RHH Aluminum Electrical Wire For Panelboards And Electrical Rooms

RHH Aluminum Electrical Wire For Panelboards And Electrical Rooms
Details:
·Conductors: Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800, ASTM B801 and ASTM B836
·Insulation: Cross-linked polyethylene (XLPE) per UL-44 and UL-854. Sunlight-resistant in all colors 8 AWG and larger
·Voltage: 600V/1000V/2000V
Send Inquiry
Download
Description
Technical Parameters
Certification

aluminum RHH cable for energy storage electrical rooms

PRODUCT REAL SHOT

 

UL44 aluminum RHH wire for energy storage electrical rooms
RHH aluminum power cable for energy storage electrical rooms
aluminum RHH wire for renewable energy plants

aluminum RHH cable for renewable energy plants

UL44 Thermoset Wiring for Building Distribution Panels Fixed Feeders and Protected Power Systems
RHH Aluminum Electrical Wire from GERITEL WIRE is intended for protected fixed distribution around panelboards, electrical rooms and building power systems. The stranded aluminum conductor provides practical handling for project installations, while thermoset insulation supports 90°C dry-location performance. Aluminum RHH Panelboard Wire can be used as part of feeder and distribution circuits when RHH conductors are specified by the electrical engineer and installed in approved pathways. GERITEL WIRE supplies Aluminum Electrical RHH Cable with 600V, 1000V and 2000V project options, customized printing, color identification, reel lengths and packaging for panel builders, contractors and distribution partners.
PRODUCT SPECIFICATIONS

 

UL44 aluminum RHH wire for renewable energy plants

APPLICATIONS

 

Type USE-2, RHH or RHW-2 cables with Aluminum Alloy 8000 Series conductors are suitable for use in conduit and raceways installed underground in wet locations, and where condensation and moisture accumulations within the conduit do not exceed 90°C. Permitted for Type USE-2 per UL-854 for applications requiring direct burial. For applications requiring Type RHH or RHW-2, conductor temperatures shall not exceed 90°C in wet or dry locations. Type USE-2 is permitted for 600 volt applications. Type RHH/RHW-2 is permitted for applications up to 1000 volts.

FEATURES

 

10 AWG and larger rated for Sunlight Resistance. Cables comply with UL's FT-2 (horizontal wire flame). On 250 KCMIL and larger, sequential foot markings located every foot for easy measuring. For 1 AWG through 4/0 AWG, sequential foot markings on master reels only unless otherwise specified. 1/0 AWG and larger are rated for cable tray use and comply with UL-1685-Method 1 (70,000 Btu/hr) flame test. Excellent ruggedized and mechanical protection.

SPECIFICATIONS
Standards Underwriters Laboratories® Standards UL-44, UL-854, UL-1581, UL-1685, UL-2556; Compact Stranded Aluminum Alloy 8000 Series
per ASTM B800, ASTM B801,ASTM B836; Federal Specification AA-59544; NEMA WC70/ICEA S-95-658; NEMA RV-4; NFPA 70 (NEC®);
RoHS Compliant; American National Standards Institute; UL-1685 Method 1 Flame Test; ICEA S-81-570;
MasterSpec Division 26 Sections 260519, 260523; VW-1 or IEEE 1202 (FT4) optional.
Conductors Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800, ASTM B801 and ASTM B836
Insulation Cross-linked polyethylene (XLPE) per UL-44 and UL-854. Sunlight-resistant in all colors 8 AWG and larger
Conductors Compact Diameter of
Aluminum Conductor
(in)
XLPE Insulation
Thickness
(in)
Outside
Diameter
(in)
Approximate
Net Weight
(lbs/1000 ft)
Allowable Ampacities
(Amps)1
Standard Packaging
(ft)
Size
(AWG or
KCMIL)
No. of
Strands
75°C 90°C
8 7 0.134 0.060 0.254 32 40 45 500' 1000' 2500' 5000' Reels
6 7 0.169 0.060 0.289 44 50 55 500' 1000' 2500' 5000' Reels
4 7 0.213 0.060 0.333 62 65 75 500' 1000' 2500' 5000' Reels
3 7 0.238 0.060 0.358 78 75 85 500' 1000' 2500' 5000' Reels
2 7 0.268 0.060 0.388 90 90 100 500' 1000' 2500' 5000' Reels
1 7 0.299 0.080 0.459 120 100 115 500' 1000' 2500' 5000' Reels
1/0 7 0.336 0.080 0.496 150 120 135 500' 1000' 2500' 5000' Reels
2/0 12 0.376 0.080 0.536 176 135 150 500' 1000' 2500' 5000' Reels
3/0 15 0.423 0.080 0.583 216 155 175 500' 1000' 2500' 5000' Reels
4/0 19 0.475 0.080 0.635 262 180 205 500' 1000' 2500' 5000' Reels
250 21 0.520 0.095 0.710 320 205 230 500' 1000' 2500' 4000' Reels
300 22 0.570 0.095 0.760 375 230 260 500' 1000' 3500' Reels
350 24 0.616 0.095 0.806 450 250 280 500' 1000' 3000' Reels
400 27 0.659 0.095 0.849 484 270 305 500' 1000' 3000' Reels
500 34 0.736 0.095 0.926 583 310 350 500' 1000' 2500' Reels
600 41 0.813 0.110 1.033 710 340 385 500' 1000' 2000' Reels
700 45 0.877 0.110 1.097 810 375 425 500' 1000' 1500' Reels
750 47 0.908 0.110 1.128 865 385 435 500' 1000' 1500' Reels
900 58 0.999 0.110 1.219 1015 425 480 500' 1000' Reels
1000 61 1.060 0.110 1.280 1096 445 500 500' 1000' Reels
1 Ampacity of conductors are based on the National Electrical Code (NFPA 70) Table 310.15(B)(16). See 110.14(C), 240.4(D) and 310.15(B) for other limitations where applicable.
The above data is approximate and subject to manufacturing tolerances.
CERTIFICATIONS

