- 3×Conductors: Flexible stranded tinned annealed copper conductor.
- Conductor Screen: Semiconductive compound (for cables having a voltage rating of 3.3/3.3kV and above)
- Insulation: EPR
- Insulation Screen: Semiconductive elastomer
- Composite Screen (earth conductor): Tinned annealed copper braiding interwove with polyester yarn
- Cradle Separator: Semiconductive PCP
- 1×Central Extensible Pilot: EPR covered flexible stranded tinned copper conductor
- Sheath: Heavy-duty PCP sheath. Heavy duty CPE/CSP sheath can be offered upon request
Application
Mining cable is typically designed as a trailing cable, intended to follow the movement of mining equipment, providing power as machinery is repositioned at a mining site. Unlike reeled cables, which are designed to be repeatedly wound and unwound, trailing cables are more flexible and rugged, suitable for use in environments where equipment is frequently moved, towed or relocated. The cable can withstand frequent bending, twisting and pulling, which is common in mining operations where machinery needs to be relocated over rough terrain. The flexibility of mining cable ensures that it can easily move with the equipment, preventing damage and reducing the need for frequent repairs or replacements.

Feature

Mining cables feature flexible stranded tinned annealed copper conductors that ensure efficient power transmission while remaining flexible for easy handling and installation in mobile applications. The conductors are designed to withstand mechanical stress and environmental factors such as abrasion and shock, making them ideal for use in mining operations where the cables are constantly moving and operating in harsh conditions. The conductor shield is made of a semi-conducting compound, which helps prevent electrical interference and ensures safe and efficient operation of the power system. The insulation is made of EPR (ethylene propylene rubber) which offers excellent resistance to heat, moisture and electrical stress.
Certification
Mining cable has passed SAA (Australia and New Zealand Certification Agency) certification and complies with safety standards and regulations in Australia and New Zealand. This certification ensures the reliability and safety of mining cables in extreme environments, especially in dangerous conditions such as high temperature, humidity, and fire. SAA-certified mining cables can effectively resist external mechanical shock, chemical corrosion, and electrical failures to ensure the stable operation of the power system. The certification process includes rigorous testing to ensure that the cable can maintain good conductivity and durability under heavy loads, high temperatures, and harsh conditions, greatly improving the safety of power transmission in mining operations.

Package

Company Introduction

Greater Wire manufacturer's advanced cable factory has an intelligent and digital manufacturing environment. Through the seamless integration of cutting-edge technology, the factory successfully eliminates errors and defects that may occur in the traditional manual assembly process. The shift to digital manufacturing not only increases efficiency but also demonstrates our commitment to providing our customers with products of the highest reliability. The smart factory framework ensures a streamlined and error-free production process, minimizing the possibility of human-related variances and increasing previously unattainable precision. Accurate and automated inspection mechanism, the factory strictly adheres to quality control. Products are thoroughly inspected from the beginning to the final stage of the manufacturing process. Digital intelligent image detection and laser technologies are used to ensure that each product meets the strict standards set by our company. This commitment to quality extends to our inspection accuracy, with automated production equipment achieving an impressive accuracy of 0.002 mm, exceeding industry benchmarks.
customer

Partner

FAQ
Q: What is a mining cable?
Q: What is mineral cable used for?
Q: Why do they call it mining cable?
Durability and Safety:
Mining cables need to be robust and able to resist mechanical stress, chemical exposure, and high temperatures, making them essential in the mining industry.
Hot Tags: type 209 1.1 to 11kv mining cable, China type 209 1.1 to 11kv mining cable manufacturers, suppliers, factory, SAA Australia Flat 2C E Electrical TPS Cable, High Temp Ultra Flexible Silicone Insulated Wire, 2 3 4 5 Core Kabel H05VV F, Kabel H05RR F, solar cable, ul1007 hook up wire

