UL44 Aluminum RHH Wire For UPS Rooms And Switchgear

UL44 Aluminum RHH Wire For UPS Rooms And Switchgear
Details:
·Conductors: Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800, ASTM B801 and ASTM B836
·Insulation: Cross-linked polyethylene (XLPE) per UL-44 and UL-854. Sunlight-resistant in all colors 8 AWG and larger
·Voltage: 600V/1000V/2000V
Send Inquiry
Download
Description
Technical Parameters
Certification

RHH aluminum building wire black XLPE insulation

PRODUCT REAL SHOT

 

aluminum RHH wire with color coded thermoset insulation
color coded thermoset insulation aluminum RHH cable
UL44 RHH aluminum wire with color coded thermoset insulation

RHH aluminum building wire color coded thermoset insulation

Lightweight Facility Power Conductor for Critical Electrical Rooms and Protected Distribution Systems
Aluminum RHH Wire for UPS Rooms can support protected facility-side feeder and distribution systems where UL44 RHH conductors are specified by the electrical design. The stranded aluminum conductor helps reduce installed cable weight, while thermoset insulation provides 90°C dry-location service for electrical rooms and switchgear pathways. Aluminum RHH Switchgear Cable is intended for fixed power distribution rather than flexible UPS battery interconnection, so final selection should follow the project pathway and listing requirements. GERITEL WIRE supplies Critical Power Aluminum RHH Wire with multiple voltage options, custom printing, reel lengths, packaging and scheduled project deliveries.
PRODUCT SPECIFICATIONS

 

aluminum RHH wire with compact aluminum building wire construction

APPLICATIONS

 

Type USE-2, RHH or RHW-2 cables with Aluminum Alloy 8000 Series conductors are suitable for use in conduit and raceways installed underground in wet locations, and where condensation and moisture accumulations within the conduit do not exceed 90°C. Permitted for Type USE-2 per UL-854 for applications requiring direct burial. For applications requiring Type RHH or RHW-2, conductor temperatures shall not exceed 90°C in wet or dry locations. Type USE-2 is permitted for 600 volt applications. Type RHH/RHW-2 is permitted for applications up to 1000 volts.

FEATURES

 

10 AWG and larger rated for Sunlight Resistance. Cables comply with UL's FT-2 (horizontal wire flame). On 250 KCMIL and larger, sequential foot markings located every foot for easy measuring. For 1 AWG through 4/0 AWG, sequential foot markings on master reels only unless otherwise specified. 1/0 AWG and larger are rated for cable tray use and comply with UL-1685-Method 1 (70,000 Btu/hr) flame test. Excellent ruggedized and mechanical protection.

SPECIFICATIONS
Standards Underwriters Laboratories® Standards UL-44, UL-854, UL-1581, UL-1685, UL-2556; Compact Stranded Aluminum Alloy 8000 Series
per ASTM B800, ASTM B801,ASTM B836; Federal Specification AA-59544; NEMA WC70/ICEA S-95-658; NEMA RV-4; NFPA 70 (NEC®);
RoHS Compliant; American National Standards Institute; UL-1685 Method 1 Flame Test; ICEA S-81-570;
MasterSpec Division 26 Sections 260519, 260523; VW-1 or IEEE 1202 (FT4) optional.
Conductors Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800, ASTM B801 and ASTM B836
Insulation Cross-linked polyethylene (XLPE) per UL-44 and UL-854. Sunlight-resistant in all colors 8 AWG and larger
Conductors Compact Diameter of
Aluminum Conductor
(in)
XLPE Insulation
Thickness
(in)
Outside
Diameter
(in)
Approximate
Net Weight
(lbs/1000 ft)
Allowable Ampacities
(Amps)1
Standard Packaging
(ft)
Size
(AWG or
KCMIL)
No. of
Strands
75°C 90°C
8 7 0.134 0.060 0.254 32 40 45 500' 1000' 2500' 5000' Reels
6 7 0.169 0.060 0.289 44 50 55 500' 1000' 2500' 5000' Reels
4 7 0.213 0.060 0.333 62 65 75 500' 1000' 2500' 5000' Reels
3 7 0.238 0.060 0.358 78 75 85 500' 1000' 2500' 5000' Reels
2 7 0.268 0.060 0.388 90 90 100 500' 1000' 2500' 5000' Reels
1 7 0.299 0.080 0.459 120 100 115 500' 1000' 2500' 5000' Reels
1/0 7 0.336 0.080 0.496 150 120 135 500' 1000' 2500' 5000' Reels
2/0 12 0.376 0.080 0.536 176 135 150 500' 1000' 2500' 5000' Reels
3/0 15 0.423 0.080 0.583 216 155 175 500' 1000' 2500' 5000' Reels
4/0 19 0.475 0.080 0.635 262 180 205 500' 1000' 2500' 5000' Reels
250 21 0.520 0.095 0.710 320 205 230 500' 1000' 2500' 4000' Reels
300 22 0.570 0.095 0.760 375 230 260 500' 1000' 3500' Reels
350 24 0.616 0.095 0.806 450 250 280 500' 1000' 3000' Reels
400 27 0.659 0.095 0.849 484 270 305 500' 1000' 3000' Reels
500 34 0.736 0.095 0.926 583 310 350 500' 1000' 2500' Reels
600 41 0.813 0.110 1.033 710 340 385 500' 1000' 2000' Reels
700 45 0.877 0.110 1.097 810 375 425 500' 1000' 1500' Reels
750 47 0.908 0.110 1.128 865 385 435 500' 1000' 1500' Reels
900 58 0.999 0.110 1.219 1015 425 480 500' 1000' Reels
1000 61 1.060 0.110 1.280 1096 445 500 500' 1000' Reels
1 Ampacity of conductors are based on the National Electrical Code (NFPA 70) Table 310.15(B)(16). See 110.14(C), 240.4(D) and 310.15(B) for other limitations where applicable.
The above data is approximate and subject to manufacturing tolerances.
CERTIFICATIONS

