Three Core 1.9/3.6kV Aluminum MV Power Cable

Three Core 1.9/3.6kV Aluminum MV Power Cable
Details:
Compliance
• Conductor resistance AS/NZS 1125
• Insulation resistance AS/NZS 1429.1
• Voltage test AS/NZS 1429.1
Standard and References
• AS/NZS 1429.1
• AS/NZS 1125
• AS/NZS 3808
Send Inquiry
Download
Description
Technical Parameters
Certification
3C AL MV Cable

 

Three Core 1.9/3.6kV Aluminum MV Power Cable

During the production process, three core aluminum MV power cable undergoes rigorous tests to verify its ability to withstand various conditions. These tests ensure that the cable can effectively enhance its safety and reliability in actual applications.

 

 

Application

 

 

Three core 1.9/3.6kV aluminum MV power cable is widely used in medium capacity distribution networks that balance cost-effectiveness and reliability. Its 1.9/3.6kV rated voltage falls within the low-to-medium voltage range, making it ideal for local power distribution, power feeders, and medium-sized industrial equipment. It also serves lighting systems, pumping stations, HVAC systems, and small to medium production lines that don't require ultra-high transmission capacity.

MV cable application

 

Feature

 

AL 3C MV Cable

 

• Conductor: Stranded Compacted Circular aluminium conductor as per AS/NZS 1125

• Conductor Screen: Extruded Semi-conductive compound

• Insulation: XLPE

• Insulation Screen: Extruded Semi-conductive compound

• Longitudinal Water blocking : Water blocking tape above and below copper screen (Optional)

• Metallic Insulation Screen: Copper Wire Screen + helically applied copper tape

• binder tape / sheath over assembled cores

• Metallic Sheath: Lead Alloy (optional)

• Outer Sheath: Extruded Polyvinyl Chloride, Colour: Black

• Insect attack Protection: Polyamide Nylon (optional)

(Alternative Sheath: PVC + HDPE Outer Sheath or LSZH Outer sheath and parameters will change accordingly)

 

Certification

 

 

MV power cables have obtained SAA certification, with certification numbers: SAA242046 and SAA250307 (available on the certification website). SAA certified cables meet stringent Australian and international standards for conductor purity, insulation thickness, flame retardancy, and other aspects. The certification process is more than just a formal review; it undergoes a series of tests for electrical performance, mechanical strength, and long-term durability. The cables are guaranteed to operate stably and safely in high-voltage environments, eliminating the risk of cutting corners. Key components undergo rigorous verification, ensuring they are truly high-quality, proven cables.

SAA medium voltage cable

 

Package

 

sta power cable package

 

Factory

 

SAA cable factory

 

Our wires and cables are designed for power, construction, transportation, mining, industry, home, communications and other industries. With the rapid development of the global economy and the continuous construction of infrastructure, the demand for efficient, safe and environmentally friendly cable products is growing. Especially in the context of energy transformation and intelligent development, the cables in factories are gradually developing towards energy conservation, environmental protection, safety and high performance to meet market demand.

 

 
 
services we offer
01.

Full Cycle Logistics Support

We provide professional logistics support throughout the entire project lifecycle-from transportation plan planning and warehouse management to customs clearance coordination, transportation execution, and after-sales follow-up.

02.

Familiarity with International Standards

Our expertise in international wire and cable standards covers major regions, including Asia, Oceania, and the Americas. We can provide customers with products that meet local regulations and receive authoritative certifications.

03.

7×24 hour service response

We understand the importance of responsiveness. That's why our service team is available 24/7 to support your cable project needs, providing real-time communication and quick solutions to keep your operations running smoothly.

04.

One-stop purchasing experience

We deliver a one-stop solution for wire and cable sourcing - offering product consultation, sample support, certification documents, logistics planning, and after-sales follow-up - ensuring a hassle-free experience for every customer.

 

Case

 

Company cases

 

Partner

 

greater wire Partner

 

FAQ

 

Q: What applications are 3 core aluminum MV cables mainly used for?

A:  3 core aluminum MV power cables can be mainly used in power distribution systems. In the power distribution networks of cities and towns, MV power cables are used as distribution lines to connect substations and user terminals. They can effectively transmit medium voltage power to meet the needs of different users.

Q:  Are power cables suitable for use in marine environment?

A:  Power cables can be used in marine environments, but there are special requirements for cables. For example, waterproof and moisture-proof properties. In marine environments, cables need to have extremely high waterproof properties. Corrosion resistance. The salt content in marine environments is high, which is corrosive to cable metal materials. Mechanical strength. To prevent cables from being affected by water currents, waves or collisions in marine environments, the sheath and structure of the cable need to have good mechanical strength to withstand these physical pressures. UV resistance. Cables are partially exposed to the air on offshore platforms or offshore facilities, and need to have UV resistance to avoid damage to the cable sheath by sunlight. Anti-biological erosion. Organisms in the marine environment (such as marine microorganisms, shellfish, etc.) may attach to the surface of the cable. Anti-biological attachment components are added to the cable sheath to maintain its normal operation. Temperature and pressure adaptability. Since the temperature and pressure on the seabed may be relatively extreme, the cable needs to use materials that can withstand large temperature differences and high water pressure.

