Details:
Standards
AS/NZS 1802:2003
AS/NZS 1125
AS/NZS 3808
AS/NZS 5000.1
Send Inquiry
Download
Description
Technical Parameters
Certification
mining cables

 

 
Type 209 1.1 to 11KV Mining Cable
  • 3×Conductors: Flexible stranded tinned annealed copper conductor.
  • Conductor Screen: Semiconductive compound (for cables having a voltage rating of 3.3/3.3kV and above)
  • Insulation: EPR
  • Insulation Screen: Semiconductive elastomer
  • Composite Screen (earth conductor): Tinned annealed copper braiding interwove with polyester yarn
  • Cradle Separator: Semiconductive PCP
  • 1×Central Extensible Pilot: EPR covered flexible stranded tinned copper conductor
  • Sheath: Heavy-duty PCP sheath. Heavy duty CPE/CSP sheath can be offered upon request
 

 

 

 

Application

 

 

Mining cable is typically designed as a trailing cable, intended to follow the movement of mining equipment, providing power as machinery is repositioned at a mining site. Unlike reeled cables, which are designed to be repeatedly wound and unwound, trailing cables are more flexible and rugged, suitable for use in environments where equipment is frequently moved, towed or relocated. The cable can withstand frequent bending, twisting and pulling, which is common in mining operations where machinery needs to be relocated over rough terrain. The flexibility of mining cable ensures that it can easily move with the equipment, preventing damage and reducing the need for frequent repairs or replacements.

mining cable application

 

Feature

 

SAA mining cable

 

Mining cables feature flexible stranded tinned annealed copper conductors that ensure efficient power transmission while remaining flexible for easy handling and installation in mobile applications. The conductors are designed to withstand mechanical stress and environmental factors such as abrasion and shock, making them ideal for use in mining operations where the cables are constantly moving and operating in harsh conditions. The conductor shield is made of a semi-conducting compound, which helps prevent electrical interference and ensures safe and efficient operation of the power system. The insulation is made of EPR (ethylene propylene rubber) which offers excellent resistance to heat, moisture and electrical stress.

 

Certification

 

Mining cable has passed SAA (Australia and New Zealand Certification Agency) certification and complies with safety standards and regulations in Australia and New Zealand. This certification ensures the reliability and safety of mining cables in extreme environments, especially in dangerous conditions such as high temperature, humidity, and fire. SAA-certified mining cables can effectively resist external mechanical shock, chemical corrosion, and electrical failures to ensure the stable operation of the power system. The certification process includes rigorous testing to ensure that the cable can maintain good conductivity and durability under heavy loads, high temperatures, and harsh conditions, greatly improving the safety of power transmission in mining operations.

 

 

TPS cable SAA certification

 

Package

 

fire alarm cable GREATER GERITEL WIRE

 

Company Introduction

 

SAA cable factory

 

Greater Wire manufacturer's advanced cable factory has an intelligent and digital manufacturing environment. Through the seamless integration of cutting-edge technology, the factory successfully eliminates errors and defects that may occur in the traditional manual assembly process. The shift to digital manufacturing not only increases efficiency but also demonstrates our commitment to providing our customers with products of the highest reliability. The smart factory framework ensures a streamlined and error-free production process, minimizing the possibility of human-related variances and increasing previously unattainable precision. Accurate and automated inspection mechanism, the factory strictly adheres to quality control. Products are thoroughly inspected from the beginning to the final stage of the manufacturing process. Digital intelligent image detection and laser technologies are used to ensure that each product meets the strict standards set by our company. This commitment to quality extends to our inspection accuracy, with automated production equipment achieving an impressive accuracy of 0.002 mm, exceeding industry benchmarks.

 

customer

 

cable GREATER GERITEL WIRE

 

 

Partner

 

greater wire Partner

 

FAQ

 

 

 

 

Q: What is a mining cable?

A:  In the context of traditional industrial mining (such as coal, gold, or other mineral extraction), mining cables refer to the heavy-duty cables used to provide power to mining equipment, lighting, and communication systems in underground mines or other harsh environments.

Q: What is mineral cable used for?

A: A mineral-insulated (MI) cable is a high-performance cable designed to withstand extreme temperatures and harsh conditions. Its unique construction makes it highly resistant to fire and oxidation, ensuring reliable operation even in environments with elevated heat. With its robust insulation and durable materials, MI cables are ideal for applications requiring precise measurements, offering long-term stability and safety in demanding industrial, electrical, and hazardous settings.

Q: Why do they call it mining cable?

A:  Underground Mining: The term "mining" comes from the traditional mining industry, where cables are used to provide power to machinery, ventilation systems, lighting, and communication networks in underground mines. Mining cables are specifically designed to endure harsh environments, such as extreme temperatures, moisture, physical wear, and the risk of fire or explosion.
Durability and Safety:
Mining cables need to be robust and able to resist mechanical stress, chemical exposure, and high temperatures, making them essential in the mining industry.