 

compact aluminum building wire construction aluminum RHH cable

PACKAGING

 

UL44 RHH aluminum wire with compact aluminum building wire construction

Roll

RHH aluminum building wire compact aluminum building wire construction

Small Wooden Reel

stranded aluminum building wire construction aluminum RHH cable

Large Wooden Reel

APPLICATION

 

UL44 RHH aluminum wire with stranded aluminum building wire construction
Underground Conduit Installation
RHH aluminum building wire stranded aluminum building wire construction
Conduit Wiring
compact aluminum feeder conductor aluminum RHH cable
Feeder Circuit Wiring
CASE

 

UL44 RHH aluminum wire with compact aluminum feeder conductor

Tesla Gigafactory Texas

RHH aluminum building wire compact aluminum feeder conductor

Stanford University California USA

aluminum RHH wire with aluminum alloy power conductor

Mayo Clinic Hospital, Saint Marys Campus

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

aluminum alloy power conductor aluminum RHH cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

UL44 RHH aluminum wire with aluminum alloy power conductor
 
RHH aluminum building wire aluminum alloy power conductor
 
aluminum RHH wire with thermoset insulated single conductor
 
thermoset insulated single conductor aluminum RHH cable
 
UL44 RHH aluminum wire with thermoset insulated single conductor
 
RHH aluminum building wire thermoset insulated single conductor
 
GLOBAL CERTIFICATIONS

 

aluminum RHH wire with lightweight aluminum alloy conductor

CUSTOMER PHOTOS
 

lightweight aluminum alloy conductor aluminum RHH cable

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

UL44 RHH aluminum wire with lightweight aluminum alloy conductor
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

RHH aluminum building wire lightweight aluminum alloy conductor
aluminum RHH wire for 90°C dry location wiring
90°C dry location wiring aluminum RHH cable
aluminum RHH wire for 90 degree C building wiring
90 degree C building wiring aluminum RHH cable
aluminum RHH wire for high heat resistant wiring
aluminum RHH wire for lightweight feeder wiring
lightweight feeder wiring aluminum RHH cable
aluminum RHH wire for lower cable weight installation
lower cable weight installation aluminum RHH cable
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

aluminum RHH wire for easier conductor handling
FAQ

 

Is Aluminum RHH Wire the same as PV Wire?
Aluminum RHH Wire vs PV Wire is an important distinction for solar projects. Type PV requires a photovoltaic listing and construction suitable for the solar application, while RHH alone does not make a conductor PV Wire. Some products may carry both designations, but the exact cable marking must confirm that additional approval.
Is Aluminum RHH Cable the same as service entrance cable?
Aluminum RHH Cable vs service entrance cable depends on the product's additional listings. RHH alone is not a universal service-entrance designation. If the conductor will be used for service-entrance or underground service work, the project should specify the required USE-2 or other applicable type and the cable marking should confirm it.
What is the difference between XLPE and PVC insulation?
XLPE Aluminum RHH Wire uses a cross-linked thermoset insulation system, while PVC is a thermoplastic material used in other wire types. XLPE is known for strong heat resistance and stable performance at elevated temperature. The correct insulation should be chosen from the required cable type, voltage, environment and standard rather than material preference alone.
What is the difference between compact and concentric aluminum stranding?
compact stranded Aluminum RHH Wire uses compressed strands to create a denser, more uniform conductor profile. Conventional concentric stranding may have a larger overall diameter for the same conductor area. The practical differences include finished diameter, flexibility and pulling behavior, so use the manufacturer's dimensions for pathway planning.

 

Hot Tags: ul44 aluminum rhh wire for ups rooms and switchgear, China ul44 aluminum rhh wire for ups rooms and switchgear manufacturers, suppliers, factory

Send Inquiry