2×35+1×10E 0.6/1kV Flexible Power Cable 2C+E

2×35+1×10E 0.6/1kV Flexible Power Cable 2C+E
Details:
·Standard: AS/NZS 5000.1;AS/NZS 3808; AS/NZS 4507
·Voltage: 0.6/1kV
·Conductor: Plain Annealed Copper (Class 5) to AS/NZS 1125
·Insulation: X-HF-110 (Natural)
·Sheath: HFS-110-TP UV Resistant (Orange)
·Flame Propagation: IEC 60332-3 cat A IEC 60332-1
·Green Star: PVC Free
Send Inquiry
Download
Description
Technical Parameters
Certification

2×35+1×10E elastomer cable

PRODUCT REAL SHOT

 

2×35+1×10E 110°C elastomer cable
2×35+1×10E 110C elastomer cable
2×35+1×10E SAA cable

2×35+1×10E 2 core + earth cable

Industrial Plant 2C+E Feeder Cable with 110°C Rating
The 2×35+1×10E elastomer power cable is developed for protected industrial and building circuits requiring flexible handling, reliable earthing and a 110°C conductor rating. Its Class 5 annealed copper multicore cable construction supports neater bends and terminations in MCC rooms, switchboards and process-area service panels. X-HF-110 core insulation and an HFS-110-TP sheath form an LSHF cable for factory distribution with low-smoke, halogen-free and flame-retardant performance. It can be specified as a fixed installation cable for equipment feeders, submains, conduit routes, trenches and protected ducts. GERITEL WIRE assists with specification review, SAA documentation, production testing, project labels, drum planning and international shipment.
PRODUCT SPECIFICATIONS

 

2×35+1×10E 2 core and earth cable

Applications

 

Flexible single core X-HF-110 insulated and HFS-110-TP sheathed cable for mains, submains and subcircuits unenclosed, enclosed in conduit or in underground ducts for building and industrial plants where not subject to mechanical damage. Suitable where space is at a premium and/or where conditions of overload may occur.

SPECIFICATIONS
Approvals Suitable for fixed applications only in accordance with AS/NZS 3000+AS/NZS 5000.1
Behaviour in flame and fire: Flame propagation - AS/NZS IEC 60332-1
Temperature range

Maximum operating temperature: +110°C

Minimum operating temperature: -25°C

Minimum bending radius

Installed cables: 4D

During installation: 6D

Resistance to

Chemical exposure: OccasionaI

Mechanical impact: Light

Water exposure: Uccasional condensation

Solar radiation and weather exposure:Occasional

Cable design

Conductor: Flexible bunched annealed copper conductor to A5/NZ5 1125 (Class 5).

Insulation: X-HF-110 Colour:Natural

Sheath: HFS-110-TP Colour: Orange

Installation conditions

In free air

In conduit

In trench

In duct

Core x cross-

section

mm²

Conductor

Diameter

Nominal insulation

thickness

Nominal

sheath

thickness
mm

Approx.

overall

diamete
mm

Approx.

weight

kg/km

phase

mm

earth

mm

phase

mm

earth

mm

2x10+1x4E 0.40 0.30 0.7 0.7 1.8 16.3 385
2x16+1x6E 0.40 0.30 0.7 0.7 1.8 17.4 515
2x25+1x6E 0.40 0.30 0.9 0.7 1.8 19.9 708
2x35+1x10E 0.40 0.40 0.9 0.7 1.8 22.9 969
2x50+1x16E 0.40 0.40 1.0 0.7 1.8 26.4 1344
2x70+1x25E 0.50 0.40 1.1 0.9 1.8 30.6 1867
2x95+1x25E 0.50 0.40 1.1 0.9 1.9 33.3 2313
2x120+1x35E 0.50 0.40 1.2 0.9 2.0 37.2 2945
2x150+1x50E 0.50 0.40 1.4 1.0 2..1 41.7 3718
2x185+1x70E 0.50 0.50 1.6 1.1 2.3 46.6 4634
2x240+1x95E 0.50 0.50 1.7 1.1 2.4 52.5 6015
mm²

