25mm2 Heavy Duty Flex Cable 0.6/1kV V90 PVC 3–4 Core

25mm2 Heavy Duty Flex Cable 0.6/1kV V90 PVC 3–4 Core
Details:
·Conductor: Annealed copper conductor
·Insulation: V-90 PVC (Polyvinyl chloride)
·Sheath: 5V-90 PVC (Polyvinyl chloride)
·Sheath Colour: Black,Orange
·Core Identification: 1 Core (choice) Red, White, Light Blue, Black 2 Cores: Brown, Light Blue 3 Cores: Brown, Light Blue, Green/Yellow 4 Cores: Brown,Light Blue, White, Green/Yellow 5 Cores: Brown, Light Blue,White,Orange,Green/Yellow
·STANDARDS: AS/NZS 5000.1, AS/NZS 3191, AS/NZS 1125
·Rated Voltage Uo/U:0.6/1kV
·Temperature Rating:Maximum continuous operating temperature: 90°C
·Minimum Bending Radius:Flexed: 6x Overall diameter
Send Inquiry
Download
Description
Technical Parameters
Certification

3 core 25mm2 heavy duty flexible cable

PRODUCT REAL SHOT

 

3 core 25mm² heavy duty flexible cord
25mm2 3 core V90 flexible cable
3C x 25mm2 V90 PVC flex cable

3 x 25mm2 0.6/1kV flexible cable

AS/NZS Heavy Duty Flexible Cable for Large Industrial Equipment Connections
For larger industrial loads, the 25mm² range provides a flexible multicore option in 3- and 4-core constructions. Buyers searching for a 25mm2 multicore flexible cable can compare the available circuit arrangements on one size-specific page without duplicate listings. It suits protected equipment interconnection power cable duties where flexible routing is required between panels, machinery and powered sections. Annealed stranded copper, V-90 PVC insulation and a 5V-90 PVC sheath form a robust Class 5 V90 power flex construction rated 0.6/1kV. GERITEL WIRE supports specification matching, dimensions, core identification, OEM marking, technical documents and export packaging.
PRODUCT SPECIFICATIONS

 

25 sq mm 3 core heavy duty flex cable

Applications

 

Heavy Duty flexible cords for installation in switchboards and control panels especially in tight routes and confined spaces,and where flexibility is needed for hinged panels. Suitable for small industrial and commercial equipment requiring three-phase power. Can be used for extension leads in sizes 1mm² and above. 3 core and above include earth core for three-phase/single phase supply such as equipment with three-phase motor and single phase pilot lights like industrial sweepers, vacuum cleaners and welders. Also suitable for use with double insulated appliances where the cord is subject to higher mechanical stress, in damp and wet conditions.

SPECIFICATIONS
Rated Voltage Uo/U 0.6/1kV
Temperature Rating Maximum continuous operating temperature: 90°C
Minimum Bending Radius 6x overall diameter
Conductor Annealed copper conductor
Insulation V-90 PVC (Polyvinyl chloride)
Sheath 5V-90 PVC (Polyvinyl chloride)
Sheath Colour

Black, Orange

Core Identification

1 Core (choice) Red, White, Light Blue, Black

2 Cores: Brown, Light Blue

3 Cores: Brown, Light Blue, Green/Yellow

4 Cores: Brown,Light Blue, White, Green/Yellow

5 Cores: Brown, Light Blue,White,Orange,Green/Yellow

STANDARDS AS/NZS 5000.1, AS/NZS 3191, AS/NZS 1125
NO.OF CORES

NOMINALCONDUCTOR
SIZE

mm

NOMINAL

INSULATION

THICKNESS

mm

NOMINAL

OUTER SHEATH

THICKNESS

mm

NOMINAL

OVERALL

DIAMETER

mm

NOMINAL
WEIGHT
kg/100m
2 0.75 0.8 1.3 8.2 8.4
2 1.0 0.8 1.3 8.6 9.3
2 1.5 0.8 1.5 9.5 12
2 2.5 0.9 1.7 11.2 17
2 4 1.0 1.8 13 25
3 0.75 0.8 1.4 8.8 10
3 1.0 0.8 1.4 9.2 11
3 1.5 0.8 1.6 10.2 15
3 2.5 0.9 1.8 12.1 21
3 4 1.0 1.9 13.9 30
3 6 1.0 2.9 16.0 44
3 10 1.0 3.1 20.5 69
3 16 1.0 3.3 24.1 90
3 25 1.2 3.7 29.4 140
3 35 1.2 4.0 32.5 181
3 50 1.4 4.4 37.7 241
4 0.75 0.8 1.5 9.8 12
4 1.0 0.8 1.5 10.2 14
4 1.5 0.8 1.7 11.3 18
4 2.5 0.9 1.9 13.3 26
4 4 1.0 2.0 15.4 38
4 6 1.0 3.0 17.6 54
4 10 1.0 3.3 22.6 85
4 16 1.0 3.5 26.1 122
4 25 1.2 3.9 32.0 191
4 35 1.2 4.2 35.3 246
4 50 1.4 4.7 41.2 332
4 70 1.4 5.1 48.3 460
4 95 1.6 5.7 53.3 577
4 120 1.6 6.1 60.0 731
5 0.75 0.8 1.6 10.8 15
5 1.0 0.8 1.6 11.2 17
5 1.5 0.8 1.8 12.4 21
5 2.5 0.9 2.0 14.6 30
5 4 1.0 2.2 17.1 46