Q:  Can aluminum cable be used to power electric motors?

A: Aluminum conductor cables can be used to power motors, but it is necessary to ensure that the cable specifications meet the operating requirements of the motor. For example, voltage level, the voltage level of the motor should match the rated voltage of the cable. Current carrying capacity, the current carrying capacity of the cable must be sufficient to meet the needs of the motor. Conductor material, aluminum conductors are relatively light and have lower costs than copper conductors. Although the conductivity of aluminum is slightly lower than that of copper, it can also meet the power supply needs of the motor if the cross-sectional area of the cable is appropriately increased. Insulation performance, the insulation layer material of the cable must be resistant to high temperature and moisture and have good durability. Short-circuit and starting current, the current of the motor at startup is much higher than the normal operating current, so the cable must be able to withstand a short-term high current shock.

 

 

Hot Tags: three core 1.9/3.6kv aluminum mv power cable, China three core 1.9/3.6kv aluminum mv power cable manufacturers, suppliers, factory

3C AL MV Cable

AL 3C MV Cable

No. of
Cores
Core Cross
sectional
Area
Nominal Diameter
Under
metallic
screen
Under
metallic
screen
Overall
No.
mm2
mm
mm
mm
3 16 11.8 13.3 33.0
3 25 13.1 14.6 35.0
3 35 14.1 15.6 38.0
3 50 15.2 16.7 40.0
3 70 16.8 18.3 44.0
3 95 18.4 19.9 48.0
3 120 20 21.5 51.0
3 150 21.3 22.8 54.0
3 185 23 24.5 58.0
3 240 25.3 26.8 64.0
3 300 27.5 29.0 69.0
3 400 30.2 31.7 75.0
3 500 34 35.5 83.0
• Above mentioned parameters are based on 3k A/sec earth fault current capacity of copper screen
 
ELECTRICAL CHARACTERISTICS:
No.of Cores
Core Cross sectional Area
Max. DC Resistance at 20˚C
Max. AC Resistance at 90˚C
Approx. Capacitance
Approx. Inductance
Approx.

 Reactance

Continuous Current Rating
Buried direet in ground
In a buried duct
In Air 
No.
mm2
Ω/km
Ω/km
µF/km
mH/km
Ω/km
Amps
3 16 1.91 2.449 0.26 0.603 0.189 78 67 84
3 25 1.2 1.539 0.3 0.569 0.179 100 87 110
3 35 0.868 1.113 0.34 0.551 0.173 119 103 132
3 50 0.641 0.822 0.38 0.534 0.168 140 122 158
3 70 0.443 0.568 0.43 0.506 0.159 171 150 196
3 95 0.32 0.411 0.49 0.492 0.154 203 179 236
3 120 0.253 0.325 0.55 0.477 0.150 232 205 273
3 150 0.206 0.265 0.59 0.469 0.147 260 231 309
3 185 0.164 0.211 0.65 0.460 0.144 294 262 355
3 240 0.125 0.161 0.73 0.450 0.141 340 305 415
3 300 0.1 0.129 0.81 0.441 0.139 384 346 475
3 400 0.778 0.101 0.9 0.433 0.136 438 398 552
3 500 0.0605 0.079 0.93 0.427 0.134 505 460 646
*: Current Ratings are based on IEC 60502-2 & IEC 60287, Max. Conductor Temperature at 90℃, Ambient temperature at 30℃ in Air / at 20℃ in Ground, Thermal resistivity of Soil 1.5 k.m/W & for earthenware ducts 1.2k.m/W and Depth of Laying 0.8m.
Current rating de-rating factors for other than 30℃ ambient air temperature.
20 25 35 40 45 50 55 60
1.08 1.04 0.96 0.91 0.87 0.82 0.76 0.71

 

Current rating de-rating factors for other than 20℃ ground temperature.
10 15 25 30 35 40 45 50
1.07 1.04 0.96 0.93 0.89 0.85 0.80 0.76

 

No.of Cores
Core Cross sectional Area
Max. pulling tension on conductor
Charging Current per phase
Zero sequence impedance
Electric Stress at Conductor Screen
Short circuit rating of Phase conductor
No. mm² kN Amps/Km Ohms/Km kV/mm kA, I sec
3 16 0.8 0.16 3.61 1.3 1.4
3 25 1.25 0.18 2.70 1.2 2.3
3 35 1.75 0.2 2.27 1.2 3.1
3 50 2.5 0.23 1.98 1.1 4.5
3 70 3.5 0.26 1.73 1.1 6.2
3 95 4.75 0.29 1.57 1.1 8.5
3 120 6 0.33 1.48 1.1 10.7
3 150 7.5 0.35 1.42 1.1 13.4
3 185 9.25 0.39 1.37 1.1 16.5
3 240 12 0.44 1.32 1.0 21.4
3 300 15 0.48 1.29 1.0 26.8
3 400 20 0.54 1.26 1.0 35.5
3 500 25 0.56 1.24 0.9 44.7

 

MV Cable

MV cable 02