XVB Cable For Belgian Residential, Commercial And Industrial Feeders

XVB Cable For Belgian Residential, Commercial And Industrial Feeders
Details:
·Conductor:RE: Class 1 solid copper conductor RM: Class 2 stranded circular or circular compacted SM: Class 2 stranded sectoral shaped
·Insulation: XLPE (Cross-Linked Polyethylene)
·Bedding: PVC (Polyvinyl Chloride)
·Sheath: PVC (Polyvinyl Chloride)
·Voltage Rating Uo/U: 0.6/1kV
·Temperature Rating:During installation -5℃ to +50℃ Fixed Installation: -20℃ to +90℃
·Standards:IEC 60502-1, Gen to VDE 0276-603, IEC/EN 60228 Flame retardant according to IEC/EN 60332-1-2
Send Inquiry
Download
Description
Technical Parameters
Certification

buy IEC 60502-1 Cu/XLPE/PVC cable Rwanda

PRODUCT REAL SHOT

 

IEC 60502-1 Cu/XLPE/PVC cable datasheet Rwanda
IEC 60502-1 Cu/XLPE/PVC cable catalogue Rwanda
IEC 60502-1 Cu/XLPE/PVC cable current rating Rwanda

IEC 60502-1 Cu/XLPE/PVC cable current rating Rwanda

Belgium copper XLPE PVC installation cable for 0.6/1kV fixed power circuits
This Belgium-oriented page captures XVB searches from installers and wholesalers sourcing a robust copper power cable for fixed electrical distribution. The offered construction is a copper-conductor, XLPE-insulated and PVC-sheathed cable intended for fixed rather than flexible service. Buyers using the phrase XVB 0.6/1kV copper cable supplier can compare this exact construction without mixing it with aluminium, armoured, LSZH or Class 5 flexible cable. GERITEL WIRE supports production traceability, inspection coordination, labelled export packing and planned deliveries for project phases. Customers can compare conductor sizes, multicore options, sheath dimensions, reel quantities and documentation needed for a quotation or technical submittal.
PRODUCT SPECIFICATIONS

 

Cu XLPE PVC power cable 0.6/1kV supplier Ethiopia

Applications

 

These power and fixed wiring cables are used for electricity supply in low voltage installation systems. They are well adapted to underground use in industrial applications with an additional mechanical protection. These cables can be fixed on cable trays, within conduits or fixed to walls.

SPECIFICATIONS
Voltage Rating Uo/U 0.6/1kV
Temperature Rating

During installation -5°C to +50°C

Fixed Installation: -20°C to +90°C

Minimum Bending Radius Fixed: 12 x overall diameter
Conductor

RE: Class 1 solid copper conductor

RM: Class 2 stranded circular or circular compacted

SM: Class 2 stranded sectoral shaped

Insulation XLPE (Cross-Linked Polyethylene)
Bedding PVC (Polyvinyl Chloride)
Sheath PVC (Polyvinyl Chloride)
Core Identification

3 core: Green/Yellow,Blue,Brown4 core

4 core: Green/Yellow,Brown,Black,Grey

5 core: Green/Yellow,Blue,Brown,Black,Grey

7 cores and above: Black cores and,White numbers

Sheath Colour Black
STANDARDS IEC 60502-1, Gen to VDE 0276-603, IEC/EN 60228 Flame retardant according to IEC/EN 60332-1-2

