·Conductor: Solid Soft Copper, ASTM B3
·Insulation: Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
·Colour Code: Black, Red
·Bonding Conductor: Solid ASTM B3 Soft Bare Copper
·Armour: Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
·Voltage Rating: 600V
Send Inquiry
Download
Description
Technical Parameters
Certification

Dongguan Greater Wire & Cable Co., Ltd. is one of the leading manufacturers and suppliers of ac90 armoured cable 2c black red for above ceiling wiring 600v in China, also supports customized service. Please rest assured to wholesale durable ac90 armoured cable 2c black red for above ceiling wiring 600v made in China here from our factory. If you have any enquiry about free sample, please feel free to email us.

 

FT4 AC90 wire

PRODUCT REAL SHOT

 

zero halogen AC90 cable
zero halogen AC90 wire
limited smoke AC90 cable

limited smoke AC90 wire

Flexible copper building wire for commercial ceiling and service spaces
For above ceiling wiring, AC90 above ceiling wiring offers a practical alternative to separate raceway and individual conductor installation in locations where AC90 is permitted. Copper conductors provide dependable electrical performance, RW90 XLPE supplies insulation, and the interlocked aluminum armour protects the cable core while keeping the assembly flexible. The Black/Red two-conductor format is easy to identify during installation. Buyers sourcing AC90 armoured cable from GERITEL WIRE can request project quantities, custom printing, private-label packaging and repeat manufacturing schedules. The 600V cable is positioned for dry-location building wiring and should be selected according to the exact circuit design, certification and local installation rules.
PRODUCT SPECIFICATIONS

 

dry location AC90 cable

APPLICATIONS

 

Manufactured, tested and certified in Canada, GERITEL WIRE AC90 armoured building wire is rated FT4-ST1 for -40°C to 90°C. Engineered specifically for demanding environments, superior flammability and smoke emission performance.

Designed for Single-Phase Heating Installations.

For use in ventilated, non-ventilated and ladder-type cable trays.

For dry locations, in ceiling air-handling plenums, exposed or concealed wiring and service entrance above ground.

SPECIFICATIONS
Conductor Solid Soft Copper, ASTM B3
Insulation Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
Colour Code Black, Red
Bonding Conductor Solid ASTM B3 Soft Bare Copper
Armour Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
Specifications and Compliance

CSA C22.2 No. 51, Armoured Cables (Type AC90)

CSA C22.2 No. 38 Thermoset-insulated wires and cables (Type RW90)

CSA C22.2 No. 2556 FT4-ST1/UL 1685 Vertical-Tray Flame Test

IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test rated

-40°C Cold Bend and -40°C Cold Impact

Limited Smoke and Halogen Free

AC90 & ISO-AC90 600V CSA FT4-ST1 LSZH

 

AC90

Power

Conductor

Ground

Conductor

Insulation

Thickness

Armour

O.D

Cable

Weight

Max Pulling

Tension

Min Bend Radius Ampacity
Count AWG AWG in mm in mm lbs/Mft kg/km lbs kg in mm A
2 14 14 0.030 0.76 0.430 10.9 81 120 66 30 6.0 151 25
2 12 14 0.030 0.76 0.454 11.5 99 148 104 47 6.4 164 30
2 10 12 0.030 0.76 0.512 13.0 138 206 166 75 6.9 174 40
3 14 14 0.030 0.76 0.445 11.3 105 156 99 45 6.2 158 25
3 12 14 0.030 0.76 0.490 12.4 130 193 157 71 6.9 174 30
3 10 12 0.030 0.76 0.535 13.6 182 271 249 113 7.5 190 40
3 8/7 10 0.045 1.14 0.714 18.1 309 460 418 190 10.0 254 55
3 6/7 8/7 0.045 1.14 0.770 19.6 417 621 702 318 10.8 274 75
3 4/7 8/7 0.045 1.14 0.940 23.9 601 894 1193 541 13.2 334 95
3 3/7 6/7 0.045 1.14 0.990 25.1 721 1073 1622 736 13.9 352 115
3 2/7 6/7 0.045 1.14 1.040 26.4 891 1326 1922 872 14.6 370 130
4 14 14 0.030 0.76 0.490 12.4 130 193 131 60 6.9 174 20
4 12 14 0.030 0.76 0.535 13.6 166 247 209 95 7.5 190 24
4 10 12 0.030 0.76 0.630 16.0 232 345 332 150 8.8 224 32

