R2V Power Cable For Francophone African Building And Utility Projects

R2V Power Cable For Francophone African Building And Utility Projects
Details:
·Conductor:RE: Class 1 solid copper conductor RM: Class 2 stranded circular or circular compacted SM: Class 2 stranded sectoral shaped
·Insulation: XLPE (Cross-Linked Polyethylene)
·Bedding: PVC (Polyvinyl Chloride)
·Sheath: PVC (Polyvinyl Chloride)
·Voltage Rating Uo/U: 0.6/1kV
·Temperature Rating:During installation -5℃ to +50℃ Fixed Installation: -20℃ to +90℃
·Standards:IEC 60502-1, Gen to VDE 0276-603, IEC/EN 60228 Flame retardant according to IEC/EN 60332-1-2
Send Inquiry
Download
Description
Technical Parameters
Certification

Cu XLPE PVC power cable 0.6/1kV datasheet Uganda

PRODUCT REAL SHOT

 

Cu XLPE PVC power cable 0.6/1kV catalogue Uganda
Cu XLPE PVC power cable 0.6/1kV current rating Uganda
600/1000V copper XLPE PVC unarmoured cable Uganda

600/1000V copper XLPE PVC unarmoured cable manufacturer Uganda

Câble électrique cuivre 0.6/1kV for contractors and distributors in West Africa
Developed for French-language procurement searches, this page connects the R2V trade name with copper XLPE/PVC fixed power cable supply. This 0.6/1 kV unarmoured design uses copper conductors under XLPE insulation with an overall PVC sheath for stationary distribution. Buyers using the phrase fournisseur câble R2V cuivre Afrique can compare this exact construction without mixing it with aluminium, armoured, LSZH or Class 5 flexible cable. Regional distributors, tender contractors and public-project suppliers can request bilingual datasheets, cable schedules and container loading plans. It can serve offices, housing developments, hospitals, schools, substations and industrial compounds when the route does not require an armoured construction.
PRODUCT SPECIFICATIONS

 

600/1000V copper XLPE PVC unarmoured cable price Uganda

Applications

 

These power and fixed wiring cables are used for electricity supply in low voltage installation systems. They are well adapted to underground use in industrial applications with an additional mechanical protection. These cables can be fixed on cable trays, within conduits or fixed to walls.

SPECIFICATIONS
Voltage Rating Uo/U 0.6/1kV
Temperature Rating

During installation -5°C to +50°C

Fixed Installation: -20°C to +90°C

Minimum Bending Radius Fixed: 12 x overall diameter
Conductor

RE: Class 1 solid copper conductor

RM: Class 2 stranded circular or circular compacted

SM: Class 2 stranded sectoral shaped

Insulation XLPE (Cross-Linked Polyethylene)
Bedding PVC (Polyvinyl Chloride)
Sheath PVC (Polyvinyl Chloride)
Core Identification

3 core: Green/Yellow,Blue,Brown4 core

4 core: Green/Yellow,Brown,Black,Grey

5 core: Green/Yellow,Blue,Brown,Black,Grey

7 cores and above: Black cores and,White numbers

Sheath Colour Black
STANDARDS IEC 60502-1, Gen to VDE 0276-603, IEC/EN 60228 Flame retardant according to IEC/EN 60332-1-2