DIMENSIONS

NO. OF
CORES

NOMINALCROSS

SECTIONALAREA

mm²

CONDUCTOR

TYPE

NOMINAL

THICKNESS

OF INSULATION

mm

NOMINAL

THICKNESS

OF SHEATH

mm²

NOMINAL OVERALL

DIAMETER

mm

NOMINAL WEIGHT

kg/km

1 16 RM 0.7 1.8 9.8 216
1 25 RM 0.9 1.8 11.5 318
1 35 RM 0.9 1.8 12.6 415
1 50 RM 1 1.8 14.1 543
1 70 RM 1.1 1.8 15.6 746
1 95 RM 1.1 1.8 17.6 1000
1 120 RM 1.2 1.8 19.2 1239
1 150 RM 1.4 1.8 21.2 1515
1 185 RM 1.6 1.8 23.1 1872
1 240 RM 1.7 1.8 25.8 2403
1 300 RM 1.8 1.8 2.78 2974
1 400 RM 2 1.9 31.1 3834
1 500 RM 2.2 2 34.9 4892
1 630 RM 2.8 2.8 46.6 6544
2 1.5 RE 0.7 1.8 10.1 145
2 2.5 RE 0.7 1.8 10.9 179
2 4 RE 0.7 1.8 11.8 226
2 6 RE 0.7 1.8 12.8 284
2 6 RM 0.7 1.8 13.1 295
2 10 RM 0.7 1.8 15 416
2 16 RM 0.7 1.8 17 581
2 25 RM 0.9 1.8 20.4 859
2 35 RM 0.9 1.8 22.5 1109
3 1.5 RE 0.7 1.8 10.5 162
3 2.5 RE 0.7 1.8 11.4 205
3 4 RE 0.7 1.8 12.4 265
3 6 RE 0.7 1.8 13.4 338
3 10 RM 0.7 1.8 15.8 505
3 16 RM 0.7 1.8 18 719
3 25 RM 0.9 1.8 21.6 1072
3 35 RM 0.9 1.8 23.9 1403
3 50 SM 1 1.9 23.8 1581
3 16/10 SM 0.7 1.8 19.8 875.5
3 25/16 SM 0.9/0.7 1.8 22.4 1223
3 35/16 SM 0.9/0.7 1.8 24.3 1557
3 50/25 SM 1/0.9 1.9 26.9 1863
3 70/35 SM 1.1/0.9 2 30 2594
3 95/50 SM 1.1/1 2.2 33.8 3505
3 120/70 SM 1.2/1.1 2.3 37 4440
3 150/70 SM 1.4/1.1 2.4 41.6 5333
3 185/95 SM 1.6/1.1 2.6 45.8 6701
3 240/120 SM 1.7/1.2 2.8 51.6 8674
3 300/150 SM 1.8/1.4 3 67.2 10624
4 1.5 RE 0.7 1.8 11.3 188
4 2.5 RE 0.7 1.8 12.2 240
4 4 RE 0.7 1.8 13.3 314
4 6 RE 0.7 1.8 14.5 408
4 10 RE 0.7 1.8 17.1 615
4 16 RE 0.7 1.8 19.6 885
4 25 RE 0.9 1.8 23.7 1330
4 35 RE 0.9 1.8 26.2 1758
4 50 SM 1 2 27.1 2082
4 70 SM 1.1 2.1 31.4 2937
4 95 SM 1.1 2.2 35 3955
4 120 SM 1.2 2.4 39.3 4979
4 150 SM 1.4 2.6 43.6 6129
4 185 SM 1.6 2.7 48 7591
4 240 SM 1.7 2.9 53.9 9875
4 300 SM 1.8 2.6 68.9 15124
5 1.5 RE 0.7 1.8 12.1 218
5 2.5 RE 0.7 1.8 13.1 281
5 4 RE 0.7 1.8 14.3 372
5 6 RE 0.7 1.8 15.6 486
5 10 RM 0.7 1.8 18.6 740
5 16 RM 0.7 1.8 21.3 1071
5 25 RM 0.9 1.8 25.9 1619
5 35 RM 0.9 1.8 28.8 2138
5 50 RM 1 2.1 29.4 2578
5 70 RM 1.1 2.2 33.7 3616
5 95 RM 1.1 2.4 38.6 4933
5 120 RM 1.2 2.5 42.6 6153
5 150 RM 1.4 2.7 47.7 7587
5 185 RM 1.6 2.9 52.8 9454
5 240 RM 1.7 3.1 58.7 12242
7 1.5 RE 0.7 1.8 12.9 260
7 2.5 RE 0.7 1.8 14 342
7 4 RE 0.7 1.8 15.4 461
10 1.5 RE 0.7 1.8 15.6 357
10 2.5 RE 0.7 1.8 17.2 475
10 4 RE 0.7 1.8 19 646
12 1.5 RE 0.7 1.8 16.1 394
12 2.5 RE 0.7 1.8 17.6 528
14 1.5 RE 0.7 1.8 16.8 436
14 2.5 RE 0.7 1.8 18.5 592
16 4 RM 0.7 1.8 23 971
19 1.5 RE 0.7 1.8 18.4 543
19 2.5 RE 0.7 1.8 20.3 746
24 1.5 RE 0.7 1.8 21.2 675
24 2.5 RE 0.7 1.8 23.4 931
30 1.5 RE 0.7 1.8 22.3 788
30 2.5 RM 0.7 1.8 26.3 7764
40 1.5 RE 0.7 1.8 24.6 995
40 2.5 RE 0.7 1.9 27.5 1416