 

ISO-AC90

Conductor

Count

Power

Conductor

Ins.Ground

Conductor

Ground

Conductor

Insulation

Thickness

Armour

O.D

Cable

Weight

Max Pulling

Tension

Min Bend Radius Ampacity
AWG AWG AWG in mm in mm lbs/Mft kg/km lbs kg in mm A
2 14 14 14 0.030 0.76 0.440 11.2 105 156 66 30 6.2 157 25
2 12 12 14 0.030 0.76 0.485 12.3 138 206 104 47 6.8 173 30
2 10 10 12 0.030 0.76 0.533 13.5 186 277 166 75 7.5 190 40
3 12 12 14 0.030 0.76 0.535 13.6 165 245 157 71 7.5 190 24
3 10 10 12 0.030 0.76 0.591 15.0 232 346 249 113 8.3 210 32
CERTIFICATIONS

 

dry location AC90 wire

PACKAGING

 

indoor AC90 cable

Roll

indoor AC90 wire

Plastic Reel

open wiring AC90 cable

Small Wooden Reel

APPLICATION

 

open wiring AC90 wire
Apartment/Residential Building Electrical Distribution
concealed wiring AC90 cable
Commercial Building Electrical Distribution
concealed wiring AC90 wire
Industrial Factory Power Distribution
CASE

 

AC90 cable for prefab house wiring

Calgary Alberta Multi Storey Apartment Construction Upgrade

ceiling fixture AC90 cable

Toronto Ontario Detached House Basement Panel Upgrade

ceiling fixture AC90 wire

Vancouver British Columbia Downtown Office Renovation

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

cable trough AC90 cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

ventilated cableway AC90 cable
 
cable trough AC90 wire
 
AC90 cable for manufactured home interior wiring
 
AC90 wire for manufactured home interior wiring
 
ventilated cableway AC90 wire
 
AC90 electrical cable CSA certified
 
GLOBAL CERTIFICATIONS

 

commercial grade AC90 cable

CUSTOMER PHOTOS
 

commercial grade AC90 wire

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

contractor grade AC90 cable
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

contractor grade AC90 wire
Canadian building wire AC90 cable
Canadian building wire AC90 wire
AC90 cable for container house interior wiring
AC90 electrical cable cUL CSA certified
AC90 2 conductor cable cUL CSA certified
AC90 wire for container house interior wiring
protected branch circuit AC90 cable
protected branch circuit AC90 wire
AC90 copper cable 600V
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

CSA C22.2 No. 51 AC90 cable
FAQ

 

Is UL1569 the AC90 standard?
For AC90 certification, Canadian armoured-cable requirements are the relevant basis for the AC90 model. UL 1569 is associated with MC cable in the US scope, so certification wording should match the actual model and authorization.
Is FT4 available on AC90?
ST1 AC90 cable may be available in specific certified constructions. Low-smoke claims must be verified on the exact product rather than assumed for every AC90 cable.
Is ST1 available on AC90?
ST1 AC90 cable may be available in specific certified constructions. Low-smoke claims must be verified on the exact product rather than assumed for every AC90 cable.
Is AC90 RoHS compliant?
RoHS compliant AC90 cable can be supplied where the certified material system and customer specification support the requirement. Relevant compliance documentation can be reviewed for B2B projects.
 

 

Hot Tags: ac90 armoured cable 2c black red for above ceiling wiring 600v, China ac90 armoured cable 2c black red for above ceiling wiring 600v manufacturers, suppliers, factory

Send Inquiry