Details:
·Conductor: Class 5 flexible copper conductor
·Insulation: PVC (Polyvinyl Chloride)
·Voltage Rating Uo/U: H05V-K:300/500V ; H07V-K:450/750V
·Temperature Rating: Fixed: -30°C to +70℃ ; Flexed: -5°C to +70℃
·Standards: EN 50525-2-31, EN 60228 ; Flame Retardant according to IEC/EN 60332-1-2 ; UV Resistant
Send Inquiry
Download
Description
Technical Parameters
Certification

single core wire for trunking systems

PRODUCT REAL SHOT

 

PVC flexible wire for trunking systems
false ceiling wiring panel wire
false ceiling wiring internal wiring cable

H07V-K Protected Installation Wire for Indoor Electrical Routing
Although H07V-K contains a flexible Class 5 conductor, its main role is fixed or protected installation rather than continuous movement. This makes fixed installation flexible wire a useful description for panel, conduit and enclosed equipment applications where easy routing is needed during installation. For indoor electrical wiring, the single-core PVC construction can be organised by colour and terminated with suitable accessories. GERITEL WIRE can support contractor, distributor and OEM supply with printing, packing and technical documentation. A single core installation cable should always be selected according to local wiring rules, circuit conditions and the environment in which it will remain after installation.
PRODUCT SPECIFICATIONS

 

single core wire for false ceiling wiring

Applications

 

PVC panel wiring for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers.

SPECIFICATIONS
Voltage Rating Uo/U

H05V-K:300/500V

H07V-K:450/750V

Temperature Rating

Fixed: -30°C to +70°C

Flexed: -5°C to +70°C

Minimum Bending Radius Fixed: 6 x overall diameter
Conductor Class 5 flexible copper conductor
Insulation PVC (Polyvinyl Chloride)
Insulation Colour Red,Black,Blue,Orange,Yellow,White,Green/Yellow,Violet,Pink,Grey,Brown
STANDARDS

EN 50525-2-31,EN 60228

Flame Retardant according to IEC/EN 60332-1-2

UV Resistant

DIMENSIONS

NOMINAL CROSS SECTIONAL AREA

mm²

NOMINAL OVERALL DIAMETER

mm²

NOMINAL WEIGHT

kg/km

H05V-K
0.5 2.20 9.1
0.75 2.40 11.7
1 2.55 14.4
H07V-K
1.5 3.00 20.1
2.5 3.65 31.5
4 4.20 46.2
6 4.80 65.1
10 6.25 109.4
16 7.40 165.2
25 9.40 253.4
35 10.40 345.5
50 12.55 492.4
70 14.10 669.3
95 17.20 910.4
120 17.70 1129.4
150 19.60 1401.0
185 23.00 1741.0
240 26.40 2267.5

CONDUCTORS

NOMINAL CROSS

SECTIONAL AREA

mm²

MAXIMUM DIAMETER

OF WIRES IN CONDUCTOR

mm

MAXIMUM RESISTANCE OF CONDUCTOR AT 20°C

ohms/km

Plain Wires
0.5 0.21 39
0.75 0.21 26
1 0.21 19.5
1.5 0.26 13.3
2.5 0.26 7.98
4 0.31 4.95
6 0.31 3.3
10 0.41 1.91
16 0.41 1.21
25 0.41 0.78
35 0.41 0.554
50 0.41 0.386
70 0.51 0.272
95 0.51 0.206
120 0.51 0.161
150 0.51 0.129
185 0.51 0.106
240 0.51 0.0801

ELECTRICAL CHARACTERISTICS

NOMINAL CROSSS

ECTIONAL AREA

mm²

REFERENCE METHOD A

(ENCLOSED IN

CONDUIT IN THERMALLY

INSULATING WALL ETC)

Amps

REFERENCE METHOD B

(ENCLOSED IN CONDUIT

IN WALL OR IN

TRUNKING ETC)
Amps

REFERENCE METHOD C

(CLIPPED DIRECT)
Amps

REFERENCE METHOD F

(IN FREE AIR OR ONA PERFORATED CABLE TRAY ETC HORIZONTAL OR VERTICAL ETC)

