed wiring within other enclosures or apparatus where the cable is not accessible without the use of tools. For use where improved aging properties to those of 75°C PVC are required because of higher ambient temperatures. Suitable for glanding

SPECIFICATIONS
CONDUCTOR

Plain annealed copper conductor to AS/NZS 1125
Maximum continuous operating temperature: 75°C

Can also be operated at temperatures up to 90°C when not exposed to mechanical deformation (see AS/NZS 3008.1)

INSULATION V-90 PVC
Colours: Red, Black, White, Blue, Green/Yellow

Conductor

Cable

Min.

installed

bending

radius

mm

Nominal

C.S.A

mm²

Nominal

diameter

of wires
No/mm

Nominal

diameter

mm

Nominal

insulation

thickness

mm

Overall diameter

Approx.

mass

kg/100 m

Minimum

mm

Maximum

mm

1.0* 1/11.3 1.13 0.8 2.6 2.8 1.7 10
1.5 7/0.50 1.5 0.8 3.0 3.2 2.2 15
2.5* 1/1.78 1.78 0.8 3.3 3.5 3.3 15
2.5 7/0.67 2.0 0.8 3.5 3.7 3.4 15
4 7/0.85 2.6 1.0 4.5 4.6 5.4 20
6 7/1.04 3.1 1.0 5.1 5.2 7.6 20
10 7/1.35 4.1 1.0 6.0 6.1 12 25
16 7/1.70 5.1 1.0 7.1 7.2 18 30
25 19/1.35 6.8 1.2 9.1 9.3 27 35
35 19/1.53 7.7 1.2 10.0 10.1 36 40
50 19/1.78 8.9 1.4 11.6 11.9 51 50
70 19/2.14 10.7 1.4 13.4 13.5 70 55
95 19/1.45 12.5 1.6 15.9 15.9 98 65
120 37/2.03 14.2 1.6 17.4 17.4 120 70
150 37/2.25 15.8 1.8 19.5 19.5 148 80
185 37/2.52 17.6 2.0 21.7 21.7 185 90

Conductor

nominal

C.S.A.

mm²

Current rating (a) Electrical characteristics
Three phase Single phase

Maximum D.C.

resistance

at20°C

Ω/km

Reactance per core

(Trefoil, Touching)

Ω/km

In conduit

in air A

Underground

in duct A

In conduitinair A

Underground

in duct A

1.0* 11 16 13 18 18.1 0.119
1.5 14 20 16 24 13.6 0.111
2.5* 20 28 22 33 7.41 0.102
2.5 20 28 22 33 7.41 0.102
4 26 37 30 42 4.61 0.102
6 34 46 38 53 3.08 0.0967
10 47 61 53 71 1.83 0.0906
16 62 80 71 91 1.15 0.0861
25 87 105 97 120 0.727 0.0853
35 100 125 115 145 0.524

0.0826

50 125 150 140 170 0.387 0.0797
70 155 185 175 210 0.268 0.0770
95 185 225 210 260 0.193 0.0766
120 220 260 250 295 0.153 0.0743
150 250 290 280 335 0.124 0.0745
185 285 335 325 380 0.0991 0.0744
CERTIFICATIONS

 

95mm2 0.6/1kV building wire

95mm2 600/1000V single core wire

PACKAGING

 

95mm2 AS/NZS 5000.1 cable

Roll

95mm2 AS/NZS 1125 copper wire

Plastic Reel

1C x 95mm2 V90 PVC cable

Small Wooden Reel

APPLICATION

 

1 x 95 mm² building wire
Industrial Control Panel
95mm2 unsheathed copper cable
Renewable Energy Power Connection
95mm2 fixed wiring cable

Switchboard Wiring

 

CASE

 

95mm2 switchboard wiring cable

Adelaide Airport Switchboard Upgrade

95mm2 control panel wiring cable

Industrial Main Switchboard Power Distribution

95mm2 building wire supplier

Main Switchboard Flexible Cable Replacement

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

95mm2 building wire manufacturer
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

95mm2 V90 copper wire price
 
95mm2 V90 cable datasheet
 
Australian standard V90 building wire
 
New Zealand standard conduit wire
 
Australia New Zealand building wire
 
AS NZS 5000.1 1C PVC V90
 
GLOBAL CERTIFICATIONS

 

AS NZS 1125 copper building wire

CUSTOMER PHOTOS
 

V-90 insulation 600 1000 volt cable

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

conductor size 1mm2 to 185mm2 building wire
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

single core cable 1mm2 185mm2 range
1.0mm2 solid copper conductor 1/1.13 V90 cable
1.5mm2 stranded copper conductor 7/0.50 V90 cable
2.5mm2 solid copper conductor 1/1.78 V90 cable
2.5mm2 stranded copper conductor 7/0.67 V90 cable
4mm2 stranded copper conductor 7/0.85 V90 cable
6mm2 stranded copper conductor 7/1.04 V90 cable
10mm2 stranded copper conductor 7/1.35 V90 cable
16mm2 stranded copper conductor 7/1.70 V90 cable
25mm2 stranded copper conductor 19/1.35 V90 cable
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

35mm2 stranded copper conductor 19/1.53 V90 cable
FAQ

 

Can cable pulling lubricant be used?
Conduit wire pulling lubricant should be compatible with the V-90 PVC insulation and the conduit material. GERITEL WIRE recommends that the installer use a recognized electrical-cable lubricant, avoid unapproved oils or chemicals, and test compatibility when the product or site procedure is unusual.
Is solid or stranded wire easier to pull through conduit?
Stranded conduit wire is generally easier to route around bends than an equivalent solid conductor, but it is still Class 2 fixed-wiring cable rather than fine-stranded flex. GERITEL WIRE supplies the listed construction for each size and clearly separates the solid and stranded 2.5mm² options in order documents.
Should ferrules be used on Class 2 building wire?
Class 2 wire termination must match the terminal manufacturer's instructions. Ferrules may be appropriate for some devices but should not be assumed for every lug or screw terminal. GERITEL WIRE provides the strand construction so panel builders can choose approved ferrules, lugs and tooling for the actual equipment.
Which lugs are suitable for larger V90 conductors?
Copper cable lug selection should match conductor material, nominal cross-section, strand class, stud size and crimping system. GERITEL WIRE can confirm whether the ordered size is solid or Class 2 stranded and provide samples for termination trials when agreed before a large project order.

 

Hot Tags: 95mm2 1c copper building cable 600/1000v v-90, China 95mm2 1c copper building cable 600/1000v v-90 manufacturers, suppliers, factory

Send Inquiry