EXVB Power Cable Alternative For Belgian 0.6/1kV Distribution

EXVB Power Cable Alternative For Belgian 0.6/1kV Distribution
Details:
·Conductor:RE: Class 1 solid copper conductor RM: Class 2 stranded circular or circular compacted SM: Class 2 stranded sectoral shaped
·Insulation: XLPE (Cross-Linked Polyethylene)
·Bedding: PVC (Polyvinyl Chloride)
·Sheath: PVC (Polyvinyl Chloride)
·Voltage Rating Uo/U: 0.6/1kV
·Temperature Rating:During installation -5℃ to +50℃ Fixed Installation: -20℃ to +90℃
·Standards:IEC 60502-1, Gen to VDE 0276-603, IEC/EN 60228 Flame retardant according to IEC/EN 60332-1-2
Send Inquiry
Download
Description
Technical Parameters
Certification

Cu XLPE PVC power cable 0.6/1kV current rating Egypt

PRODUCT REAL SHOT

 

U-1000 R2V catalogue France
U-1000 R2V CPR France
U-1000 R2V current rating France

600/1000V copper XLPE PVC unarmoured cable Egypt

Copper feeder cable for Belgian projects with unarmoured XLPE/PVC construction
For procurement lists using the EXVB designation, this page presents a copper, XLPE and PVC construction for technical comparison and project approval. For 600/1000 V distribution, the design brings together annealed copper conductors, XLPE insulation and an unarmoured PVC outer covering. Buyers using the phrase EXVB copper cable factory quotation can compare this exact construction without mixing it with aluminium, armoured, LSZH or Class 5 flexible cable. It is aimed at fixed feeders in service buildings, logistics centres, light industry, site utilities and equipment rooms with suitable route protection. Use is intended for stationary routes with appropriate support and protection, not for repeated flexing, reeling or unsupported direct burial.
PRODUCT SPECIFICATIONS

 

600/1000V copper XLPE PVC unarmoured cable supplier Egypt

Applications

 

These power and fixed wiring cables are used for electricity supply in low voltage installation systems. They are well adapted to underground use in industrial applications with an additional mechanical protection. These cables can be fixed on cable trays, within conduits or fixed to walls.

SPECIFICATIONS
Voltage Rating Uo/U 0.6/1kV
Temperature Rating

During installation -5°C to +50°C

Fixed Installation: -20°C to +90°C

Minimum Bending Radius Fixed: 12 x overall diameter
Conductor

RE: Class 1 solid copper conductor

RM: Class 2 stranded circular or circular compacted

SM: Class 2 stranded sectoral shaped

Insulation XLPE (Cross-Linked Polyethylene)
Bedding PVC (Polyvinyl Chloride)
Sheath PVC (Polyvinyl Chloride)
Core Identification

3 core: Green/Yellow,Blue,Brown4 core

4 core: Green/Yellow,Brown,Black,Grey

5 core: Green/Yellow,Blue,Brown,Black,Grey

7 cores and above: Black cores and,White numbers

Sheath Colour Black
STANDARDS IEC 60502-1, Gen to VDE 0276-603, IEC/EN 60228 Flame retardant according to IEC/EN 60332-1-2