DIMENSIONS

NO. OF
CORES

NOMINALCROSS

SECTIONALAREA

mm²

CONDUCTOR

TYPE

NOMINAL

THICKNESS

OF INSULATION

mm

NOMINAL

THICKNESS

OF SHEATH

mm²

NOMINAL OVERALL

DIAMETER

mm

NOMINAL WEIGHT

kg/km

1 16 RM 0.7 1.8 9.8 216
1 25 RM 0.9 1.8 11.5 318
1 35 RM 0.9 1.8 12.6 415
1 50 RM 1 1.8 14.1 543
1 70 RM 1.1 1.8 15.6 746
1 95 RM 1.1 1.8 17.6 1000
1 120 RM 1.2 1.8 19.2 1239
1 150 RM 1.4 1.8 21.2 1515
1 185 RM 1.6 1.8 23.1 1872
1 240 RM 1.7 1.8 25.8 2403
1 300 RM 1.8 1.8 2.78 2974
1 400 RM 2 1.9 31.1 3834
1 500 RM 2.2 2 34.9 4892
1 630 RM 2.8 2.8 46.6 6544
2 1.5 RE 0.7 1.8 10.1 145
2 2.5 RE 0.7 1.8 10.9 179
2 4 RE 0.7 1.8 11.8 226
2 6 RE 0.7 1.8 12.8 284
2 6 RM 0.7 1.8 13.1 295
2 10 RM 0.7 1.8 15 416
2 16 RM 0.7 1.8 17 581
2 25 RM 0.9 1.8 20.4 859
2 35 RM 0.9 1.8 22.5 1109
3 1.5 RE 0.7 1.8 10.5 162
3 2.5 RE 0.7 1.8 11.4 205
3 4 RE 0.7 1.8 12.4 265
3 6 RE 0.7 1.8 13.4 338
3 10 RM 0.7 1.8 15.8 505
3 16 RM 0.7 1.8 18 719
3 25 RM 0.9 1.8 21.6 1072
3 35 RM 0.9 1.8 23.9 1403
3 50 SM 1 1.9 23.8 1581
3 16/10 SM 0.7 1.8 19.8 875.5
3 25/16 SM 0.9/0.7 1.8 22.4 1223
3 35/16 SM 0.9/0.7 1.8 24.3 1557
3 50/25 SM 1/0.9 1.9 26.9 1863
3 70/35 SM 1.1/0.9 2 30 2594
3 95/50 SM 1.1/1 2.2 33.8 3505
3 120/70 SM 1.2/1.1 2.3 37 4440
3 150/70 SM 1.4/1.1 2.4 41.6 5333
3 185/95 SM 1.6/1.1 2.6 45.8 6701
3 240/120 SM 1.7/1.2 2.8 51.6 8674
3 300/150 SM 1.8/1.4 3 67.2 10624
4 1.5 RE 0.7 1.8 11.3 188
4 2.5 RE 0.7 1.8 12.2 240
4 4 RE 0.7 1.8 13.3 314
4 6 RE 0.7 1.8 14.5 408
4 10 RE 0.7 1.8 17.1 615
4 16 RE 0.7 1.8 19.6 885
4 25 RE 0.9 1.8 23.7 1330
4 35 RE 0.9 1.8 26.2 1758
4 50 SM 1 2 27.1 2082
4 70 SM 1.1 2.1 31.4 2937
4 95 SM 1.1 2.2 35 3955
4 120 SM 1.2 2.4 39.3 4979
4 150 SM 1.4 2.6 43.6 6129
4 185 SM 1.6 2.7 48 7591
4 240 SM 1.7 2.9 53.9 9875
4 300 SM 1.8 2.6 68.9 15124
5 1.5 RE 0.7 1.8 12.1 218
5 2.5 RE 0.7 1.8 13.1 281
5 4 RE 0.7 1.8 14.3 372
5 6 RE 0.7 1.8 15.6 486
5 10 RM 0.7 1.8 18.6 740
5 16 RM 0.7 1.8 21.3 1071
5 25 RM 0.9 1.8 25.9 1619
5 35 RM 0.9 1.8 28.8 2138
5 50 RM 1 2.1 29.4 2578
5 70 RM 1.1 2.2 33.7 3616
5 95 RM 1.1 2.4 38.6 4933
5 120 RM 1.2 2.5 42.6 6153
5 150 RM 1.4 2.7 47.7 7587
5 185 RM 1.6 2.9 52.8 9454
5 240 RM 1.7 3.1 58.7 12242
7 1.5 RE 0.7 1.8 12.9 260
7 2.5 RE 0.7 1.8 14 342
7 4 RE 0.7 1.8 15.4 461
10 1.5 RE 0.7 1.8 15.6 357
10 2.5 RE 0.7 1.8 17.2 475
10 4 RE 0.7 1.8 19 646
12 1.5 RE 0.7 1.8 16.1 394
12 2.5 RE 0.7 1.8 17.6 528
14 1.5 RE 0.7 1.8 16.8 436
14 2.5 RE 0.7 1.8 18.5 592
16 4 RM 0.7 1.8 23 971
19 1.5 RE 0.7 1.8 18.4 543
19 2.5 RE 0.7 1.8 20.3 746
24 1.5 RE 0.7 1.8 21.2 675
24 2.5 RE 0.7 1.8 23.4 931
30 1.5 RE 0.7 1.8 22.3 788
30 2.5 RM 0.7 1.8 26.3 7764
40 1.5 RE 0.7 1.8 24.6 995
40 2.5 RE 0.7 1.9 27.5 1416