 

 

Hot Tags: type 209 1.1 to 11kv mining cable, China type 209 1.1 to 11kv mining cable manufacturers, suppliers, factory, SAA Australia Flat 2C E Electrical TPS Cable, High Temp Ultra Flexible Silicone Insulated Wire, 2 3 4 5 Core Kabel H05VV F, Kabel H05RR F, solar cable, ul1007 hook up wire

mining cable specification

 

 

 

Nominal
Conductor
Area

Strand Size

Insulation
Thickness

Core Screen
Pilot Conductor
Thickness
of Sheath
Nominal
Overall
Diameter
Nominal
Weight
Strand Size
Area of
Screen
Strand Size
Thickness
of Covering
mm²
No/mm
mm
No/mm
mm²
No/mm
mm
mm
mm
kg/100m
Type 209.1
6 84/0.30 1.5 7/0.25 7.2 24/0.20 0.8 3.8 30.0 129
10 77/0.40 1.5 7/0.25 8.6 24/0.20 0.8 3.8 32.6 157
16 126/0.40 1.6 7/0.25 9.6 24/0.20 0.8 4.0 35.8 197
25 209/0.40 1.6 7/0.25 11.3 24/0.20 0.8 4.3 39.7 255
35 285/0.40 1.6 7/0.25 12.4 24/0.20 0.8 4.6 43.1 312
50 380/0.40 1.7 7/0.25 14.1 40/0.20 0.8 5.0 47.7 386
70 203/0.67 1.8 7/0.25 16.5 40/0.20 0.8 5.4 52.8 503
95 259/0.67 2.0 7/0.25 18.2 40/0.20 0.8 6.0 58.6 605
120 336/0.67 2.1 7/0.25 20.3 40/0.20 0.8 6.4 64.4 741
150 427/0.67 2.3 7/0.25 22.3 40/0.20 0.8 6.9 70.2 896
185 518/0.67 2.5 7/0.30 30.2 40/0.20 0.8 7.4 77.4 1092
240 672/0.67

2.8

7/0.30 33.6 40/0.20 0.8 8.2 86.0 1365
300 854/0.67 3.0 7/0.40 50.1 40/0.20 0.8 8.8 95.1 1715
Type 209.3
16 126/0.40 3.0 7/0.25 13.1 24/0.20 0.8 5.3 46.2 301
25 209/0.40 3.0 7/0.25 14.8 24/0.20 0.8 5.6 50.1 369
35 285/0.40 3.0 7/0.25 15.8 24/0.20 0.8 5.9 53.5 431
50 380/0.40 3.0 7/0.25 17.2 40/0.20 0.8 6.3 57.6 507
70 203/0.67 3.0 7/0.25 18.6 40/0.20 0.8 6.6 62.5 624
95 259/0.67 3.0 7/0.25 20.3 40/0.20 0.8 7.1 66.2 719
120 336/0.67 3.0 7/0.30 27.2 40/0.20 0.8 7.4 72.0 876
150 427/0.67 3.0 7/0.40 39.6 40/0.20 0.8 7.8 78.0 1072
185 518/0.67 3.0 7/0.40 42.2 40/0.20 0.8 8.2 83.4 1236
240 672/0.67 3.0 7/0.40 46.6 40/0.20 0.8 8.8 90.3 1500
300 854/0.67 3.0 7/0.50 63.2 40/0.20 0.8 9.4 98.4 1840
Type 209.6
16 126/0.40 5.0 7/0.25 17.2 24/0.20 0.8 6.4 57.3 435
25 209/0.40 5.0 7/0.25 18.6 24/0.20 0.8 6.7 61.2 512
35 285/0.40 5.0 7/0.25 18.6 40/0.20 0.8 7.0 64.6 582
50 380/0.40 5.0 7/0.25 21.3 40/0.20 0.8 7.3 68.5 668
70 203/0.67 5.0 7/0.25 23.4 40/0.20 0.8 7.7 73.7 799
95 259/0.67 5.0 7/0.30 29.4 40/0.20 0.8 8.1 77.8 935
120 336/0.67 5.0 7/0.30 31.7 40/0.20 0.8 8.5 83.1 1090
150 427/0.67 5.0 7/0.40 45.7 40/0.20 0.8 8.9 89.1 1310
185 518/0.67 5.0 7/0.40 48.4 40/0.20 0.8 9.3 94.5 1480
240 672/0.67 5.0 7/0.40 52.8 40/0.20 0.8 9.9 101.4 1750
300 854/0.67 5.0 7/0.50 71.5 40/0.20 0.8 10.4 109.3 2120
Type 209.11
25 209/0.40 7.6 7/0.25 23.7 24/0.20 0.8 8.1 75.6 750
35 285/0.40 7.6 7/0.39 30.2 24/0.20 0.8 8.4 79.7 858
50 380/0.40 7.6 7/0.30 31.7 40/0.20 0.8 8.7 83.6 960
70 203/0.67 7.6 7/0.30 34.1 40/0.20 0.8 9.1 88.8 1093
95 259/0.67 7.6 7/0.40 47.5 40/0.20 0.8 9.6 93.7 1267
120 336/0.67 7.6 7/0.40 51.0 40/0.20 0.8 9.9 98.8 1436
150 427/0.67 7.6 7/0.40 53.7 40/0.20 0.8 10.3 103.5 1614
185 518/0.67 7.6 7/0.40 57.2 40/0.20 0.8 10.7 108.8 1830

 

Send Inquiry