DIMENSIONS

NO. OF
CORES

NOMINALCROSS

SECTIONALAREA

mm²

CONDUCTOR

TYPE

NOMINAL

THICKNESS

OF INSULATION

mm

NOMINAL

THICKNESS

OF SHEATH

mm²

NOMINAL OVERALL

DIAMETER

mm

NOMINAL WEIGHT

kg/km

1 16 RM 0.7 1.8 9.8 216
1 25 RM 0.9 1.8 11.5 318
1 35 RM 0.9 1.8 12.6 415
1 50 RM 1 1.8 14.1 543
1 70 RM 1.1 1.8 15.6 746
1 95 RM 1.1 1.8 17.6 1000
1 120 RM 1.2 1.8 19.2 1239
1 150 RM 1.4 1.8 21.2 1515
1 185 RM 1.6 1.8 23.1 1872
1 240 RM 1.7 1.8 25.8 2403
1 300 RM 1.8 1.8 2.78 2974
1 400 RM 2 1.9 31.1 3834
1 500 RM 2.2 2 34.9 4892
1 630 RM 2.8 2.8 46.6 6544
2 1.5 RE 0.7 1.8 10.1 145
2 2.5 RE 0.7 1.8 10.9 179
2 4 RE 0.7 1.8 11.8 226
2 6 RE 0.7 1.8 12.8 284
2 6 RM 0.7 1.8 13.1 295
2 10 RM 0.7 1.8 15 416
2 16 RM 0.7 1.8 17 581
2 25 RM 0.9 1.8 20.4 859
2 35 RM 0.9 1.8 22.5 1109
3 1.5 RE 0.7 1.8 10.5 162
3 2.5 RE 0.7 1.8 11.4 205
3 4 RE 0.7 1.8 12.4 265
3 6 RE 0.7 1.8 13.4 338
3 10 RM 0.7 1.8 15.8 505
3 16 RM 0.7 1.8 18 719
3 25 RM 0.9 1.8 21.6 1072
3 35 RM 0.9 1.8 23.9 1403
3 50 SM 1 1.9 23.8 1581
3 16/10 SM 0.7 1.8 19.8 875.5
3 25/16 SM 0.9/0.7 1.8 22.4 1223
3 35/16 SM 0.9/0.7 1.8 24.3 1557
3 50/25 SM 1/0.9 1.9 26.9 1863
3 70/35 SM 1.1/0.9 2 30 2594
3 95/50 SM 1.1/1 2.2 33.8 3505
3 120/70 SM 1.2/1.1 2.3 37 4440
3 150/70 SM 1.4/1.1 2.4 41.6 5333
3 185/95 SM 1.6/1.1 2.6 45.8 6701
3 240/120 SM 1.7/1.2 2.8 51.6 8674
3 300/150 SM 1.8/1.4 3 67.2 10624
4 1.5 RE 0.7 1.8 11.3 188
4 2.5 RE 0.7 1.8 12.2 240
4 4 RE 0.7 1.8 13.3 314
4 6 RE 0.7 1.8 14.5 408
4 10 RE 0.7 1.8 17.1 615
4 16 RE 0.7 1.8 19.6 885
4 25 RE 0.9 1.8 23.7 1330
4 35 RE 0.9 1.8 26.2 1758
4 50 SM 1 2 27.1 2082
4 70 SM 1.1 2.1 31.4 2937
4 95 SM 1.1 2.2 35 3955
4 120 SM 1.2 2.4 39.3 4979
4 150 SM 1.4 2.6 43.6 6129
4 185 SM 1.6 2.7 48 7591
4 240 SM 1.7 2.9 53.9 9875
4 300 SM 1.8 2.6 68.9 15124
5 1.5 RE 0.7 1.8 12.1 218
5 2.5 RE 0.7 1.8 13.1 281
5 4 RE 0.7 1.8 14.3 372
5 6 RE 0.7 1.8 15.6 486
5 10 RM 0.7 1.8 18.6 740
5 16 RM 0.7 1.8 21.3 1071
5 25 RM 0.9 1.8 25.9 1619
5 35 RM 0.9 1.8 28.8 2138
5 50 RM 1 2.1 29.4 2578
5 70 RM 1.1 2.2 33.7 3616
5 95 RM 1.1 2.4 38.6 4933
5 120 RM 1.2 2.5 42.6 6153
5 150 RM 1.4 2.7 47.7 7587
5 185 RM 1.6 2.9 52.8 9454
5 240 RM 1.7 3.1 58.7 12242
7 1.5 RE 0.7 1.8 12.9 260
7 2.5 RE 0.7 1.8 14 342
7 4 RE 0.7 1.8 15.4 461
10 1.5 RE 0.7 1.8 15.6 357
10 2.5 RE 0.7 1.8 17.2 475
10 4 RE 0.7 1.8 19 646
12 1.5 RE 0.7 1.8 16.1 394
12 2.5 RE 0.7 1.8 17.6 528
14 1.5 RE 0.7 1.8 16.8 436
14 2.5 RE 0.7 1.8 18.5 592
16 4 RM 0.7 1.8 23 971
19 1.5 RE 0.7 1.8 18.4 543
19 2.5 RE 0.7 1.8 20.3 746
24 1.5 RE 0.7 1.8 21.2 675
24 2.5 RE 0.7 1.8 23.4 931
30 1.5 RE 0.7 1.8 22.3 788
30 2.5 RM 0.7 1.8 26.3 7764
40 1.5 RE 0.7 1.8 24.6 995
40 2.5 RE 0.7 1.9 27.5 1416