CONDUCTORS

Class 1 Solid Conductors for Single-Core and Multi-Core Cables

NOMINAL CROSSS

ECTIONAL AREA

mm²

MAXIMUM RESISTANCE OF CONDUCTOR AT 20°C

ohms/km

Circular, Annealed Copper Conductors
Plain
0.5 36
0.75 24.5
1 18.1
1.5 12.1
2.5 7.41
4 4.61
6 3.08

 

Class 2 Stranded Conductors for Single-Core and Multi-Core Cables

NOMINAL CROSS

SECTIONAL AREA

mm²

MINIMUM NO. OF WIRES IN THE CONDUCTOR

MAXIMUM RESISTANCE OF CONDUCTOR AT 20°C

ohms/km

Circular Circular Compacted Annealed Copper Conductors
Cu Cu Plain Wires
4 7 6 4.51
6 7 6 3.08
10 7 6 1.83
16 7 6 1.15
25 7 6 0.727
35 7 6 0.524
50 19 6 0.387
70 19 12 0.268
95 19 15 0.193
120 37 18 0.153
150 37 18 0.124
185 37 30 0.0991
240 37 34 0.0754
300 61 34 0.0601
400 61 53 0.0470
500 61 53 0.0366

ELECTRICAL CHARACTERISTICS

Current Carrying Capacity at 30°C

NOMINAL CROSS

SECTIONAL AREA

mm²

SINGLE CORE

2-40 CORE

Amps

In Ground In Air In Ground In Air
Flat Trefoil Flat Trefoil
1.5 - - - - 31 24
2.5 - - - - 40 32
4 82 54 57 44 52 42
6 102 67 72 56 64 53
10 136 89 99 77 86 74
16 176 115 131 102 112 98
25 229 148 177 138 145 133
35 275 177 217 170 174 162
50 326 209 265 207 206 197
70 400 256 336 263 254 250
95 480 307 415 325 305 308
120 548 349 485 380 348 359
150 616 393 557 437 392 412
185 698 445 646 507 444 475
240 815 517 774 604 517 564
300 927 663 901 697 585 649
400 1064 749 1060 811 - -
500 1227 843 1252 940 - -

DE-RATING FACTORS

For Ground Temperatures other than 20°C

AIR TEMPERATURE 10°C 15°C 20°C 25°C 30°C 35°C 40°C 45°C 50°C
DE-RATING FACTOR 1.07 1.04 1.00 0.96 0.93 0.89 0.85 0.80 0.76

 

For Air Temperatures other than 30°C

AIR TEMPERATURE 20°C 25°C 30°C 35°C 40°C 45°C 50°C 55°C 60°C
DE-RATING FACTOR 1.08 1.04 1.00 0.96 0.91 0.87 0.82 0.76 0.71
CERTIFICATIONS

 

buy 600/1000V copper XLPE PVC unarmoured cable Uganda

PACKAGING

 

600/1000V copper XLPE PVC unarmoured cable catalogue Uganda

Roll

600/1000V copper XLPE PVC unarmoured cable wholesale Uganda

Small Wooden Reel

IEC 60502-1 Cu/XLPE/PVC cable supplier Uganda

Steel Wooden Reel

APPLICATION

 

IEC 60502-1 Cu/XLPE/PVC cable manufacturer Uganda
High-Rise Commercial Building Main Power Distribution
IEC 60502-1 Cu/XLPE/PVC cable distributor Uganda
Industrial Plant Low-Voltage Power Distribution
buy IEC 60502-1 Cu/XLPE/PVC cable Uganda

