Details:
·Conductor: Solid Soft Copper, ASTM B3
·Insulation: Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
·Colour Code: Black, Red
·Bonding Conductor: Solid ASTM B3 Soft Bare Copper
·Armour: Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
·Voltage Rating: 600V
Send Inquiry
Download
Description
Technical Parameters
Certification

Dongguan Greater Wire & Cable Co., Ltd. is one of the leading manufacturers and suppliers of ac90 copper wire black red 2c 600v for steel stud wall wiring in China, also supports customized service. Please rest assured to wholesale durable ac90 copper wire black red 2c 600v for steel stud wall wiring made in China here from our factory. If you have any enquiry about free sample, please feel free to email us.

 

no outer jacket AC90 cable

PRODUCT REAL SHOT

 

no outer jacket AC90 wire
mechanically protected AC90 cable
mechanically protected AC90 wire

mechanical protection AC90 cable

Armoured branch-circuit cable for modern commercial interior framing
AC90 cable for steel stud walls is engineered for steel stud wall wiring, combining copper circuit conductors, RW90 XLPE insulation, a bare copper bonding conductor, paper wrap and flexible interlocked aluminum armour in one 600V assembly. The 2 Conductor Black/Red configuration provides clear circuit identification and is intended for suitable dry indoor building circuits where AC90 is accepted by the project design and local code. GERITEL WIRE supplies AC90 copper wire to contractors, distributors and project buyers with custom cable marking, reel or coil packaging, documentation support and scheduled production. The integrated armour gives practical mechanical protection while retaining the flexibility needed for walls, ceilings, service spaces and repeat project installations.
PRODUCT SPECIFICATIONS

 

mechanical protection AC90 wire

APPLICATIONS

 

Manufactured, tested and certified in Canada, GERITEL WIRE AC90 armoured building wire is rated FT4-ST1 for -40°C to 90°C. Engineered specifically for demanding environments, superior flammability and smoke emission performance.

Designed for Single-Phase Heating Installations.

For use in ventilated, non-ventilated and ladder-type cable trays.

For dry locations, in ceiling air-handling plenums, exposed or concealed wiring and service entrance above ground.

SPECIFICATIONS
Conductor Solid Soft Copper, ASTM B3
Insulation Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
Colour Code Black, Red
Bonding Conductor Solid ASTM B3 Soft Bare Copper
Armour Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
Specifications and Compliance

CSA C22.2 No. 51, Armoured Cables (Type AC90)

CSA C22.2 No. 38 Thermoset-insulated wires and cables (Type RW90)

CSA C22.2 No. 2556 FT4-ST1/UL 1685 Vertical-Tray Flame Test

IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test rated

-40°C Cold Bend and -40°C Cold Impact

Limited Smoke and Halogen Free

AC90 & ISO-AC90 600V CSA FT4-ST1 LSZH

 

AC90

Power

Conductor

Ground

Conductor

Insulation

Thickness

Armour

O.D

Cable

Weight

Max Pulling

Tension

Min Bend Radius Ampacity
Count AWG AWG in mm in mm lbs/Mft kg/km lbs kg in mm A
2 14 14 0.030 0.76 0.430 10.9 81 120 66 30 6.0 151 25
2 12 14 0.030 0.76 0.454 11.5 99 148 104 47 6.4 164 30
2 10 12 0.030 0.76 0.512 13.0 138 206 166 75 6.9 174 40
3 14 14 0.030 0.76 0.445 11.3 105 156 99 45 6.2 158 25
3 12 14 0.030 0.76 0.490 12.4 130 193 157 71 6.9 174 30
3 10 12 0.030 0.76 0.535 13.6 182 271 249 113 7.5 190 40
3 8/7 10 0.045 1.14 0.714 18.1 309 460 418 190 10.0 254 55
3 6/7 8/7 0.045 1.14 0.770 19.6 417 621 702 318 10.8 274 75
3 4/7 8/7 0.045 1.14 0.940 23.9 601 894 1193 541 13.2 334 95
3 3/7 6/7 0.045 1.14 0.990 25.1 721 1073 1622 736 13.9 352 115
3 2/7 6/7 0.045 1.14 1.040 26.4 891 1326 1922 872 14.6 370 130
4 14 14 0.030 0.76 0.490 12.4 130 193 131 60 6.9 174 20
4 12 14 0.030 0.76 0.535 13.6 166 247 209 95 7.5 190 24
4 10 12 0.030 0.76 0.630 16.0 232 345 332 150 8.8 224 32