CONDUCTORS

Class 1 Solid Conductors for Single-Core and Multi-Core Cables

NOMINAL CROSSS

ECTIONAL AREA

mm²

MAXIMUM RESISTANCE OF CONDUCTOR AT 20°C

ohms/km

Circular, Annealed Copper Conductors
Plain
0.5 36
0.75 24.5
1 18.1
1.5 12.1
2.5 7.41
4 4.61
6 3.08

 

Class 2 Stranded Conductors for Single-Core and Multi-Core Cables

NOMINAL CROSS

SECTIONAL AREA

mm²

MINIMUM NO. OF WIRES IN THE CONDUCTOR

MAXIMUM RESISTANCE OF CONDUCTOR AT 20°C

ohms/km

Circular Circular Compacted Annealed Copper Conductors
Cu Cu Plain Wires
4 7 6 4.51
6 7 6 3.08
10 7 6 1.83
16 7 6 1.15
25 7 6 0.727
35 7 6 0.524
50 19 6 0.387
70 19 12 0.268
95 19 15 0.193
120 37 18 0.153
150 37 18 0.124
185 37 30 0.0991
240 37 34 0.0754
300 61 34 0.0601
400 61 53 0.0470
500 61 53 0.0366

ELECTRICAL CHARACTERISTICS

Current Carrying Capacity at 30°C

NOMINAL CROSS

SECTIONAL AREA

mm²

SINGLE CORE

2-40 CORE

Amps

In Ground In Air In Ground In Air
Flat Trefoil Flat Trefoil
1.5 - - - - 31 24
2.5 - - - - 40 32
4 82 54 57 44 52 42
6 102 67 72 56 64 53
10 136 89 99 77 86 74
16 176 115 131 102 112 98
25 229 148 177 138 145 133
35 275 177 217 170 174 162
50 326 209 265 207 206 197
70 400 256 336 263 254 250
95 480 307 415 325 305 308
120 548 349 485 380 348 359
150 616 393 557 437 392 412
185 698 445 646 507 444 475
240 815 517 774 604 517 564
300 927 663 901 697 585 649
400 1064 749 1060 811 - -
500 1227 843 1252 940 - -

DE-RATING FACTORS

For Ground Temperatures other than 20°C

AIR TEMPERATURE 10°C 15°C 20°C 25°C 30°C 35°C 40°C 45°C 50°C
DE-RATING FACTOR 1.07 1.04 1.00 0.96 0.93 0.89 0.85 0.80 0.76

 

For Air Temperatures other than 30°C

AIR TEMPERATURE 20°C 25°C 30°C 35°C 40°C 45°C 50°C 55°C 60°C
DE-RATING FACTOR 1.08 1.04 1.00 0.96 0.91 0.87 0.82 0.76 0.71
CERTIFICATIONS

 

Cu XLPE PVC power cable 0.6/1kV manufacturer Ethiopia

PACKAGING

 

Cu XLPE PVC power cable 0.6/1kV distributor Ethiopia

Roll

buy Cu XLPE PVC power cable 0.6/1kV Ethiopia

Small Wooden Reel

Cu XLPE PVC power cable 0.6/1kV datasheet Ethiopia

Steel Wooden Reel

APPLICATION

 

Cu XLPE PVC power cable 0.6/1kV catalogue Ethiopia
High-Rise Commercial Building Main Power Distribution
Cu XLPE PVC power cable 0.6/1kV current rating Ethiopia
Industrial Plant Low-Voltage Power Distribution
600/1000V copper XLPE PVC unarmoured cable Ethiopia