 

RHH aluminum power cable for renewable energy plants

PACKAGING

 

aluminum RHH wire for solar inverter rooms

Roll

aluminum RHH cable for solar inverter rooms

Small Wooden Reel

UL44 aluminum RHH wire for solar inverter rooms

Large Wooden Reel

APPLICATION

 

RHH aluminum power cable for solar inverter rooms
Underground Conduit Installation
aluminum RHH wire for solar power systems
Conduit Wiring
aluminum RHH cable for solar power systems
Feeder Circuit Wiring
CASE

 

UL44 aluminum RHH wire for solar power systems

Tesla Gigafactory Texas

RHH aluminum power cable for solar power systems

Stanford University California USA

aluminum RHH wire for photovoltaic power systems

Mayo Clinic Hospital, Saint Marys Campus

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

aluminum RHH cable for photovoltaic power systems
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

UL44 aluminum RHH wire for photovoltaic power systems
 
RHH aluminum power cable for photovoltaic power systems
 
aluminum RHH wire for microgrid facilities
 
aluminum RHH cable for microgrid facilities
 
UL44 aluminum RHH wire for microgrid facilities
 
RHH aluminum power cable for microgrid facilities
 
GLOBAL CERTIFICATIONS

 

aluminum RHH wire for EV charging stations

CUSTOMER PHOTOS
 

aluminum RHH cable for EV charging stations

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

UL44 aluminum RHH wire for EV charging stations
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

RHH aluminum power cable for EV charging stations
aluminum RHH wire for EV charging hubs
aluminum RHH cable for EV charging hubs
UL44 aluminum RHH wire for EV charging hubs
RHH aluminum power cable for EV charging hubs
aluminum RHH wire for industrial switchgear
aluminum RHH cable for industrial switchgear
UL44 aluminum RHH wire for industrial switchgear
RHH aluminum power cable for industrial switchgear
aluminum RHH wire for panel shops
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

aluminum RHH wire for panel shops
FAQ

 

Can Aluminum RHH Cable be used in clean energy infrastructure?
Aluminum RHH Cable for clean energy projects can serve protected fixed feeders in renewable generation, energy-storage and charging facilities when the cable type matches the electrical design. Direct PV, battery, outdoor or buried circuits may require additional specialized listings. GERITEL WIRE can review the circuit description before recommending the production specification.
Why use aluminum conductors in large data-center feeders?
Data Center Aluminum RHH Wire can reduce the total conductor weight of large feeder packages, which may simplify logistics and cable handling on high-volume projects. Aluminum conductor sizing, switchgear terminals and pathway space must be engineered correctly. The product is for facility power distribution and should not be confused with network cabling.
Can Aluminum RHH Cable be used for critical power distribution?
Critical Power Aluminum RHH Cable can be used for protected fixed feeder circuits where the critical-power design accepts aluminum RHH conductors. Reliability depends on correct sizing, approved lugs, proper installation and the full system design, not the conductor material alone. Any special low-smoke or fire-performance requirement must be specified separately.
Can Aluminum RHH Wire connect BESS switchgear?
BESS Aluminum RHH feeder wire can be considered for protected fixed connections to facility switchgear when the system design and product listing permit it. This application is different from flexible battery-cell or rack wiring. GERITEL WIRE recommends providing the voltage, conductor size, pathway and equipment information for technical review.

 

Hot Tags: rhh aluminum electrical wire for panelboards and electrical rooms, China rhh aluminum electrical wire for panelboards and electrical rooms manufacturers, suppliers, factory

Send Inquiry