4x150+1x50E LSZH 3 Phase Neutral Earth Power Cable
Details:
·Standard: AS/NZS 5000.1;AS/NZS 3808; AS/NZS 4507
·Voltage: 0.6/1kV
·Conductor: Plain Annealed Copper (Class 5) to AS/NZS 1125
·Insulation: X-HF-110 (Natural)
·Sheath: HFS-110-TP UV Resistant (Orange)
·Flame Propagation: IEC 60332-3 cat A IEC 60332-1
·Green Star: PVC Free
Send Inquiry
Download
Description
Technical Parameters
Certification

Dongguan Greater Wire & Cable Co., Ltd. is one of the leading manufacturers and suppliers of 4x150+1x50e lszh 3 phase neutral earth power cable in China, also supports customized service. Please rest assured to wholesale durable 4x150+1x50e lszh 3 phase neutral earth power cable made in China here from our factory. If you have any enquiry about free sample, please feel free to email us.

 

4×150+1×50E 110°C elastomer cable

PRODUCT REAL SHOT

 

4×150+1×50E 110C elastomer cable
4×150+1×50E 4C+E cable
4×150+1×50E 4 core and earth cable

4×150+1×50E 4 core + earth cable

High-Capacity 4C+E Cable for Commercial and Public Infrastructure
The 4x150+1x50E 4C+E cable is a high-capacity flexible feeder for fixed 0.6/1kV distribution where a neutral and protective earth are both required. Its Class 5 copper construction can be considered as a 4C+E cable for hospitals when project specifications call for LSZH materials in protected electrical rooms and service risers. The same configuration is suitable as a 4C+E cable for airport terminals and other large facilities that distribute three-phase power to mixed downstream loads. X-HF-110 insulation and HFS-110-TP sheathing create a low fire hazard cable for public buildings with low-smoke, halogen-free and flame-retardant characteristics. GERITEL WIRE supplies SAA support, technical submittals, inspection options, custom marking and heavy-duty export drums.
PRODUCT SPECIFICATIONS

 

4×150+1×50E 3 phase neutral earth cable

Applications

 

Flexible single core X-HF-110 insulated and HFS-110-TP sheathed cable for mains, submains and subcircuits unenclosed, enclosed in conduit or in underground ducts for building and industrial plants where not subject to mechanical damage. Suitable where space is at a premium and/or where conditions of overload may occur.

SPECIFICATIONS
Approvals Suitable for fixed applications only in accordance with AS/NZS 3000+AS/NZS 5000.1
Behaviour in flame and fire: Flame propagation - AS/NZS IEC 60332-1
Temperature range

Maximum operating temperature: +110°C

Minimum operating temperature: -25°C

Minimum bending radius

Installed cables: 4D

During installation: 6D

Resistance to

Chemical exposure: OccasionaI

Mechanical impact: Light

Water exposure: Uccasional condensation

Solar radiation and weather exposure:Occasional

Cable design

Conductor: Flexible bunched annealed copper conductor to A5/NZ5 1125 (Class 5).

Insulation: X-HF-110 Colour:Natural

Sheath: HFS-110-TP Colour: Orange

Installation conditions

In free air

In conduit

In trench

In duct

Core x cross-

section

nx

mm²

Conductor Diameter

mm

Nominal insulation

thicknes

(mm)

Nominal

sheath

thickness
(mm)

Approx.

overall

diamete
(mm)

Approx.

weight

(kg/km)

phase

 

earth

 

phase

 

earth

 

4x10+1x4E 0.40 0.30 0.7 0.7 1.8 19.5 617
4x16+1x6E 0.40 0.30 0.7 0.7 1.8 21.8 868
4x25+1x6E 0.40 0.30 0.9 0.7 1.8 25.6 1245
4x35+1x10E 0.40 0.40 0.9 0.7 1.8 29.2 1694
4x50+1x16E 0.40 0.40 1.0 0.7 1.9 34.0 2376
4x70+1x25E 0.50 0.40 1.1 0.9 2.0 39.5 3316
4x95+1x25E 0.50 0.40 1.1 0.9 2.2 43.6 4208
4x120+1x35E 0.50 0.40 1.2 0.9 2.3 48.7 5343
4x150+1x50E 0.50 0.40 1.4 1.0 2.5 54.6 6720
4x185+1x70E 0.50 0.50 1.6 1.1 2.7 60.7 8283
4x240+1x95E 0.50 0.50 1.7 1.1 2.9 68.6 10802
mm²