Municipal Water Treatment and Pumping Station Power Supply

 

CASE

 

IEC 60502-1 Cu/XLPE/PVC cable datasheet Uganda

Babanusa–Adila Power Transmission Project

IEC 60502-1 Cu/XLPE/PVC cable catalogue Uganda

Italy Electricity Test Project

IEC 60502-1 Cu/XLPE/PVC cable current rating Uganda

Oyu Tolgoi Copper Mine Project

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

Cu XLPE PVC power cable 0.6/1kV Rwanda
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

Cu XLPE PVC power cable 0.6/1kV supplier Rwanda
 
Cu XLPE PVC power cable 0.6/1kV manufacturer Rwanda
 
Cu XLPE PVC power cable 0.6/1kV distributor Rwanda
 
low voltage XLPE cable 600/1000V South Africa
 
buy Cu XLPE PVC power cable 0.6/1kV Rwanda
 
Cu XLPE PVC power cable 0.6/1kV datasheet Rwanda
 
GLOBAL CERTIFICATIONS

 

Cu XLPE PVC power cable 0.6/1kV catalogue Rwanda

CUSTOMER PHOTOS
 

Cu XLPE PVC power cable 0.6/1kV current rating Rwanda

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

600/1000V copper XLPE PVC unarmoured cable Rwanda
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

600/1000V copper XLPE PVC unarmoured cable manufacturer Rwanda
IEC 60502-1 Cu/XLPE/PVC cable Rwanda
IEC 60502-1 Cu/XLPE/PVC cable supplier Rwanda
IEC 60502-1 Cu/XLPE/PVC cable manufacturer Rwanda
N2XY-O 0.6/1kV supplier Austria
600/1000V copper XLPE PVC unarmoured cable distributor Rwanda
600/1000V copper XLPE PVC unarmoured cable datasheet Rwanda
600/1000V copper XLPE PVC unarmoured cable current rating Rwanda
N2XY-O 0.6/1kV Austria
N2XY-O 0.6/1kV manufacturer Austria
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

IEC 60502-1 Cu/XLPE/PVC cable distributor Rwanda
FAQ

 

Why do many buyers prefer copper instead of aluminium conductors?
When customers ask about copper conductor XLPE power cable, the practical answer is: Copper offers higher conductivity per cross-sectional area and is often preferred where compact dimensions, termination familiarity and stable electrical performance matter. Cost, weight and project rules still influence the final material choice. GERITEL WIRE supports buyers with dimensional data, drum planning and clear technical deviations before order confirmation. Where mechanical, fire or environmental duty is higher, request the appropriate alternative construction.
What is the difference between YJV and YJLV cable?
YJV normally denotes a copper conductor, whereas YJLV denotes aluminium. They are not interchangeable in resistance, size, weight, lug selection or ampacity; the bill of quantities must state the conductor material clearly. GERITEL WIRE treats YJV versus YJLV cable as a project-specific requirement, not a label-only substitution. GERITEL WIRE can align conductor, cores, marking and packing with the approved project schedule. Include certificate scope and destination-market requirements in the technical approval process.
Can this Cu/XLPE/PVC cable be supplied as single-core and multicore?
For single core and multicore XLPE cable: Yes, subject to the approved size range and project construction. Single-core and multicore cables differ in dimensions, magnetic installation considerations, core identification, current rating and termination planning. GERITEL WIRE provides export-focused technical clarification and can coordinate agreed inspection records. A complete BOQ helps prevent price comparison between materially different cable constructions.
What do G, x, J and O mean in European cable names?
In common European usage, G or J indicates a green-yellow protective conductor, while x or O indicates no green-yellow core. The exact notation must follow the national product convention and approved marking schedule. A reliable N2XY J O core identification decision therefore needs an approved construction and installation basis. GERITEL WIRE can prepare an RFQ response covering construction, approximate weight, packaging and document scope. Installation and termination details should be checked by the responsible project engineer.

 

Hot Tags: r2v power cable for francophone african building and utility projects, China r2v power cable for francophone african building and utility projects manufacturers, suppliers, factory, XLPE Copper Cable, xlpe unarmoured cable

Send Inquiry