CONDUCTORS

Class 1 Solid Conductors for Single-Core and Multi-Core Cables

NOMINAL CROSSS

ECTIONAL AREA

mm²

MAXIMUM RESISTANCE OF CONDUCTOR AT 20°C

ohms/km

Circular, Annealed Copper Conductors
Plain
0.5 36
0.75 24.5
1 18.1
1.5 12.1
2.5 7.41
4 4.61
6 3.08

 

Class 2 Stranded Conductors for Single-Core and Multi-Core Cables

NOMINAL CROSS

SECTIONAL AREA

mm²

MINIMUM NO. OF WIRES IN THE CONDUCTOR

MAXIMUM RESISTANCE OF CONDUCTOR AT 20°C

ohms/km

Circular Circular Compacted Annealed Copper Conductors
Cu Cu Plain Wires
4 7 6 4.51
6 7 6 3.08
10 7 6 1.83
16 7 6 1.15
25 7 6 0.727
35 7 6 0.524
50 19 6 0.387
70 19 12 0.268
95 19 15 0.193
120 37 18 0.153
150 37 18 0.124
185 37 30 0.0991
240 37 34 0.0754
300 61 34 0.0601
400 61 53 0.0470
500 61 53 0.0366

ELECTRICAL CHARACTERISTICS

Current Carrying Capacity at 30°C

NOMINAL CROSS

SECTIONAL AREA

mm²

SINGLE CORE

2-40 CORE

Amps

In Ground In Air In Ground In Air
Flat Trefoil Flat Trefoil
1.5 - - - - 31 24
2.5 - - - - 40 32
4 82 54 57 44 52 42
6 102 67 72 56 64 53
10 136 89 99 77 86 74
16 176 115 131 102 112 98
25 229 148 177 138 145 133
35 275 177 217 170 174 162
50 326 209 265 207 206 197
70 400 256 336 263 254 250
95 480 307 415 325 305 308
120 548 349 485 380 348 359
150 616 393 557 437 392 412
185 698 445 646 507 444 475
240 815 517 774 604 517 564
300 927 663 901 697 585 649
400 1064 749 1060 811 - -
500 1227 843 1252 940 - -

DE-RATING FACTORS

For Ground Temperatures other than 20°C

AIR TEMPERATURE 10°C 15°C 20°C 25°C 30°C 35°C 40°C 45°C 50°C
DE-RATING FACTOR 1.07 1.04 1.00 0.96 0.93 0.89 0.85 0.80 0.76

 

For Air Temperatures other than 30°C

AIR TEMPERATURE 20°C 25°C 30°C 35°C 40°C 45°C 50°C 55°C 60°C
DE-RATING FACTOR 1.08 1.04 1.00 0.96 0.91 0.87 0.82 0.76 0.71
CERTIFICATIONS

 

600/1000V copper XLPE PVC unarmoured cable price Egypt

PACKAGING

 

buy 600/1000V copper XLPE PVC unarmoured cable Egypt

Roll

600/1000V copper XLPE PVC unarmoured cable catalogue Egypt

Small Wooden Reel

600/1000V copper XLPE PVC unarmoured cable wholesale Egypt

Steel Wooden Reel

APPLICATION

 

IEC 60502-1 Cu/XLPE/PVC cable supplier Egypt
High-Rise Commercial Building Main Power Distribution
IEC 60502-1 Cu/XLPE/PVC cable manufacturer Egypt
Industrial Plant Low-Voltage Power Distribution
IEC 60502-1 Cu/XLPE/PVC cable price Egypt

Municipal Water Treatment and Pumping Station Power Supply

 