Reactance

at 50Hz

(ohm/km)

Current Rating (A)

Electrical
Characteristics

Spaced

Touching surface

Metallic wiring

enclosure
in air

Underground

duct

one duct

Maximum DC

Resistance 20°C

Ω/km

10 0.0810 94 88 75 84 1.91
16 0.0779 124 116 100 109 1.21
25 0.0783 163 154 129 139 0.780
35 0.0761 202 190 163 171 0.554
50 0.0754 254 238 202 209 0.386
70 0.0744 318 299 257 259 0.272
95 0.0729 381 357 303 304 0.206
120 0.0723 450 421 362 357 0.161
150 0.0728 515 482 412 403

0.129

185 0.0730 586 547 474 456 0.106
240 0.0722 698 625 577 611 0.0801
CERTIFICATIONS

 

2×35+1×10E LSZH cable

2×35+1×10E LSHF cable

PACKAGING

 

2×35+1×10E 0.6/1kV cable

Plastic Reel

2×35+1×10E X-HF-110 cable

Small Wooden Reel

2×35+1×10E HFS-110-TP cable

Large Wooden Reel

APPLICATION

 

2×35+1×10E flexible power cable
Industrial Equipment and Motor Power Supply
2×35+1×10E mains cable
Switchboard and Distribution Panel Wiring
2×35+1×10E submains cable

Underground Cable Trench and Conduit Installation

 

CASE

 

2×35+1×10E industrial cable

Induction Melting Furnace Power System

2×35+1×10E building cable

Mining Processing Plant MCC and Substation UpgradeModular Homes

2×35+1×10E fixed wiring cable

Steel Mill Walking Beam Furnace Electrical Installation

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

2×35+1×10E multicore cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

2×35+1×10E heat resistant cable
 
2×35+1×10E low fire hazard cable
 
2 core and earth low voltage cable
 
low voltage LSZH power cable
 
110 degree heat resistant cable
 
110°C heat resistant multicore cable
 
GLOBAL CERTIFICATIONS

 

110°C flexible multicore cable

CUSTOMER PHOTOS
 

110°C industrial installation cable

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

110°C building installation cable
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

heat resistant 2 core earth cable
high temperature 2C+E cable
high temperature low smoke cable
halogen free power cable 2C+E
halogen free multicore cable
low smoke zero halogen 2C+E cable
LSOH 2 core and earth cable
LS0H 2 core earth cable
LFH 2 core and earth cable
PVC free 2 core and earth cable
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

flame retardant 2C+E cable
FAQ

 

Are the copper conductors tinned?
The standard construction shown in the product data uses plain annealed copper, not automatically tinned copper. A tinned-copper request changes the construction and must be reviewed separately. GERITEL WIRE states the conductor finish clearly in the 2C+E cable specification before production.
What does X-HF-110 insulation provide?
X-HF-110 is a halogen-free insulation system designed for a 110°C conductor temperature class. In an X-HF-110 insulated cable, the material supports heat resistance and low-fire-hazard performance while the electrical design remains subject to the relevant standard. GERITEL WIRE provides the material designation in the datasheet.
What is HFS-110-TP?
HFS-110-TP is the halogen-free thermoplastic sheath material used around the multicore assembly. The HFS-110-TP sheathed cable provides mechanical protection, orange identification and low-smoke flame-performance characteristics. GERITEL WIRE confirms sheath thickness and overall diameter for the ordered size.
Is the cable PVC-free?
The current X-HF-110/HFS-110-TP construction is described as a PVC-free power cable using halogen-free insulation and sheath compounds. GERITEL WIRE can provide the available technical declaration or test documentation so a project team does not rely only on a marketing phrase.

 

Hot Tags: 2×35+1×10e 0.6/1kv flexible power cable 2c+e, China 2×35+1×10e 0.6/1kv flexible power cable 2c+e manufacturers, suppliers, factory, 110 elastomer cables, 110 Single Core Elastomer Cables

Send Inquiry