·Conductor: Annealed copper conductor
·Insulation: V-90 PVC (Polyvinyl chloride)
·Sheath: 5V-90 PVC (Polyvinyl chloride)
·Sheath Colour: Black,Orange
·Core Identification: 1 Core (choice) Red, White, Light Blue, Black 2 Cores: Brown, Light Blue 3 Cores: Brown, Light Blue, Green/Yellow 4 Cores: Brown,Light Blue, White, Green/Yellow 5 Cores: Brown, Light Blue,White,Orange,Green/Yellow
·STANDARDS: AS/NZS 5000.1, AS/NZS 3191, AS/NZS 1125
·Rated Voltage Uo/U:0.6/1kV
·Temperature Rating:Maximum continuous operating temperature: 90°C
·Minimum Bending Radius:Flexed: 6x Overall diameter
Send Inquiry
Download
Description
Technical Parameters
Certification

3 core 16mm2 heavy duty flexible cable

PRODUCT REAL SHOT

 

3 core 16mm² heavy duty flexible cord
16mm2 3 core V90 flexible cable
3C x 16mm2 V90 PVC flex cable

3 x 16mm2 0.6/1kV flexible cable

Industrial Flexible Power Cable for Three-Phase Motors and High-Load Equipment
The 16mm² size is suited to industrial equipment connections where higher conductor capacity and flexible routing are both important. This 16mm2 heavy duty flexible cable is offered in 3- and 4-core configurations, using annealed flexible copper, V-90 PVC insulation and a 5V-90 PVC sheath for 0.6/1kV service. A three phase motor flexible cable in the appropriate core arrangement can simplify routing between panels, motors and machine sections. The same range also serves as a V90 industrial machinery cable for protected plant equipment that matches the cable rating. GERITEL WIRE can confirm conductor data, overall diameter, core colours, marking, documents and export packaging.
PRODUCT SPECIFICATIONS

 

16 sq mm 3 core heavy duty flex cable

Applications

 

Heavy Duty flexible cords for installation in switchboards and control panels especially in tight routes and confined spaces,and where flexibility is needed for hinged panels. Suitable for small industrial and commercial equipment requiring three-phase power. Can be used for extension leads in sizes 1mm² and above. 3 core and above include earth core for three-phase/single phase supply such as equipment with three-phase motor and single phase pilot lights like industrial sweepers, vacuum cleaners and welders. Also suitable for use with double insulated appliances where the cord is subject to higher mechanical stress, in damp and wet conditions.

SPECIFICATIONS
Rated Voltage Uo/U 0.6/1kV
Temperature Rating Maximum continuous operating temperature: 90°C
Minimum Bending Radius 6x overall diameter
Conductor Annealed copper conductor
Insulation V-90 PVC (Polyvinyl chloride)
Sheath 5V-90 PVC (Polyvinyl chloride)
Sheath Colour

Black, Orange

Core Identification

1 Core (choice) Red, White, Light Blue, Black

2 Cores: Brown, Light Blue

3 Cores: Brown, Light Blue, Green/Yellow

4 Cores: Brown,Light Blue, White, Green/Yellow

5 Cores: Brown, Light Blue,White,Orange,Green/Yellow

STANDARDS AS/NZS 5000.1, AS/NZS 3191, AS/NZS 1125
NO.OF CORES

NOMINALCONDUCTOR
SIZE

mm

NOMINAL

INSULATION

THICKNESS

mm

NOMINAL

OUTER SHEATH

THICKNESS

mm

NOMINAL

OVERALL

DIAMETER

mm

NOMINAL
WEIGHT
kg/100m
2 0.75 0.8 1.3 8.2 8.4
2 1.0 0.8 1.3 8.6 9.3
2 1.5 0.8 1.5 9.5 12
2 2.5 0.9 1.7 11.2 17
2 4 1.0 1.8 13 25
3 0.75 0.8 1.4 8.8 10
3 1.0 0.8 1.4 9.2 11
3 1.5 0.8 1.6 10.2 15
3 2.5 0.9 1.8 12.1 21
3 4 1.0 1.9 13.9 30
3 6 1.0 2.9 16.0 44
3 10 1.0 3.1 20.5 69
3 16 1.0 3.3 24.1 90
3 25 1.2 3.7 29.4 140
3 35 1.2 4.0 32.5 181
3 50 1.4 4.4 37.7 241
4 0.75 0.8 1.5 9.8 12
4 1.0 0.8 1.5 10.2 14
4 1.5 0.8 1.7 11.3 18
4 2.5 0.9 1.9 13.3 26
4 4 1.0 2.0 15.4 38
4 6 1.0 3.0 17.6 54
4 10 1.0 3.3 22.6 85
4 16 1.0 3.5 26.1 122
4 25 1.2 3.9 32.0 191
4 35 1.2 4.2 35.3 246
4 50 1.4 4.7 41.2 332
4 70 1.4 5.1 48.3 460
4 95 1.6 5.7 53.3 577
4 120 1.6 6.1 60.0 731
5 0.75 0.8 1.6 10.8 15
5 1.0 0.8 1.6 11.2 17
5 1.5 0.8 1.8 12.4 21
5 2.5 0.9 2.0 14.6 30
5 4 1.0 2.2 17.1 46