CASE

 

IEC 60502-1 Cu/XLPE/PVC cable distributor Egypt

Babanusa–Adila Power Transmission Project

buy IEC 60502-1 Cu/XLPE/PVC cable Egypt

Italy Electricity Test Project

IEC 60502-1 Cu/XLPE/PVC cable datasheet Egypt

Oyu Tolgoi Copper Mine Project

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

IEC 60502-1 Cu/XLPE/PVC cable catalogue Egypt
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

XVB cable price Belgium
 
IEC 60502-1 Cu/XLPE/PVC cable current rating Egypt
 
IEC 60502-1 Cu/XLPE/PVC cable wholesale Egypt
 
YMvK copper XLPE PVC cable
 
Cu XLPE PVC power cable 0.6/1kV Zambia
 
Cu XLPE PVC power cable 0.6/1kV supplier Zambia
 
GLOBAL CERTIFICATIONS

 

Cu XLPE PVC power cable 0.6/1kV manufacturer Zambia

CUSTOMER PHOTOS
 

Cu XLPE PVC power cable 0.6/1kV distributor Zambia

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

buy Cu XLPE PVC power cable 0.6/1kV Zambia
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

Cu XLPE PVC power cable 0.6/1kV datasheet Zambia
Cu XLPE PVC power cable 0.6/1kV catalogue Zambia
Cu XLPE PVC power cable 0.6/1kV current rating Zambia
600/1000V copper XLPE PVC unarmoured cable Zambia
600/1000V copper XLPE PVC unarmoured cable manufacturer Zambia
600/1000V copper XLPE PVC unarmoured cable distributor Zambia
600/1000V copper XLPE PVC unarmoured cable datasheet Zambia
600/1000V copper XLPE PVC unarmoured cable current rating Zambia
IEC 60502-1 Cu/XLPE/PVC cable Zambia
EXVB cable catalogue Belgium
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

IEC 60502-1 Cu/XLPE/PVC cable supplier Zambia
FAQ

 

How is XLPE insulation different from PVC insulation?
XLPE is cross-linked and generally offers a higher conductor-temperature capability than standard PVC insulation. Cable selection still depends on the complete construction, installation method, fire strategy, voltage drop and local code. A reliable XLPE insulation versus PVC insulation decision therefore needs an approved construction and installation basis. GERITEL WIRE supports mixed-size project orders with cable-schedule review and practical export drum allocation. Confirm conductor class, core colours, drum lengths and inspection scope before production.
Are fillers used inside multicore YJV cable?
Multicore cables commonly use non-hygroscopic fillers or shaped components to achieve a stable circular assembly. Filler material and arrangement should match the approved design and dimensional requirements. For buyers searching multicore XLPE cable fillers, GERITEL WIRE can provide a marking proof, construction drawing and commercial packing proposal for approval. Use project-specific ampacity and voltage-drop calculations rather than a generic marketing value.
Does an unarmoured multicore cable need an inner sheath?
When customers ask about inner sheath Cu XLPE PVC cable, the practical answer is: Some constructions use a wrapped or extruded inner covering, while others apply the outer sheath over a laid-up assembly with fillers. The applicable standard, cable size and manufacturer design determine the layer arrangement. GERITEL WIRE helps EPC buyers close technical gaps before production so site substitutions are reduced. Where mechanical, fire or environmental duty is higher, request the appropriate alternative construction.
Can large copper conductors be sector-shaped?
Yes, multicore power cables may use shaped conductors to reduce overall diameter and material use. Round or sector geometry affects dimensions, lugs, installation and sometimes the market designation, so it must be shown on the datasheet. GERITEL WIRE treats sector shaped copper power cable as a project-specific requirement, not a label-only substitution. GERITEL WIRE can review destination requirements and separate the standard PVC design from LSZH or armoured alternatives. Include certificate scope and destination-market requirements in the technical approval process.

 

Hot Tags: exvb power cable alternative for belgian 0.6/1kv distribution, China exvb power cable alternative for belgian 0.6/1kv distribution manufacturers, suppliers, factory, XLPE Copper Cable, xlpe unarmoured cable

Send Inquiry