4x16mm+1x6E SAA 4 Core And Earth LSZH Cable 110C

4x16mm+1x6E SAA 4 Core And Earth LSZH Cable 110C
Details:
·Standard: AS/NZS 5000.1;AS/NZS 3808; AS/NZS 4507
·Voltage: 0.6/1kV
·Conductor: Plain Annealed Copper (Class 5) to AS/NZS 1125
·Insulation: X-HF-110 (Natural)
·Sheath: HFS-110-TP UV Resistant (Orange)
·Flame Propagation: IEC 60332-3 cat A IEC 60332-1
·Green Star: PVC Free
Send Inquiry
Download
Description
Technical Parameters
Certification

Dongguan Greater Wire & Cable Co., Ltd. is one of the leading manufacturers and suppliers of 4x16mm+1x6e saa 4 core and earth lszh cable 110c in China, also supports customized service. Please rest assured to wholesale durable 4x16mm+1x6e saa 4 core and earth lszh cable 110c made in China here from our factory. If you have any enquiry about free sample, please feel free to email us.

 

4×16+1×6E 110°C elastomer cable

PRODUCT REAL SHOT

 

4×16+1×6E 110C elastomer cable
4×16+1×6E 4C+E cable
4×16+1×6E 4 core and earth cable

4×16+1×6E 4 core + earth cable

Flexible 3P+N+E Cable for HVAC and Building Services
The 4x16+1x6E 110C elastomer cable combines four insulated Class 5 copper cores with a reduced protective earth for flexible fixed power distribution. It is a practical 4C+E cable for HVAC systems where three-phase motors or compressors may operate alongside control or auxiliary circuits that require a neutral. The X-HF-110 insulated cores and HFS-110-TP sheath also support use as a three phase cable with neutral for HVAC controls in protected plant-room routes. Its low-smoke, halogen-free material system makes it a low fire hazard cable for switchrooms and occupied commercial facilities. GERITEL WIRE can provide SAA document matching, dimensional data, OEM sheath printing, project lengths and export drum identification.
PRODUCT SPECIFICATIONS

 

4×16+1×6E 3 phase neutral earth cable

Applications

 

Flexible single core X-HF-110 insulated and HFS-110-TP sheathed cable for mains, submains and subcircuits unenclosed, enclosed in conduit or in underground ducts for building and industrial plants where not subject to mechanical damage. Suitable where space is at a premium and/or where conditions of overload may occur.

SPECIFICATIONS
Approvals Suitable for fixed applications only in accordance with AS/NZS 3000+AS/NZS 5000.1
Behaviour in flame and fire: Flame propagation - AS/NZS IEC 60332-1
Temperature range

Maximum operating temperature: +110°C

Minimum operating temperature: -25°C

Minimum bending radius

Installed cables: 4D

During installation: 6D

Resistance to

Chemical exposure: OccasionaI

Mechanical impact: Light

Water exposure: Uccasional condensation

Solar radiation and weather exposure:Occasional

Cable design

Conductor: Flexible bunched annealed copper conductor to A5/NZ5 1125 (Class 5).

Insulation: X-HF-110 Colour:Natural

Sheath: HFS-110-TP Colour: Orange

Installation conditions

In free air

In conduit

In trench

In duct

Core x cross-

section

nx

mm²

Conductor Diameter

mm

Nominal insulation

thicknes

(mm)

Nominal

sheath

thickness
(mm)

Approx.

overall

diamete
(mm)

Approx.

weight

(kg/km)

phase

 

earth

 

phase

 

earth

 

4x10+1x4E 0.40 0.30 0.7 0.7 1.8 19.5 617
4x16+1x6E 0.40 0.30 0.7 0.7 1.8 21.8 868
4x25+1x6E 0.40 0.30 0.9 0.7 1.8 25.6 1245
4x35+1x10E 0.40 0.40 0.9 0.7 1.8 29.2 1694
4x50+1x16E 0.40 0.40 1.0 0.7 1.9 34.0 2376
4x70+1x25E 0.50 0.40 1.1 0.9 2.0 39.5 3316
4x95+1x25E 0.50 0.40 1.1 0.9 2.2 43.6 4208
4x120+1x35E 0.50 0.40 1.2 0.9 2.3 48.7 5343
4x150+1x50E 0.50 0.40 1.4 1.0 2.5 54.6 6720
4x185+1x70E 0.50 0.50 1.6 1.1 2.7 60.7 8283
4x240+1x95E 0.50 0.50 1.7 1.1 2.9 68.6 10802
mm²