NOMINAL CONDUCTOR

SIZE
mm

CURRENT CARRYING

CAPACITY
A

MAXIMUM DC

RESSTANCE AT 20 °C

Ohm/km

MAXIMUM AC

RESISTANCE AT 90°C
Ohm/km

SINGLE PHASE

VOLTAGE DROP

MV/A.m

0.5 3 39.0 49.7 99.4
0.75 7.5 26.0 33.2 66.3
1.0 10 19.5 24.9 49.8
1.5 16 13.3 17 34
2.5 20 7.98 10.2 20.3
4.0 25 4.95 6.31 12.6
CERTIFICATIONS

 

3 core 16mm2 orange flexible cable

16mm2 3 core Class 5 flexible cable

PACKAGING

 

2C+E 16mm2 heavy duty flexible cable

Roll

V90 3 core 16mm2 PVC flexible cable 0.6/1kV

Plastic Reel

AS/NZS 3191 V90 PVC heavy duty flexible cord 0.6/1kV

Small Wooden Reel

APPLICATION

 

AS/NZS 5000.1 V90 PVC heavy duty flexible cable
Control Panels & Switchboards
V90 PVC insulation 5V90 PVC sheath heavy duty cable
Industrial Vacuum & Wet-Area Equipment
90 degree PVC heavy duty flexible cord

Three-Phase Motor & Pump Equipment

 

CASE

 

6x overall diameter bending radius flexible cord

Bayswater Power Station Crane Drive System Upgrade

black V90 heavy duty flexible cable 0.6/1kV

Brewery Control System Upgrade

orange V90 heavy duty flexible cable 0.6/1kV

North Esk Irrigation Pump Station

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

brown blue green yellow heavy duty flexible cord
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

Class 5 copper V90 PVC heavy duty flex cable
 
round multicore PVC heavy duty flexible cable
 
what colours are used in heavy duty flexible cord cores
 
how many cores are needed for three phase flexible cable
 
is V90 PVC cable suitable for industrial machinery
 
is heavy duty flexible cable suitable for continuous flexing
 
GLOBAL CERTIFICATIONS

 

0.6 1kV flexible cable

CUSTOMER PHOTOS
 

1kV flexible cord

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

can heavy duty flexible cord be used outdoors
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

can V90 heavy duty cable be used in wet areas
can heavy duty flexible cable be used for three phase motors
can heavy duty flexible cable be used for welders
0.6/1kV heavy duty flexible cable
can heavy duty flexible cable be used in control panels
can heavy duty flexible cord be used in switchboards
orange vs black heavy duty flexible cable
4 core vs 5 core heavy duty flexible cable
3 core vs 4 core heavy duty flexible cable
V90 vs V90HT flexible cable
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

V90 vs 5V90 PVC cable
FAQ

 

What does 3C+E mean?
3C+E normally describes three circuit conductors plus one protective earth conductor, giving four cores in total. GERITEL WIRE can provide 3C+E Heavy Duty Flexible Cord options for suitable three-phase equipment and confirm conductor size, core colours and overall dimensions. If neutral is also required, the customer should specify that because the circuit may need a different core count.
Can you provide the cable overall diameter?
Yes. Overall diameter varies significantly with conductor size and number of cores, so it should be checked for every configuration. GERITEL WIRE can provide nominal OD data for a Heavy Duty Multicore Flexible Cable to help customers select glands, cable entries, trays, conduits and strain-relief hardware before placing the order.
Which core count should I choose for single-phase equipment?
Single-phase equipment commonly needs active and neutral, with protective earth added where the equipment is not double-insulated. GERITEL WIRE can help identify whether a 2 Core V90 Flexible Cord or a 2C+E construction better matches the wiring diagram. Final circuit design and earthing requirements should be confirmed by the equipment engineer or qualified electrician.
Which cable should I use for three-phase equipment without neutral?
A common arrangement is three phase conductors plus protective earth, often described as 3C+E or four core. GERITEL WIRE can supply a Three Phase Flexible Cable in the available conductor sizes and confirm phase and earth colours. Tell us the motor voltage, current, lead length and whether any auxiliary circuits are present before final size selection.

 