SAA Standard Type 240 1.1 To 11KV Coal Mine Cable

SAA Standard Type 240 1.1 To 11KV Coal Mine Cable
Details:
Standards
AS/NZS 1802:2003
AS/NZS 1125
AS/NZS 3808
AS/NZS 5000.1
Send Inquiry
Download
Description
Technical Parameters
Certification
mining cables

 

 
SAA Standard Type 240 1.1 to 11KV Coal Mine Cable
  • 3×Conductors: Flexible stranded tinned annealed copper conductor.
  • Conductor Screen: Semiconductive compound (for cables having a voltage rating of 3.3/3.3kV and above).
  • Insulation: EPR.
  • Insulation Screen: Semiconductive elastomer.
  • Composite Screen (earth conductor): Tinned annealed copper braiding interwove with polyester yarn.
  • 3×Interstitial Pilot: EPR covered flexible stranded tinned copper conductor.
  • Cradle Separator: Semiconductive PCP.
  • Sheath: Heavy duty PCP sheath. Heavy duty CPE/CSP sheath can be offered upon request.
  • Standards

    AS/NZS 1802:2003

    AS/NZS 1125

    AS/NZS 3808

    AS/NZS 5000.1

 

 

 

Application

 

 

Coal mine cable is mainly used for high-voltage power transmission in coal mines and other underground mines. It is used for power supply deep underground in mines to provide stable power support for mining equipment, ventilation systems, hoists, lighting systems, etc. It is suitable for transmitting mine power from the ground to underground equipment, such as various mining equipment, crushers, conveyor belts, drilling equipment, etc. in mines.

mining cable application

 

Feature

 

coal mine cable

 

Coal mine cable adopts a multi-layer structure and high-quality materials to ensure its excellent electrical performance and mechanical strength in harsh environments, and is particularly suitable for applications requiring high voltage levels (up to 11kV). The flexible stranded soldered annealed copper conductor gives the cable good conductivity and mechanical flexibility, making it particularly suitable for environments that require frequent bending or movement, such as power connections for equipment in mines. The use of high-quality materials such as EPR and semi-conductive elastomers has strong aging resistance, heat resistance, and abrasion resistance, extending the service life of the cable.

 

Certification

 

 

 

Coal mine cables are key power transmission tools used in mine operations and must meet strict safety and performance standards to ensure the safety and reliability of the working environment in the mine area. The cables have passed the SAA certification, which is an important safety certification for electrical products in Australia and New Zealand. It is designed to ensure that cables and other electrical equipment can operate stably and safely in high-risk environments. The coal mine cables have passed the SAA certification, which means that they have met Australia's strict safety requirements in terms of fire prevention, explosion prevention, corrosion resistance, high temperature resistance and mechanical shock resistance.

mining cable SAA certification

 

Package

 

coal mine cable package

 

Company Introduction

 

coal mine cable factory

 

Dongguan Greater Wire & Cable Co., Ltd. was established in 1995, is a professional wire and cable manufacturer. The company has advanced production equipment and production technology, complete testing equipment, and strong product technology. After years of hard work and the support of customers around the world, it has provided wires and cables to more than 90 countries around the world. The company has developed rapidly and won high honors and shares in the overseas market. The company has passed the ls09001 quality management system certification, the national high-tech enterprise certification, and the national specialized and new enterprise certification. The products have corresponding certifications for different countries, such as SAA, UL, BPS, CE ,CB, VDE and other certifications.

 

customer

 

wire and cable supplier

 

 

Partner

 

Greater Wire Partner

 

FAQ

 

 

 

 

Q: What is the difference between mining cables and ordinary cables?

A: The biggest difference between mining cables and ordinary cables is that mining cables need to cope with extremely harsh environmental conditions, such as high temperature, humidity, electrical load, corrosive substances, mechanical shock, fire risk, etc. Mining cables must have high safety, fire resistance, corrosion resistance, vibration resistance and electromagnetic interference protection to ensure that the power system in dangerous environments such as mines can operate stably and reliably. Ordinary cables are mainly used in general industrial, commercial, home and other environments, and the design and performance requirements are relatively low.

Q: What are the storage requirements for mining cables?

A: The storage requirements for mining cables are very strict, involving temperature and humidity, mechanical damage, chemical corrosion, fire prevention, and other aspects. The purpose is to ensure that the quality of the cable is not affected during storage and to ensure that it can meet the high safety requirements of special environments such as mines in actual use. Reasonable storage can effectively extend the service life of the cable and reduce the quality problems caused by improper storage of the cable.

