BX 3 Conductor Aluminum Cable 600V For Canadian Building Projects

BX 3 Conductor Aluminum Cable 600V For Canadian Building Projects
Details:
·Conductor: Aluminum
·Insulation: Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
·Armour: Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
·Voltage Rating: 600V
·Application: Data Center Infrastructure、Large-Scale Equipment Manufacturing、Mining Equipment Manufacturing、Hydropower Plants、Oil Refining Industry、Building Materials Industry、Non-Ferrous Metal Industry
Send Inquiry
Download
Description
Technical Parameters
Certification

Dongguan Greater Wire & Cable Co., Ltd. is one of the leading manufacturers and suppliers of bx 3 conductor aluminum cable 600v for canadian building projects in China, also supports customized service. Please rest assured to wholesale durable bx 3 conductor aluminum cable 600v for canadian building projects made in China here from our factory. If you have any enquiry about free sample, please feel free to email us.

 

AC90 3 conductor aluminum wire

PRODUCT REAL SHOT

 

AC90 3 conductor aluminium wire
AC90 three conductor aluminum cable
AC90 three conductor aluminium cable

AC90 three conductor aluminum wire

Cost-efficient armoured wire for contractors distributors and multi-residential projects
For Canadian apartment, condominium, mixed-use and commercial building projects, BX 3 conductor aluminum cable provides a cost-efficient armoured wiring method built around compact aluminum conductors, RW90 XLPE insulation and interlocked metallic protection. A bare aluminum bonding conductor and paper binder complete the internal cable assembly, while the three-conductor design supports common building distribution and three-phase applications when the circuit design is appropriate. GERITEL WIRE manufactures Canadian BX aluminum cable for professional B2B buyers with project quotations, export packing, production scheduling and distributor supply support. The 600V cable is positioned for approved dry indoor wiring, with conductor sizing, voltage drop, termination requirements and local code verified before installation.
PRODUCT SPECIFICATIONS

 

AC90 three conductor aluminium wire

AC90 Cable Overview

 

GERITEL WIRE AC90 cable with its interlocked aluminum armour is designed for aboveground applications. The distinctive features unique to GERITEL WIRE AC90 cable provide significant savings in installation cost and time. Engineered to replace conduit and wire applications, this all-in-one cable assembly offers fewer installation steps. GERITEL WIRE AC90 cable's interlocked aluminum armour protects the conductors from damage before, during and after installation and provides overall flexibility not available with a conduit.

 

GERITEL WIRE AC90 is a factory-produced 600-volt assembly of one to four insulated, phase-identified GERITEL WIRE conductors and one bare bonding conductor inside flexible interlocked aluminum armour. Cross-linked Polyethylene (XLPE) insulated conductors are rated for 90˚C.

 

Multi-conductor AC90 cables are available in sizes 6 AWG to 1500 kcmil. Single-conductor AC90 cables are available in sizes from 1 AWG to 750 kcmil but are not approved for use in hazardous locations. On single-conductor cables, the bonding conductor is applied concentrically around the phase conductor.

 

GERITEL WIRE AC90 cables meet or exceed the requirements of CSA C22.2 No. 38 and C22.2 No. 51 and are approved for use in accordance with the recommendations of the Canadian Electrical Code.

Product Features

 
  • Maximum Conductivity – Compact aluminum alloy conductors carry twice the current per kilogram as equivalent copper conductors
  • Reliable Termination – Conductors terminate safely with industry-standard dual-rated aluminum lugs
  • Exceptional Insulation – The Cross-linked Polyethylene (XLPE) insulation is rated for operating temperatures of -40˚C to +90˚C and offers a higher maximum short-circuit temperature rating than thermoplastic insulation. It is sunlightand moisture-resistant
  • Easy to Install – Lightweight for easier lifting and handling with 25% more flexibility and 40% less springback than copper conductors of equal ampacity
  • Heavy Metals Free insulation is RoHS compliant and environmentally sustainable while providing excellent long-term performance
  • Sequential meter marking

Applications

 

GERITEL WIRE AC90 armoured cable is designed for use in the following open and concealed wiring applications:

  • Service entrance and feeders
  • Power lighting and signal circuits
  • Indoors
  • Where exposed or concealed
  • In cable tray
  • In certain hazardous locations
  • In dry locations and embedded in plaster finish on brick or other masonry except in damp or wet conditions
  • Interior temporary power
SPECIFICATIONS
Conductor Aluminum
Insulation Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
Armour Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
Specifications and Compliance

CSA C22.2 No. 51, Armoured Cables (Type AC90)

CSA C22.2 No. 38 Thermoset-insulated wires and cables (Type RW90)

CSA C22.2 No. 2556 FT4-ST1/UL 1685 Vertical-Tray Flame Test

IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test rated

-40°C Cold Bend and -40°C Cold Impact

Limited Smoke and Halogen Free

AC90 Cable
600 V, CSA Type, -40⁰C to +90⁰C

SIZE
(AWG/kcmil)
BOND SIZE
(AWG/kcmil)
UNDER
ARMOUR
(mm)
OVER
ARMOUR
(mm)
CONDUCTOR
WEIGHT
(kg/km)

CABLE
WEIGHT
(kg/km)