Municipal Water Treatment and Pumping Station Power Supply

 

CASE

 

600/1000V copper XLPE PVC unarmoured cable distributor Ethiopia

Babanusa–Adila Power Transmission Project

600/1000V copper XLPE PVC unarmoured cable manufacturer Ethiopia

Italy Electricity Test Project

600/1000V copper XLPE PVC unarmoured cable datasheet Ethiopia

Oyu Tolgoi Copper Mine Project

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

600/1000V copper XLPE PVC unarmoured cable current rating Ethiopia
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

IEC 60502-1 Cu/XLPE/PVC cable Ethiopia
 
IEC 60502-1 Cu/XLPE/PVC cable supplier Ethiopia
 
IEC 60502-1 Cu/XLPE/PVC cable distributor Ethiopia
 
YMvK copper XLPE PVC cable
 
IEC 60502-1 Cu/XLPE/PVC cable manufacturer Ethiopia
 
buy IEC 60502-1 Cu/XLPE/PVC cable Ethiopia
 
GLOBAL CERTIFICATIONS

 

IEC 60502-1 Cu/XLPE/PVC cable datasheet Ethiopia

CUSTOMER PHOTOS
 

IEC 60502-1 Cu/XLPE/PVC cable catalogue Ethiopia

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

IEC 60502-1 Cu/XLPE/PVC cable current rating Ethiopia
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

Cu XLPE PVC power cable 0.6/1kV Egypt
Cu XLPE PVC power cable 0.6/1kV supplier Egypt
Cu XLPE PVC cable current rating Switzerland
U-1000 R2V France
Cu XLPE PVC power cable 0.6/1kV datasheet Egypt
kabel miedziany XLPE PVC
U-1000 R2V manufacturer France
Cu XLPE PVC power cable 0.6/1kV manufacturer Egypt
Cu XLPE PVC power cable 0.6/1kV distributor Egypt
buy Cu XLPE PVC power cable 0.6/1kV Egypt
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

Cu XLPE PVC power cable 0.6/1kV catalogue Egypt
FAQ

 

Does this cable use Class 1 or Class 2 copper conductors?
Both may be possible depending on conductor size and the applicable design, but Class 2 stranded copper is common for power cables. The order should state conductor class rather than assuming it from the model name. For buyers searching Class 2 copper XLPE PVC cable, GERITEL WIRE supports OEM marking and project packing while keeping certificate claims tied to verified scope. Send the destination, standard, sizes, core arrangement, quantities and installation route for a precise offer.
Is the conductor solid or stranded?
When customers ask about stranded copper conductor power cable, the practical answer is: Small sizes may use solid conductors under an approved standard, while many power-cable sizes use stranded Class 2 copper. The datasheet should identify strand construction and maximum DC resistance. GERITEL WIRE can organize batch traceability, test documentation and shipment identification for project supply. For selection support, provide system voltage, load, route length, installation method and required documents.
Why is XLPE used as the insulation material?
XLPE provides strong dielectric performance and commonly supports a 90°C maximum conductor temperature in normal service for this cable category. Actual ratings depend on the declared design and standard. GERITEL WIRE treats XLPE insulated copper power cable as a project-specific requirement, not a label-only substitution. GERITEL WIRE helps distributors compare the requested model name with the actual Cu/XLPE/PVC construction. The final choice must follow the approved datasheet, local code and installation design.
What is the purpose of the PVC outer sheath?
For PVC sheathed XLPE power cable: The PVC sheath protects the laid-up cores against normal handling and environmental contact within its declared limits. It does not automatically provide armour, low-smoke performance, fire resistance, water blocking or resistance to every chemical. GERITEL WIRE can coordinate third-party inspection when scope and timing are agreed in the purchase order. State any CPR, flame, UV, water or mechanical requirement separately in the enquiry.

 

Hot Tags: xvb cable for belgian residential, commercial and industrial feeders, China xvb cable for belgian residential, commercial and industrial feeders manufacturers, suppliers, factory, XLPE Copper Cable, xlpe unarmoured cable

Send Inquiry