AC90 3 Conductor Cable For Panel Homeruns And Distribution Wiring

AC90 3 Conductor Cable For Panel Homeruns And Distribution Wiring
Details:
·Conductor: Solid Soft Copper, ASTM B3 8-2 AWG - Stranded Soft Copper, ASTM B8
·Insulation: Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
·Colour Code: Black, White and Red / Black, White and Green
·Bonding Conductor: Solid ASTM B3 or Stranded ASTM B8 Soft Bare Copper
·Armour: Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
·Voltage Rating: 600V
Send Inquiry
Download
Description
Technical Parameters
Certification

Dongguan Greater Wire & Cable Co., Ltd. is one of the leading manufacturers and suppliers of ac90 3 conductor cable for panel homeruns and distribution wiring in China, also supports customized service. Please rest assured to wholesale durable ac90 3 conductor cable for panel homeruns and distribution wiring made in China here from our factory. If you have any enquiry about free sample, please feel free to email us.

 

AC90 wire for manufactured wiring systems

PRODUCT REAL SHOT

 

AC90 cable for prefabricated wiring systems
AC90 wire for prefabricated wiring systems
AC90 cable for modular office wiring

AC90 wire for modular office wiring

Copper armoured wire for runs from panelboards to branch and distribution loads
AC90 panel homerun cable is designed for panel homeruns, distribution boards and electrical-room building circuits. The cable combines three insulated copper circuit conductors with RW90 XLPE insulation, a bare copper bonding conductor, paper wrap and flexible interlocked aluminium armour in a 600V building-wire construction. The armour provides useful mechanical protection while maintaining practical routing flexibility through walls, ceilings and service spaces. GERITEL WIRE supplies AC90 power distribution cable for professional B2B buyers with custom marking, reel or coil packaging, batch documentation and scheduled production support. The product is intended for suitable dry indoor installations where AC90/BX is permitted, with final circuit sizing and installation following the applicable code and project design.
PRODUCT SPECIFICATIONS

 

AC90 cable for modular school wiring

APPLICATIONS

 

Manufactured, tested and certified in Canada, GERITEL WIRE AC90 armoured building wire is rated FT4-ST1 for -40°C to 90°C. Engineered specifically for demanding environments, superior flammability and smoke emission performance.

For use in ventilated, non-ventilated and ladder-type cable trays.

For dry locations, in ceiling air-handling plenums, exposed or concealed wiring and service entrance above ground.

SPECIFICATIONS
Conductor Solid Soft Copper, ASTM B3 8-2 AWG - Stranded Soft Copper, ASTM B8
Insulation Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
Colour Code Black, White and Red / Black, White and Green
Bonding Conductor Solid ASTM B3 or Stranded ASTM B8 Soft Bare Copper
Armour Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
Specifications and Compliance

CSA C22.2 No. 51, Armoured Cables (Type AC90)

CSA C22.2 No. 38 Thermoset-insulated wires and cables (Type RW90)

CSA C22.2 No. 2556 FT4-ST1/UL 1685 Vertical-Tray Flame Test

IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test rated

-40°C Cold Bend and -40°C Cold Impact

Limited Smoke and Halogen Free

AC90 & ISO-AC90 600V CSA FT4-ST1 LSZH

 

AC90

Power

Conductor

Ground

Conductor

Insulation

Thickness

Armour

O.D

Cable

Weight

Max Pulling

Tension

Min Bend Radius Ampacity
Count AWG AWG in mm in mm lbs/Mft kg/km lbs kg in mm A
2 14 14 0.030 0.76 0.430 10.9 81 120 66 30 6.0 151 25
2 12 14 0.030 0.76 0.454 11.5 99 148 104 47 6.4 164 30
2 10 12 0.030 0.76 0.512 13.0 138 206 166 75 6.9 174 40
3 14 14 0.030 0.76 0.445 11.3 105 156 99 45 6.2 158 25
3 12 14 0.030 0.76 0.490 12.4 130 193 157 71 6.9 174 30
3 10 12 0.030 0.76 0.535 13.6 182 271 249 113 7.5 190 40
3 8/7 10 0.045 1.14 0.714 18.1 309 460 418 190 10.0 254 55
3 6/7 8/7 0.045 1.14 0.770 19.6 417 621 702 318 10.8 274 75
3 4/7 8/7 0.045 1.14 0.940 23.9 601 894 1193 541 13.2 334 95
3 3/7 6/7 0.045 1.14 0.990 25.1 721 1073 1622 736 13.9 352 115
3 2/7 6/7 0.045 1.14 1.040 26.4 891 1326 1922 872 14.6 370 130
4 14 14 0.030 0.76 0.490 12.4 130 193 131 60 6.9 174 20
4 12 14 0.030 0.76 0.535 13.6 166 247 209 95 7.5 190 24
4 10 12 0.030 0.76 0.630 16.0 232 345 332 150 8.8 224 32

