Non-Migratory Flat Cable 450/750V For Fixed Building Wiring

Non-Migratory Flat Cable 450/750V For Fixed Building Wiring
Details:
·Insulation: V-90 PVC
·Colour: Red, Black, Green/Yellow
·Sheath: 3V-90 PVC
·Colour: Purple
·Approvals: AS/NZS 5000.2
·Normal operating temperature: +90℃
·Minimum operating temperature: 0℃
Send Inquiry
Download
Description
Technical Parameters
Certification

V-90 insulated building cable

PRODUCT REAL SHOT

 

V-90 insulated flat cable
V-90 insulated purple TPS cable
V-90 insulated non-migratory cable

V-90 insulated fixed wiring cable

Purple Building Cable Designed for Stable PVC Contact Performance
GERITEL WIRE supplies this product for fixed power and lighting circuits in residential, prefabricated and light-commercial buildings. It uses plain annealed copper conductors, V-90 PVC insulation and a purple non-migratory PVC sheath and is intended for where conventional PVC cable may be exposed to polymer-based building materials or thermal insulation. The page targets flat TPS non migratory, 450/750V non-migratory cable and PVC insulated PVC sheathed non-migratory cable to match real searches across product, application and procurement intent. Buyers can confirm conductor size, cable marking, packing and compliance files before order; mixed-size and project supply are available.
PRODUCT SPECIFICATIONS

 

3V-90 sheathed TPS cable

 

Application

 

Suitable for light to medium industrial use and all building internal wiring applications. Insulation & sheathing material is non-migratory and best to be used in cable that are in contact with polystyrene, acrylic, ABS and polycarbonate.This cable is suitable for installation of wall or roofing mate-rial, caravans, cold rooms, and transportable buildings. 

SPECIFICATIONS
Approvals AS/NZS5000.2

Behaviour in flame

and fire

Flame retardant
Temperature range

Normal operating temperature: +90°C

Minimum operating temperature: 0°C

Flexibility Semi-rigid
Minimum bending radius

6x0D during install

4x0D once installed

Resistance to

Chemical exposure: Occasional

Mechanical impact: Light

Water exposure: Occasional condensation

Solar radiation and

weather exposure: Occasional

Cable design

Conductor:

Plain annealed copper conductor to AS/NZS 1125 Can also be operated at temperatures up to 90°C when not exposed to mechanical deformation (see AS/NZS 3008.1).

Insulation: V-90 PVC
Colours: Red, Black,Green/Yellow

Sheath: 3V-90PVC

Colour: Purple

Installation conditions

In free air

In conduit

In trench

In duct

External building with protection

Insulation Colours

Conductor

Cable

Min.

installed

bending

radius(a)

mm

Nominal

C.S.A

mm²

Nominal

diameter

of wires
No/mm

Nominal

diameter

mm

Nominal

insulation

thickness

mm

Overall diameter mm

Approx.

mass

kg/100m

Minimum

Maximum

Major axis Major axis Major axis Major axis
TWIN FLAT PVC
Red,Green/Yellow,Black 1.0 7/0.42 1.26 0.6 9.5 4.3 9.6 4.4 8 20
Red,Green/Yellow,Black 1.5 7/0.50 1.56 0.6 9.8 4.5 10.1 4.6 10 20
Red,Green/Yellow,Black 2.5 7/0.67 2.0 0.7 12.1 5.4 12.4 5.5 15 20
Red,Green/Yellow,Black 4 7/0.85 2.6 0.8 13.8 6.3 14.1 6.5 19 30
Red,Green/Yellow,Black 6 7/1.04 3.1 0.8 14.9 6.9 15.3 7.1 24 30
Red,Green/Yellow,Black 10 7/1.35 4.1 1 18.9 8.4 19.6 8.8 38 35
Red,Green/Yellow,Black 16 7/1.70 5.1 1 21.8 9.7 22.5 10.0 54 40
CERTIFICATIONS

 

3V-90 sheathed building cable

 