 

 

Hot Tags: saa standard type 240 1.1 to 11kv coal mine cable, China saa standard type 240 1.1 to 11kv coal mine cable manufacturers, suppliers, factory, HO7V-K, orange circular cable, SPT 1 SPT 2 Wire, HO7Z K 90 LSOH, UL BPS Certificated THHN THWN Copper Building Wire, HO7V-R

Type 240 11 to 11KV mining cable

 

 

 

Nominal
Conductor
Area
Strand Size
Insulation
Thickness
Core Screen
Pilot Conductor
Thickness
of Sheath
Nominal
Overall
Diameter
Nominal
Weight
Strand Size
Area of
Screen
Strand Size
Thickness
of Covering
mm²
No/mm
mm
No/mm
mm²
No/mm
mm
mm
mm
kg/100m
Type 240.1
6 84/0.30 1.5 7/0.25 7.2 18/0.30 1.0 3.8 30.0 131
10 77/0.40 1.5 7/0.25 8.6 27/0.30 1.0 3.8 32.6 159
16 126/0.40 1.6 7/0.25 9.6 42/0.30 1.0 4.0 35.8 202
25 209/0.40 1.6 7/0.25 11.3 66/0.30 1.2 4.3 39.7 265
35 285/0.40 1.6 7/0.25 12.4 90/0.30 1.2 4.6 43.1 326
50 380/0.40 1.7 7/0.25 14.1 120/0.30 1.2 5.0 47.7 404
70 203/0.67 1.8 7/0.25 16.5 39/0.67 1.2 5.4 53.9 533
95 259/0.67 2.0 7/0.25 18.2 39/0.67 1.2 6.0 58.6 635
120 336/0.67 2.1 7/0.25 20.3 42/0.67 1.4 6.4 64.4 775
150 427/0.67 2.3 7/0.25 22.3 54/0.67 1.4 6.9 70.2 940
185 518/0.67 2.5 7/0.30 30.2 63/0.67 1.4 7.4 77.4 1150
240 672/0.67

2.8

7/0.30 33.6 77/0.67 1.6 8.2 86.0 1440
300 854/0.67 3.0 7/0.40 50.1 98/0.67 1.6 8.8 95.1 1810
Type 240.3
16 126/0.40 3.0 7/0.25 13.1 42/0.30 1.4 5.3 46.2 306
25 209/0.40 3.0 7/0.25 14.8 66/0.30 1.4 5.6 50.1 379
35 285/0.40 3.0 7/0.25 15.8 90/0.30 1.4 5.9 53.5 444
50 380/0.40 3.0 7/0.25 17.2 120/0.30 1.4 6.3 57.6 525
70 203/0.67 3.0 7/0.25 18.6 39/0.67 1.4 6.6 62.5 656
95 259/0.67 3.0 7/0.25 20.3 39/0.67 1.4 7.1 66.2 750
120 336/0.67 3.0 7/0.30 27.2 42/0.67 1.6 7.4 72.0 910
150 427/0.67 3.0 7/0.40 39.6 54/0.67 1.6 7.8 78.0 1115
185 518/0.67 3.0 7/0.40 42.2 63/0.67 1.8 8.2 83.4 1280
240 672/0.67 3.0 7/0.40 46.6 77/0.67 1.8 8.8 90.3 1540
300 854/0.67 3.0 7/0.50 63.2 98/0.67 1.8 9.4 98.4 1920
Type 240.6
16 126/0.40 5.0 7/0.25 17.2 42/0.30 1.4 6.4 57.3 440
25 209/0.40 5.0 7/0.25 18.6 66/0.30 1.4 6.7 61.2 521
35 285/0.40 5.0 7/0.25 18.6 90/0.30 1.6 7.0 64.6 593
50 380/0.40 5.0 7/0.25 21.3 120/0.30 1.6 7.3 68.5 685
70 203/0.67 5.0 7/0.25 23.4 39/0.67 1.6 7.7 73.7 830
95 259/0.67 5.0 7/0.30 29.4 39/0.67 1.6 8.1 77.8 954
120 336/0.67 5.0 7/0.30 31.7 42/0.67 1.6 8.5 83.1 1111
150 427/0.67 5.0 7/0.40 45.7 54/0.67 1.8 8.9 89.1 1335
185 518/0.67 5.0 7/0.40 48.4 63/0.67 1.8 9.3 94.5 1515
240 672/0.67 5.0 7/0.40 52.8 77/0.67 1.8 9.9 101.4 1810
300 854/0.67 5.0 7/0.50 71.5 98/0.67 1.8 10.4 109.3 2190
Type 240.11
25 209/0.40 7.6 7/0.25 23.7 66/0.30 2.0 8.1 75.6 752
35 285/0.40 7.6 7/0.30 30.2 90/0.30 2.0 8.4 79.7 860
50 380/0.40 7.6 7/0.30 31.7 120/0.30 2.0 8.7 83.6 961
70 203/0.67 7.6 7/0.30 34.1 39/0.67 2.0 9.1 88.8 1125
95 259/0.67 7.6 7/0.40 47.5 39/0.67 2.0 9.6 93.7 1300
120 336/0.67 7.6 7/0.40 51.0 42/0.67 2.2 9.9 98.8 1470
150 427/0.67 7.6 7/0.40 53.7 54/0.67 2.2 10.3 103.5 1659
185 518/0.67 7.6 7/0.40 57.2 63/0.67 2.2 10.7 108.8 1880

 

Send Inquiry