Min Bend Radius
AMPACITY(1)
75°C
AMPACITY(1)
90°C
SINGLE CONDUCTOR
1 4 13.0 18.8 117 324 100 115
1/0 4 14.0 19.8 148 397 120 135
2/0 2 14.9 20.7 186 446 135 150
3/0 2 16.1 22.0 235 508 155 175
4/0 2 17.7 23.6 296 610 180 205
250 1 19.4 25.2 350 688 205 230
300 1 20.7 26.5 420 774 230 260
350 1/0 22.1 27.9 490 889 250 280
400 1/0 23.5 29.3 560 960 270 305
500 2/0 25.8 31.7 700 1161 310 350
600 2/0 28.3 34.1 840 1370 340 385
750 3/0 30.7 36.5 1050 1604 385 435
THREE CONDUCTOR
6 8 14.4 19.4 133 311 50 55
4 6 17.3 22.2 212 422 65 75
2 6 19.6 24.5 316 559 90 100
1 4 22.4 27.3 410 708 100 115
1/0 4 24.0 29.0 502 829 120 135
2/0 4 26.0 30.8 618 977 135 150
3/0 4 28.5 33.4 764 1164 155 175
4/0 4 31.2 36.1 948 1394 180 205
250 2 34.7 41.3 1143 1726 205 230
300 2 37.5 44.2 1354 1991 230 260
350 2 39.8 46.4 1564 2247 250 280
400 2 42.6 49.4 1774 2491 270 305
500 1 46.8 53.6 2218 3013 310 350
600 1 51.1 57.8 2638 3507 340 385
750 1/0 56.3 63.0 3299 4267 385 435
1000 1/0 64.6 71.3 4350 5478 445 500
1500† 2/0 83.9 90.6 6489 8102 520 585
FOUR CONDUCTOR
6 8 16.6 21.5 170 382 50 55
4 6 19.7 24.6 271 521 65 75
2 6 22.5 27.4 409 701 90 100
1 4 25.6 30.6 527 904 100 115
1/0 4 27.6 32.5 650 1050 120 135
2/0 4 29.5 34.4 804 1242 135 150
3/0 4 32.0 36.9 999 1485 155 175
4/0 4 35.0 41.6 1244 1840 180 205
250 2 39.0 45.8 1949 2222 205 230
300 2 42.1 48.8 1774 2570 230 260
350 2 44.6 51.3 2054 2907 250 280
400 2 47.8 54.5 2334 3198 270 305
500 1 52.5 59.2 2919 3878 310 350
600 1 57.2 63.9 3479 4530 340 385
750 1/0 63.0 69.8 4350 5525 385 435
1000 1/0 72.3 79.1 5750 7125 445 500
1500† 2/0 94.0 100.7 8590 10580 520 585

(1) Ampacity based on the 2015 Canadian Electrical Code Part 1 Table 4, Rule 4-004 and Rule 4-006 apply.

† ASTM B231 and ASTM B801 Class B conventional stranding.
All dimensions are nominal and subject to industry standard and manufacturing tolerances.

CERTIFICATIONS

 

3 conductor AC90 aluminum cable

PACKAGING

 

3 conductor AC90 aluminium cable

Roll

3 conductor AC90 aluminum wire

Small Wooden Reel

3 conductor AC90 aluminium wire

Large Wooden Reel

APPLICATION

 

three conductor AC90 aluminum cable
Apartment/Residential Building Electrical Distribution
three conductor AC90 aluminium cable
Commercial Building Electrical Distribution
three conductor AC90 aluminum wire
Energy Storage Systems Industry
CASE

 

three conductor AC90 aluminium wire

Calgary Alberta Multi Storey Apartment Construction Upgrade

AC90 3C aluminum cable

Toronto Ontario Detached House Basement Panel Upgrade

AC90 3C aluminium cable

Vancouver British Columbia Downtown Office Renovation

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

AC90 3C aluminum wire
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

AC90 3C aluminium wire
 
3C AC90 aluminum cable
 
BX aluminum cable
 
BX aluminium cable
 
BX aluminum wire
 
BX aluminium wire
 
GLOBAL CERTIFICATIONS

 

BX aluminum armoured cable

CUSTOMER PHOTOS
 

BX aluminium armoured cable

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

BX aluminum armored cable
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

BX aluminium armored cable
BX aluminum building wire
BX aluminium building wire
BX aluminum building cable
BX aluminium building cable
BX aluminum power cable
BX aluminium power cable
BX aluminum power wire
BX aluminium power wire
BX aluminum conductor cable
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

BX aluminium conductor cable
FAQ

 

Can AC90 aluminum be used in telecom rooms?
Yes. AC90 aluminum cable for telecom room wiring can be used for suitable general building-power circuits in dry telecom rooms, but specialized isolated-ground circuits should be evaluated separately.
Can AC90 aluminum be used in solar facilities?
AC90 aluminum cable for solar facility wiring can be used only for suitable dry indoor auxiliary AC building circuits such as control-room lighting, receptacles or panel feeds. It is not PV DC string wire.
Can AC90 aluminum be used in renewable energy buildings?
Yes. AC90 aluminum cable for renewable energy facilities can support selected dry indoor auxiliary AC circuits in renewable-energy support buildings.
Can AC90 aluminum be used in battery energy storage systems?
AC90 aluminum cable for BESS auxiliary wiring can serve suitable dry indoor auxiliary AC circuits in BESS facilities. It is not a battery interconnect cable and should not be used for battery DC connections.
 

 

Hot Tags: bx 3 conductor aluminum cable 600v for canadian building projects, China bx 3 conductor aluminum cable 600v for canadian building projects manufacturers, suppliers, factory

Send Inquiry