 

PACKAGING

 

3V-90 sheathed flat cable

Roll

3V-90 sheathed purple TPS cable

Small Wooden Reel

3V-90 sheathed non-migratory cable

Plastic Reel

APPLICATION

 

3V-90 sheathed fixed wiring cable
Capsule Accommodation
plain annealed copper building cable
Prefabricated Housing
plain annealed copper flat cable

Recreational Vehicle Wiring

 

CASE

 

plain annealed copper purple TPS cable

2020 Ford Transit AWD Camper Van Conversion

plain annealed copper fixed wiring cable

Epping Forest District Council Modular Homes

Class 2 copper conductor TPS cable

Wethersfield Modular Accommodation Deployment

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

Class 2 copper conductor building cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

Class 2 copper conductor flat cable
 
Class 2 copper conductor purple TPS cable
 
Class 2 copper conductor non-migratory cable
 
Class 2 copper conductor fixed wiring cable
 
AS/NZS 1125 copper conductor TPS cable
 
AS/NZS 1125 copper conductor building cable
 
GLOBAL CERTIFICATIONS

 

AS/NZS 1125 copper conductor purple TPS cable

CUSTOMER PHOTOS
 

AS/NZS 1125 copper conductor non-migratory cable

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

AS/NZS 1125 copper conductor fixed wiring cable
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

AS/NZS 3808 PVC TPS cable
AS/NZS 3808 PVC building cable
AS/NZS 3808 PVC flat cable
AS/NZS 3808 PVC purple TPS cable
AS/NZS 3808 PVC non-migratory cable
AS/NZS 3808 PVC fixed wiring cable
450/750V fixed wiring TPS cable
450/750V fixed wiring building cable
450/750V fixed wiring flat cable
450/750V fixed wiring purple TPS cable
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

450/750V fixed wiring non-migratory cable
FAQ

 

Why does polystyrene appear to melt around PVC cable?
The apparent melting effect is associated with plasticiser moving from the PVC into the polystyrene, while the PVC itself becomes less plasticised. When comparing suppliers, do not judge PVC cable plasticiser migration only by price or purple colour. Ask for the ordered-size datasheet, cable marking, applicable certificate references and packing details. GERITEL WIRE can review the project material and application information before recommending the ordered construction. This gives contractors and distributors a clearer basis for technical approval and repeat purchasing.
How quickly does cable damage happen in polystyrene?
Migration rate varies with temperature, material thickness and the area of direct contact, so deterioration time cannot be predicted from colour or size alone. For this type of project, plasticiser migration resistant cable should be selected from a documented construction rather than by sheath colour alone. GERITEL WIRE can arrange samples for structure and material confirmation before bulk purchasing. Final installation and circuit design should follow the applicable local wiring rules and be checked by a licensed electrical professional.
Can non-migratory TPS be embedded in polystyrene roof insulation?
Roof and wall insulation are recognized applications for non-migratory cable, but thermal derating and mechanical protection still need separate design checks. In practice, non-migratory cable for polystyrene roof panels is most useful when the buyer can verify conductor, insulation, sheath and application compatibility before ordering. GERITEL WIRE can keep size, marking and packaging specifications consistent across repeat project orders. If the surrounding material, temperature or installation method is unusual, send the project details for confirmation instead of assuming suitability.
Does using non-migratory cable remove the need for derating in insulation?
No. Non-migratory performance addresses material compatibility; current-carrying capacity can still be affected when a cable is surrounded by thermal insulation. The key point is that non-migratory cable installation in thermal insulation is a fixed-wiring product with a defined 450/750V construction, not a universal cable for every environment. GERITEL WIRE can provide the construction drawing and ordered-size datasheet before approval. The installer still needs to check route, mechanical protection, thermal conditions and local code requirements.

 

Hot Tags: non-migratory flat cable 450/750v for fixed building wiring, China non-migratory flat cable 450/750v for fixed building wiring manufacturers, suppliers, factory

Send Inquiry