Reactance

at 50Hz

(ohm/km)

Current Rating (A)

Electrical
Characteristics

Spaced

Touching surface

Metallic wiring

enclosure
in air

Underground

duct

one duct

Maximum DC

Resistance 20°C

Ω/km

10 0.0810 80 75 65 71 1.91
16 0.0779 106 99 84 91 1.21
25 0.0783 140 131 112 118 0.780
35 0.0761 173 162 137 143 0.554
50 0.0754 218 204 175 178 0.386
70 0.0744 273 255 217 217 0.272
95 0.0729 327 306 263 259 0.206
120 0.0723 387 360 306 298 0.161
150 0.0728 444 413 356 341 0.129
185 0.0730 505 470 402 381 0.106
240 0.0722 602 559 489 453 0.0801
CERTIFICATIONS

 

4×150+1×50E 3P+N+E cable

4×150+1×50E SAA cable

PACKAGING

 

4×150+1×50E SAA approved cable

Plastic Reel

4×150+1×50E X-HF-110 cable

Small Wooden Reel

4×150+1×50E HFS-110-TP cable

Large Wooden Reel

APPLICATION

 

4×150+1×50E LSZH cable
Industrial Equipment and Motor Power Supply
4×150+1×50E LFH cable
Switchboard and Distribution Panel Wiring
4×150+1×50E flexible power cable

Underground Cable Trench and Conduit Installation

 

CASE

 

4×150+1×50E Class 5 copper cable

Induction Melting Furnace Power System

4×150+1×50E 0.6/1kV cable

Mining Processing Plant MCC and Substation UpgradeModular Homes

4×150+1×50E mains cable

Steel Mill Walking Beam Furnace Electrical Installation

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

4×150+1×50E submains cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

4×150+1×50E feeder cable
 
4×150+1×50E switchboard cable
 
3P+N+E cable for industrial equipment
 
4C+E cable for equipment control circuits
 
three phase cable with neutral for control power
 
4 core earth cable for mixed three phase loads
 
GLOBAL CERTIFICATIONS

 

4C+E flexible cable for equipment connections

CUSTOMER PHOTOS
 

4C+E cable for machines requiring neutral

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

4C+E cable for three phase air conditioning
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

4C+E cable for HVAC systems
3 phase neutral earth cable for air conditioners
4C+E cable for chillers
4C+E cable for AHU systems
LSZH cable for mechanical plant rooms
4C+E cable for cooling towers
110C cable for building mechanical services
4C+E cable for ventilation equipment
three phase cable with neutral for HVAC controls
4C+E cable for EV charger installation
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

three phase EV charger cable with earth
FAQ

 

Does the neutral count as a loaded conductor for derating?
It can, depending on the load balance and harmonic content. In some applications the neutral may carry significant current, so a 4C+E neutral loading calculation should be considered rather than automatically assuming the neutral is unloaded. GERITEL WIRE provides conductor data; final derating remains with the electrical designer.
How do I calculate voltage drop on a long 4C+E feeder?
Voltage drop depends on current, length, conductor resistance, reactance, power factor and system arrangement. GERITEL WIRE can provide resistance and reactance values for a 4C+E voltage drop calculation so the designer can verify the selected size over the actual route length.
Do grouped 4C+E cables need derating?
Yes. Grouping can reduce heat dissipation, so current capacity should be corrected for the installation arrangement. GERITEL WIRE can provide technical inputs for 4C+E cable derating for grouped circuits, including cable size and relevant current-rating assumptions.
How is the reduced earth conductor checked?
The protective earth must satisfy the project's fault-current and protective-device requirements. A three phase cable sizing with neutral and reduced earth review therefore checks normal load in the four insulated cores and short-duration fault duty in the PE. GERITEL WIRE lists phase/neutral and earth sizes separately for this reason.

 

Hot Tags: 4x150+1x50e lszh 3 phase neutral earth power cable, China 4x150+1x50e lszh 3 phase neutral earth power cable manufacturers, suppliers, factory, 110 elastomer cables, 110 Single Core Elastomer Cables

Send Inquiry