Reactance

at 50Hz

(ohm/km)

Current Rating (A)

Electrical
Characteristics

Spaced

Touching surface

Metallic wiring

enclosure
in air

Underground

duct

one duct

Maximum DC

Resistance 20°C

Ω/km

10 0.0810 80 75 65 71 1.91
16 0.0779 106 99 84 91 1.21
25 0.0783 140 131 112 118 0.780
35 0.0761 173 162 137 143 0.554
50 0.0754 218 204 175 178 0.386
70 0.0744 273 255 217 217 0.272
95 0.0729 327 306 263 259 0.206
120 0.0723 387 360 306 298 0.161
150 0.0728 444 413 356 341 0.129
185 0.0730 505 470 402 381 0.106
240 0.0722 602 559 489 453 0.0801
CERTIFICATIONS

 

4×16+1×6E 3P+N+E cable

4×16+1×6E SAA cable

PACKAGING

 

4×16+1×6E SAA approved cable

Plastic Reel

4×16+1×6E X-HF-110 cable

Small Wooden Reel

4×16+1×6E HFS-110-TP cable

Large Wooden Reel

APPLICATION

 

4×16+1×6E LSZH cable
Industrial Equipment and Motor Power Supply
4×16+1×6E LFH cable
Switchboard and Distribution Panel Wiring
4×16+1×6E flexible power cable

Underground Cable Trench and Conduit Installation

 

CASE

 

4×16+1×6E Class 5 copper cable

Induction Melting Furnace Power System

4×16+1×6E 0.6/1kV cable

Mining Processing Plant MCC and Substation UpgradeModular Homes

4×16+1×6E mains cable

Steel Mill Walking Beam Furnace Electrical Installation

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

4×16+1×6E submains cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

4×16+1×6E feeder cable
 
4×16+1×6E switchboard cable
 
0.6/1kV 4 core and earth cable
 
600/1000V 4C+E cable
 
SAA 4C+E elastomer cable
 
SAA approved 4C+E cable
 
GLOBAL CERTIFICATIONS

 

SAA approved 4 core and earth cable

CUSTOMER PHOTOS
 

SAA approved 110°C multicore cable

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

Australian standard 4C+E cable
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

Australian standard 4 core and earth cable
AS/NZS 5000.1 4C+E cable
AS/NZS 5000.1 4 core and earth cable
AS/NZS 1125 Class 5 multicore cable
X-HF-110 4C+E cable
110C multicore elastomer cable
X-HF-110 4 core and earth cable
X-HF-110 flexible multicore cable
HFS-110-TP 4C+E cable
HFS-110-TP sheathed multicore cable
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

X-HF-110 HFS-110-TP multicore cable
FAQ

 

Why is the earth conductor smaller than the four main cores?
The protective earth is sized for fault-current duty rather than normal continuous load current, so many Australian 4C+E constructions use a reduced earth. A 4C+E cable with reduced earth must still satisfy the project's fault-clearing and earthing design. GERITEL WIRE always shows the format as 4x…+1x…E so the earth size is visible before order confirmation.
Are all four insulated cores the same cross-section?
For the listed GERITEL WIRE 4C+E range, the four insulated current-carrying cores are the same nominal cross-section and the earth may be smaller. This 4C+E cable construction makes it suitable for L1/L2/L3/N distribution while keeping the PE size separately defined. GERITEL WIRE reproduces the exact construction on drawings, drum labels and packing lists.
Is the cable flexible or rigid?
The conductor is designed as fine-stranded flexible copper rather than a rigid Class 2 construction. A Class 5 copper 4C+E cable is easier to route around switchboards, risers and plant rooms, especially in larger sizes. GERITEL WIRE can provide outer diameter, approximate weight and bending information to help contractors plan installation.
What other names do overseas buyers use for this product?
Common search terms include 4C+E, 4 Core + Earth, 4 Core and Earth, Flexible 110C, X-HF-110, LFH, LSZH and Three Phase + Neutral + Earth. GERITEL WIRE uses the formal 4C+E 110°C elastomer cable description together with these market aliases so buyers can identify the correct product without losing technical accuracy.

 

Hot Tags: 4x16mm+1x6e saa 4 core and earth lszh cable 110c, China 4x16mm+1x6e saa 4 core and earth lszh cable 110c manufacturers, suppliers, factory, 110 elastomer cables, 110 Single Core Elastomer Cables

Send Inquiry