Amps

Touching

Spaced by

one diameter

2 Cables Single-Phase ACor DC or3 Cables Three-Phase AC flat

2 Cables

Single-Phase

ACor DC

3 or 4 Cables

Three-Phase

AC

2 Cables

Single-Phase

ACor DC

3 or 4 Cables

Three-Phase

AC

2 Cables

Single-Phase

AC or DC

3 or 4Cables

Three-Phase

AC

2Cables

SinglePhase

AC or DCflat

3Cables

Three-Phase

ACflat

3 Cables

Three-Phase

ACtrefoil

Horizontal Vertical
1.5 14.5 13.5 17.5 15.5 20 18 - - - - -
2.5 20 18 24 21 27 25 - - - - -
4 26 24 32 28 37 33 - - - - -
6 34 31 41 36 47 43 - - - - -
10 46 42 57 50 65 59 - - - - -
16 61 56 76 68 87 79 - - - - -
25 80 73 101 89 114 104 131 114 110 146 130
35 99 89 125 110 141 129 162 143 137 181 162
50 119 108 151 134 182 167 196 174 167 219 192
70 151 136 192 171 234 214 251 225 216 281 254
95 182 164 232 207 284 261 304 275 264 341 311
120 210 188 269 239 330 303 352 321 308 396 362
150 240 216 300 262 381 349 406 372 356 456 419
185 273 245 341 296 436 400 463 427 409 521 480
240 321 286 400 346 515 472 546 507 485 615 569
CERTIFICATIONS

 

PVC flexible wire for false ceiling wiring

protected fixed wiring panel wire

PACKAGING

 

protected fixed wiring internal wiring cable

Roll

flexible cable for protected fixed wiring

Plastic Reel

single core wire for protected fixed wiring

Small Wooden Reel

APPLICATION

 

PVC flexible wire for protected fixed wiring
Industrial Control Panel
indoor electrical installations panel wire
Renewable Energy Power Connection
indoor electrical installations internal wiring cable

Switchboard Wiring

 

CASE

 

flexible cable for indoor electrical installations

Adelaide Airport Switchboard Upgrade

single core wire for indoor electrical installations

Industrial Main Switchboard Power Distribution

PVC flexible wire for indoor electrical installations

Main Switchboard Flexible Cable Replacement

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

residential distribution boards panel wire
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

residential distribution boards internal wiring cable
 
flexible cable for residential distribution boards
 
single core wire for residential distribution boards
 
commercial building wiring panel wire
 
commercial building wiring internal wiring cable
 
flexible cable for commercial building wiring
 
GLOBAL CERTIFICATIONS

 

single core wire for commercial building wiring

CUSTOMER PHOTOS
 

PVC flexible wire for commercial building wiring

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

electrical installation systems panel wire
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

electrical installation systems internal wiring cable
flexible cable for electrical installation systems
single core wire for electrical installation systems
PVC flexible wire for electrical installation systems
wire for modular houses
cable for modular houses
flexible panel wire for modular houses
single core PVC cable for modular houses
internal wiring wire for modular houses
wire for prefabricated houses
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

cable for prefabricated houses
FAQ

 

Can H07V-K be used inside switchgear?
Yes, switchgear internal wiring is one of the common applications for H07V-K, especially control, indication, relay and auxiliary circuits. Main power connections may require different conductor sizing, construction or installation rules. GERITEL WIRE can review the buyer's drawing, circuit duty and target market before quotation, helping prevent a model mismatch before production.
Can H07V-K be used in distribution boards?
H07V-K can be used as distribution board wire for suitable internal and auxiliary connections where local rules permit flexible single cores. Do not assume it is the correct main feeder for every board. GERITEL WIRE supports technical clarification and sample confirmation, which is useful when a panel builder needs to verify stripping, routing or terminal compatibility before a bulk order.
Can H07V-K be used for metering circuits in a switchboard?
Yes, metering panel wire is a suitable application when the circuit is within the product rating and does not require special screening. Use clear wire numbering and colour coding to reduce commissioning errors. For distributors, GERITEL WIRE can plan repeat supply by colour and packaging format so warehouse stock is easier to manage across different customer applications.
Can I use H07V-K for contactor coil wiring?
H07V-K works well as contactor control wire for suitable coil and auxiliary circuits inside panels. Verify control voltage, protection and terminal requirements rather than selecting only by conductor size. GERITEL WIRE applies incoming-material and finished-product quality controls and can discuss available inspection records or project documentation for the ordered construction.

 

Hot Tags: fixed wiring cable h07v-k for protected electrical systems, China fixed wiring cable h07v-k for protected electrical systems manufacturers, suppliers, factory, HO7V-K

Send Inquiry