NOMINAL CONDUCTOR

SIZE
mm

CURRENT CARRYING

CAPACITY
A

MAXIMUM DC

RESSTANCE AT 20 °C

Ohm/km

MAXIMUM AC

RESISTANCE AT 90°C
Ohm/km

SINGLE PHASE

VOLTAGE DROP

MV/A.m

0.5 3 39.0 49.7 99.4
0.75 7.5 26.0 33.2 66.3
1.0 10 19.5 24.9 49.8
1.5 16 13.3 17 34
2.5 20 7.98 10.2 20.3
4.0 25 4.95 6.31 12.6
CERTIFICATIONS

 

3 core 25mm2 orange flexible cable

25mm2 3 core Class 5 flexible cable

PACKAGING

 

2C+E 25mm2 heavy duty flexible cable

Roll

V90 3 core 25mm2 PVC flexible cable 0.6/1kV

Plastic Reel

what colours are used in heavy duty flexible cord cores

Small Wooden Reel

APPLICATION

 

how many cores are needed for three phase flexible cable
Control Panels & Switchboards
how flexible is Class 5 copper cable
Industrial Vacuum & Wet-Area Equipment
is V90 PVC cable suitable for industrial machinery

Three-Phase Motor & Pump Equipment

 

CASE

 

is heavy duty flexible cable suitable for continuous flexing

Bayswater Power Station Crane Drive System Upgrade

can heavy duty flexible cord be used outdoors

Brewery Control System Upgrade

can V90 heavy duty cable be used in wet areas

North Esk Irrigation Pump Station

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

can heavy duty flexible cable be used for three phase motors
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

can heavy duty flexible cable be used for welders
 
can V90 flexible cable be used for extension leads
 
can heavy duty flexible cable be used in control panels
 
can heavy duty flexible cord be used in switchboards
 
orange vs black heavy duty flexible cable
 
4 core vs 5 core heavy duty flexible cable
 
GLOBAL CERTIFICATIONS

 

3 core vs 4 core heavy duty flexible cable

CUSTOMER PHOTOS
 

V90 vs V90HT flexible cable

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

V90 vs 5V90 PVC cable
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

AS/NZS 3191 vs AS/NZS 5000.1 flexible cable
heavy duty PVC flexible cable vs H07RN-F rubber cable
0.6/1kV heavy duty cord vs 250/440V ordinary duty cord
heavy duty flexible cord vs ordinary duty flexible cord
what is 5V90 PVC sheath
what does V90 mean on heavy duty cable
what is V90 heavy duty flexible cable
what is heavy duty flexible cord
heavy duty flexible cord technical quotation
heavy duty flexible cable export supplier
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

heavy duty flexible cable reel
FAQ

 

Which cable should I use if three-phase equipment also needs neutral?
If the circuit needs L1, L2, L3, neutral and protective earth, a five-core arrangement is typically required. GERITEL WIRE can review the wiring diagram and supply a 5 Core Heavy Duty Flexible Cable where the requested conductor size is available. We recommend confirming all conductor functions before ordering because five cores can also be used for other control or auxiliary arrangements.
Is 0.75mm² available in Heavy Duty Flexible Cord?
Yes, 0.75mm² appears in heavy-duty V90 cord ranges, with the exact core combinations depending on the manufacturer and product family. GERITEL WIRE can confirm the available 0.75mm² Heavy Duty Flexible Cord configurations and provide OD and core-colour data so buyers can verify panel entries and termination space before ordering.
Can 1mm² Heavy Duty Flex be used for extension leads?
Overseas heavy-duty V90 product literature states that extension leads can use this cord in conductor sizes of 1mm² and above, subject to finished-lead requirements. GERITEL WIRE can supply 1mm² Heavy Duty Flexible Cable in suitable core arrangements, but the plug, socket, length, current rating and local assembly standard must also be checked.
When should I choose 1.5mm² instead of 1mm²?
The decision depends on load current, cable length, voltage drop, installation conditions and equipment terminals. A 1.5mm² Heavy Duty Flex Cable has a larger copper cross-section than 1mm² and may be preferred for higher load or longer leads. GERITEL WIRE can provide conductor data and dimensions so your engineer can compare the two sizes against the actual circuit.

 

Hot Tags: 25mm2 heavy duty flex cable 0.6/1kv v90 pvc 3–4 core, China 25mm2 heavy duty flex cable 0.6/1kv v90 pvc 3–4 core manufacturers, suppliers, factory

Send Inquiry