 

ISO-AC90

Conductor

Count

Power

Conductor

Ins.Ground

Conductor

Ground

Conductor

Insulation

Thickness

Armour

O.D

Cable

Weight

Max Pulling

Tension

Min Bend Radius Ampacity
AWG AWG AWG in mm in mm lbs/Mft kg/km lbs kg in mm A
2 14 14 14 0.030 0.76 0.440 11.2 105 156 66 30 6.2 157 25
2 12 12 14 0.030 0.76 0.485 12.3 138 206 104 47 6.8 173 30
2 10 10 12 0.030 0.76 0.533 13.5 186 277 166 75 7.5 190 40
3 12 12 14 0.030 0.76 0.535 13.6 165 245 157 71 7.5 190 24
3 10 10 12 0.030 0.76 0.591 15.0 232 346 249 113 8.3 210 32
CERTIFICATIONS

 

AC90 wire for modular school wiring

PACKAGING

 

AC90 cable for modular healthcare building wiring

Roll

AC90 residential cable

Plastic Reel

AC90 residential wire

Small Wooden Reel

APPLICATION

 

AC90 apartment cable
Apartment/Residential Building Electrical Distribution
AC90 wire for modular healthcare building wiring
Commercial Building Electrical Distribution
AC90 cable for tiny house wiring
Industrial Factory Power Distribution
CASE

 

AC90 wire for tiny house wiring

Calgary Alberta Multi Storey Apartment Construction Upgrade

AC90 cable for wood cabin wiring

Toronto Ontario Detached House Basement Panel Upgrade

AC90 feeder wire

Vancouver British Columbia Downtown Office Renovation

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

AC90 wire for wood cabin wiring
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

AC90 wire for container house wiring
 
AC90 cable for container house wiring
 
AC90 wire for container house wiring
 
AC90 cable Canada
 
AC90 wire Canada
 
AC90 wire for off site construction wiring
 
GLOBAL CERTIFICATIONS

 

AC90 cable for factory built housing wiring

CUSTOMER PHOTOS
 

AC90 wire for factory built housing wiring

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

AC90 cable for integrated housing electrical wiring
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

AC90 wire for integrated housing electrical wiring
AC90 cable for data center building wiring
AC90 cable for data centre building wiring
AC90 wire for data centre building wiring
BX AC90 cable
BX AC90 wire
BX armoured cable AC90
AC90 cable for data center branch circuit wiring
AC90 wire for data center branch circuit wiring
AC90 cable for server room general power wiring
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

AC90 wire for server room general power wiring
FAQ

 

Can AC90 be used around EV charging infrastructure?
AC90 cable for EV facility wiring can support suitable dry indoor building circuits around EV charging facilities, such as lighting and electrical-room power. It is not the vehicle charging lead.
Can AC90 be used in green building projects?
Yes. AC90 cable for green buildings can be specified in green-building projects where the project accepts AC90 and the exact cable meets required performance and documentation criteria.
Can AC90 be installed outdoors?
Standard AC90 dry location cable should not be selected as a general outdoor cable. For wet or weather-exposed installations, choose a cable specifically certified for those conditions.
Can AC90 be used in wet locations?
Standard AC90 dry location wire is primarily intended for dry-location building wiring. Wet-rated insulation on individual conductors does not automatically make the complete AC90 cable suitable for wet locations.
 

 

Hot Tags: ac90 3 conductor cable for panel homeruns and distribution wiring, China ac90 3 conductor cable for panel homeruns and distribution wiring manufacturers, suppliers, factory, ac cable, AC Power Cable

Send Inquiry