|
Nominal
Conductor
Area
|
Strand Size
|
Insulation
Thickness
|
Core Screen
|
Pilot Conductor
|
Thickness
of Sheath
|
Nominal
Overall
Diameter
|
Nominal
Weight
|
||
|
Strand Size
|
Area of
Screen
|
Strand Size
|
Thickness
of Covering
|
||||||
|
mm²
|
No/mm
|
mm
|
No/mm
|
mm²
|
No/mm
|
mm
|
mm
|
mm
|
kg/100m
|
|
Type 209.1
|
|||||||||
| 6 | 84/0.30 | 1.5 | 7/0.25 | 7.2 | 24/0.20 | 0.8 | 3.8 | 30.0 | 129 |
| 10 | 77/0.40 | 1.5 | 7/0.25 | 8.6 | 24/0.20 | 0.8 | 3.8 | 32.6 | 157 |
| 16 | 126/0.40 | 1.6 | 7/0.25 | 9.6 | 24/0.20 | 0.8 | 4.0 | 35.8 | 197 |
| 25 | 209/0.40 | 1.6 | 7/0.25 | 11.3 | 24/0.20 | 0.8 | 4.3 | 39.7 | 255 |
| 35 | 285/0.40 | 1.6 | 7/0.25 | 12.4 | 24/0.20 | 0.8 | 4.6 | 43.1 | 312 |
| 50 | 380/0.40 | 1.7 | 7/0.25 | 14.1 | 40/0.20 | 0.8 | 5.0 | 47.7 | 386 |
| 70 | 203/0.67 | 1.8 | 7/0.25 | 16.5 | 40/0.20 | 0.8 | 5.4 | 52.8 | 503 |
| 95 | 259/0.67 | 2.0 | 7/0.25 | 18.2 | 40/0.20 | 0.8 | 6.0 | 58.6 | 605 |
| 120 | 336/0.67 | 2.1 | 7/0.25 | 20.3 | 40/0.20 | 0.8 | 6.4 | 64.4 | 741 |
| 150 | 427/0.67 | 2.3 | 7/0.25 | 22.3 | 40/0.20 | 0.8 | 6.9 | 70.2 | 896 |
| 185 | 518/0.67 | 2.5 | 7/0.30 | 30.2 | 40/0.20 | 0.8 | 7.4 | 77.4 | 1092 |
| 240 | 672/0.67 |
2.8 |
7/0.30 | 33.6 | 40/0.20 | 0.8 | 8.2 | 86.0 | 1365 |
| 300 | 854/0.67 | 3.0 | 7/0.40 | 50.1 | 40/0.20 | 0.8 | 8.8 | 95.1 | 1715 |
|
Type 209.3
|
|||||||||
| 16 | 126/0.40 | 3.0 | 7/0.25 | 13.1 | 24/0.20 | 0.8 | 5.3 | 46.2 | 301 |
| 25 | 209/0.40 | 3.0 | 7/0.25 | 14.8 | 24/0.20 | 0.8 | 5.6 | 50.1 | 369 |
| 35 | 285/0.40 | 3.0 | 7/0.25 | 15.8 | 24/0.20 | 0.8 | 5.9 | 53.5 | 431 |
| 50 | 380/0.40 | 3.0 | 7/0.25 | 17.2 | 40/0.20 | 0.8 | 6.3 | 57.6 | 507 |
| 70 | 203/0.67 | 3.0 | 7/0.25 | 18.6 | 40/0.20 | 0.8 | 6.6 | 62.5 | 624 |
| 95 | 259/0.67 | 3.0 | 7/0.25 | 20.3 | 40/0.20 | 0.8 | 7.1 | 66.2 | 719 |
| 120 | 336/0.67 | 3.0 | 7/0.30 | 27.2 | 40/0.20 | 0.8 | 7.4 | 72.0 | 876 |
| 150 | 427/0.67 | 3.0 | 7/0.40 | 39.6 | 40/0.20 | 0.8 | 7.8 | 78.0 | 1072 |
| 185 | 518/0.67 | 3.0 | 7/0.40 | 42.2 | 40/0.20 | 0.8 | 8.2 | 83.4 | 1236 |
| 240 | 672/0.67 | 3.0 | 7/0.40 | 46.6 | 40/0.20 | 0.8 | 8.8 | 90.3 | 1500 |
| 300 | 854/0.67 | 3.0 | 7/0.50 | 63.2 | 40/0.20 | 0.8 | 9.4 | 98.4 | 1840 |
|
Type 209.6
|
|||||||||
| 16 | 126/0.40 | 5.0 | 7/0.25 | 17.2 | 24/0.20 | 0.8 | 6.4 | 57.3 | 435 |
| 25 | 209/0.40 | 5.0 | 7/0.25 | 18.6 | 24/0.20 | 0.8 | 6.7 | 61.2 | 512 |
| 35 | 285/0.40 | 5.0 | 7/0.25 | 18.6 | 40/0.20 | 0.8 | 7.0 | 64.6 | 582 |
| 50 | 380/0.40 | 5.0 | 7/0.25 | 21.3 | 40/0.20 | 0.8 | 7.3 | 68.5 | 668 |
| 70 | 203/0.67 | 5.0 | 7/0.25 | 23.4 | 40/0.20 | 0.8 | 7.7 | 73.7 | 799 |
| 95 | 259/0.67 | 5.0 | 7/0.30 | 29.4 | 40/0.20 | 0.8 | 8.1 | 77.8 | 935 |
| 120 | 336/0.67 | 5.0 | 7/0.30 | 31.7 | 40/0.20 | 0.8 | 8.5 | 83.1 | 1090 |
| 150 | 427/0.67 | 5.0 | 7/0.40 | 45.7 | 40/0.20 | 0.8 | 8.9 | 89.1 | 1310 |
| 185 | 518/0.67 | 5.0 | 7/0.40 | 48.4 | 40/0.20 | 0.8 | 9.3 | 94.5 | 1480 |
| 240 | 672/0.67 | 5.0 | 7/0.40 | 52.8 | 40/0.20 | 0.8 | 9.9 | 101.4 | 1750 |
| 300 | 854/0.67 | 5.0 | 7/0.50 | 71.5 | 40/0.20 | 0.8 | 10.4 | 109.3 | 2120 |
|
Type 209.11
|
|||||||||
| 25 | 209/0.40 | 7.6 | 7/0.25 | 23.7 | 24/0.20 | 0.8 | 8.1 | 75.6 | 750 |
| 35 | 285/0.40 | 7.6 | 7/0.39 | 30.2 | 24/0.20 | 0.8 | 8.4 | 79.7 | 858 |
| 50 | 380/0.40 | 7.6 | 7/0.30 | 31.7 | 40/0.20 | 0.8 | 8.7 | 83.6 | 960 |
| 70 | 203/0.67 | 7.6 | 7/0.30 | 34.1 | 40/0.20 | 0.8 | 9.1 | 88.8 | 1093 |
| 95 | 259/0.67 | 7.6 | 7/0.40 | 47.5 | 40/0.20 | 0.8 | 9.6 | 93.7 | 1267 |
| 120 | 336/0.67 | 7.6 | 7/0.40 | 51.0 | 40/0.20 | 0.8 | 9.9 | 98.8 | 1436 |
| 150 | 427/0.67 | 7.6 | 7/0.40 | 53.7 | 40/0.20 | 0.8 | 10.3 | 103.5 | 1614 |
| 185 | 518/0.67 | 7.6 | 7/0.40 | 57.2 | 40/0.20 | 0.8 | 10.7 | 108.8 | 1830 |