 

ISO-AC90

Conductor

Count

Power

Conductor

Ins.Ground

Conductor

Ground

Conductor

Insulation

Thickness

Armour

O.D

Cable

Weight

Max Pulling

Tension

Min Bend Radius Ampacity
AWG AWG AWG in mm in mm lbs/Mft kg/km lbs kg in mm A
2 14 14 14 0.030 0.76 0.440 11.2 105 156 66 30 6.2 157 25
2 12 12 14 0.030 0.76 0.485 12.3 138 206 104 47 6.8 173 30
2 10 10 12 0.030 0.76 0.533 13.5 186 277 166 75 7.5 190 40
3 12 12 14 0.030 0.76 0.535 13.6 165 245 157 71 7.5 190 24
3 10 10 12 0.030 0.76 0.591 15.0 232 346 249 113 8.3 210 32
CERTIFICATIONS

 

flexible armoured AC90 cable

PACKAGING

 

flexible armoured AC90 wire

Roll

flexible armored AC90 cable

Plastic Reel

flexible armored AC90 wire

Small Wooden Reel

APPLICATION

 

90 degree AC90 cable
Apartment/Residential Building Electrical Distribution
90 degree AC90 cable
Commercial Building Electrical Distribution
90 degree AC90 wire
Industrial Factory Power Distribution
CASE

 

90C AC90 cable

Calgary Alberta Multi Storey Apartment Construction Upgrade

90C AC90 wire

Toronto Ontario Detached House Basement Panel Upgrade

minus 40 installation AC90 cable

Vancouver British Columbia Downtown Office Renovation

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

minus 40 installation AC90 wire
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

low temperature AC90 cable
 
low temperature AC90 wire
 
600V copper AC90 cable
 
600V copper AC90 wire
 
600 volt copper AC90 cable
 
600 volt copper AC90 wire
 
GLOBAL CERTIFICATIONS

 

lead free AC90 cable

CUSTOMER PHOTOS
 

lead free AC90 wire

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

RoHS compliant AC90 cable
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

RoHS compliant AC90 wire
low smoke AC90 wire
low smoke AC90 cable
AC90 cable for maintenance room wiring
AC90 wire for maintenance room wiring
AC90 cable for indoor production support wiring
AC90 wire for indoor production support wiring
ST1 AC90 cable
ST1 AC90 wire
AC90 cable for prefabricated building wiring
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

FT4 AC90 cable
FAQ

 

Can multiple AC90 cables be bundled together?
Multiple AC90 branch circuit cable runs may be grouped only when code requirements for ampacity adjustment, heat dissipation, support and bundling are satisfied.
What temperature class does AC90 use?
A typical 90C AC90 cable uses RW90 insulation associated with a 90°C conductor temperature class. Actual allowable ampacity may be limited by terminals, ambient temperature and installation conditions.
Is AC90 CSA certified?
CSA certified AC90 cable should be verified against the exact product model and current certification scope. Buyers should confirm that the cable marking and documentation match the ordered construction.
What does cUL mean on AC90?
cUL AC90 cable refers to Canadian certification under the applicable certification program and Canadian standard scope. The exact authorized mark must match the current product certification.
 

 

Hot Tags: ac90 copper wire black red 2c 600v for steel stud wall wiring, China ac90 copper wire black red 2c 600v for steel stud wall wiring manufacturers, suppliers, factory