4x240+1x95E High Current 4C+E Elastomer Main Feeder Cable

4x240+1x95E High Current 4C+E Elastomer Main Feeder Cable
Details:
·Standard: AS/NZS 5000.1;AS/NZS 3808; AS/NZS 4507
·Voltage: 0.6/1kV
·Conductor: Plain Annealed Copper (Class 5) to AS/NZS 1125
·Insulation: X-HF-110 (Natural)
·Sheath: HFS-110-TP UV Resistant (Orange)
·Flame Propagation: IEC 60332-3 cat A IEC 60332-1
·Green Star: PVC Free
Send Inquiry
Download
Description
Technical Parameters
Certification

Dongguan Greater Wire & Cable Co., Ltd. is one of the leading manufacturers and suppliers of 4x240+1x95e high current 4c+e elastomer main feeder cable in China, also supports customized service. Please rest assured to wholesale durable 4x240+1x95e high current 4c+e elastomer main feeder cable made in China here from our factory. If you have any enquiry about free sample, please feel free to email us.

 

4×240+1×95E 110°C elastomer cable

PRODUCT REAL SHOT

 

4×240+1×95E 110C elastomer cable
4×240+1×95E 4C+E cable
4×240+1×95E 4 core and earth cable

4×240+1×95E 4 core + earth cable

Heavy-Duty 3P+N+E Cable for Main LV Distribution
The 4x240+1x95E high temperature 4C+E cable is the largest size in this matrix and is intended for major fixed 0.6/1kV feeders carrying three phases, neutral and protective earth. Four 240mm² flexible Class 5 conductors plus a 95mm² earth make it suitable as a 4C+E cable for LV switchgear where large currents and termination space must be carefully managed. It can also function as a 4C+E power feeder cable between transformers, main boards and high-capacity distribution systems. For clean-energy projects, the same construction may be specified as a 4C+E cable for renewable substations after route, fault and thermal checks. GERITEL WIRE provides SAA support, technical review, test data, custom drum engineering, inspection coordination and export packing.
PRODUCT SPECIFICATIONS

 

4×240+1×95E 3 phase neutral earth cable

Applications

 

Flexible single core X-HF-110 insulated and HFS-110-TP sheathed cable for mains, submains and subcircuits unenclosed, enclosed in conduit or in underground ducts for building and industrial plants where not subject to mechanical damage. Suitable where space is at a premium and/or where conditions of overload may occur.

SPECIFICATIONS
Approvals Suitable for fixed applications only in accordance with AS/NZS 3000+AS/NZS 5000.1
Behaviour in flame and fire: Flame propagation - AS/NZS IEC 60332-1
Temperature range

Maximum operating temperature: +110°C

Minimum operating temperature: -25°C

Minimum bending radius

Installed cables: 4D

During installation: 6D

Resistance to

Chemical exposure: OccasionaI

Mechanical impact: Light

Water exposure: Uccasional condensation

Solar radiation and weather exposure:Occasional

Cable design

Conductor: Flexible bunched annealed copper conductor to A5/NZ5 1125 (Class 5).

Insulation: X-HF-110 Colour:Natural

Sheath: HFS-110-TP Colour: Orange

Installation conditions

In free air

In conduit

In trench

In duct

Core x cross-

section

nx

mm²

Conductor Diameter

mm

Nominal insulation

thicknes

(mm)

Nominal

sheath

thickness
(mm)

Approx.

overall

diamete
(mm)

Approx.

weight

(kg/km)

phase

 

earth

 

phase

 

earth

 

4x10+1x4E 0.40 0.30 0.7 0.7 1.8 19.5 617
4x16+1x6E 0.40 0.30 0.7 0.7 1.8 21.8 868
4x25+1x6E 0.40 0.30 0.9 0.7 1.8 25.6 1245
4x35+1x10E 0.40 0.40 0.9 0.7 1.8 29.2 1694
4x50+1x16E 0.40 0.40 1.0 0.7 1.9 34.0 2376
4x70+1x25E 0.50 0.40 1.1 0.9 2.0 39.5 3316
4x95+1x25E 0.50 0.40 1.1 0.9 2.2 43.6 4208
4x120+1x35E 0.50 0.40 1.2 0.9 2.3 48.7 5343
4x150+1x50E 0.50 0.40 1.4 1.0 2.5 54.6 6720
4x185+1x70E 0.50 0.50 1.6 1.1 2.7 60.7 8283
4x240+1x95E 0.50 0.50 1.7 1.1 2.9 68.6 10802
mm²

Reactance

at 50Hz

(ohm/km)

Current Rating (A)

Electrical
Characteristics

Spaced

Touching surface

Metallic wiring

enclosure
in air

Underground

duct

one duct

Maximum DC

Resistance 20°C

Ω/km

10 0.0810 80 75 65 71 1.91
16 0.0779 106 99 84 91 1.21
25 0.0783 140 131 112 118 0.780
35 0.0761 173 162 137 143 0.554
50 0.0754 218 204 175 178 0.386
70 0.0744 273 255 217 217 0.272
95 0.0729 327 306 263 259 0.206
120 0.0723 387 360 306 298 0.161
150 0.0728 444 413 356 341 0.129
185 0.0730 505 470 402 381 0.106
240 0.0722 602 559 489 453 0.0801
CERTIFICATIONS

 

4×240+1×95E 3P+N+E cable

4×240+1×95E SAA cable

PACKAGING

 

4×240+1×95E SAA approved cable

Plastic Reel

4×240+1×95E X-HF-110 cable

Small Wooden Reel

4×240+1×95E HFS-110-TP cable

Large Wooden Reel

APPLICATION

 

4×240+1×95E LSZH cable
Industrial Equipment and Motor Power Supply
4×240+1×95E LFH cable
Switchboard and Distribution Panel Wiring
4×240+1×95E flexible power cable

Underground Cable Trench and Conduit Installation

 

CASE

 

4×240+1×95E Class 5 copper cable

Induction Melting Furnace Power System

4×240+1×95E 0.6/1kV cable

Mining Processing Plant MCC and Substation UpgradeModular Homes

4×240+1×95E mains cable

Steel Mill Walking Beam Furnace Electrical Installation

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

4×240+1×95E submains cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

4×240+1×95E feeder cable
 
4×240+1×95E switchboard cable
 
4C+E cable for industrial plants
 
4C+E cable for factory power distribution
 
3 phase neutral earth cable for industrial machinery
 
flexible multicore cable for process plants
 
GLOBAL CERTIFICATIONS

 

110C cable for industrial plant rooms

CUSTOMER PHOTOS
 

LSZH cable for manufacturing facilities

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

4C+E equipment feeder cable
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

4C+E cable for factory switchboards
low fire hazard industrial power cable
4C+E cable for fixed industrial equipment
4C+E cable for motor control centres
4C+E cable for motor feeders with control neutral
4C+E cable for industrial motors with auxiliary circuits
flexible cable for MCC feeders
4C+E cable for pump motors with controls
4C+E cable for machine control power
110C cable for motor control circuits
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

LSZH multicore cable for MCC rooms
FAQ

 

Why would a three-phase air conditioner need 4C+E instead of 3C+E?
Some equipment combines a three-phase compressor with single-phase fans, controls or PCBs, so a neutral is required in addition to the three phases and earth. A 4C+E cable for three phase air conditioning can support that arrangement when the equipment wiring diagram confirms it. GERITEL WIRE recommends checking the manufacturer schematic first.
Can I use spare cores in a 4C+E cable for a second circuit?
That is not a simple cable-product decision. Isolation, circuit origin, protective devices, neutral loading and wiring rules all matter. A 4C+E cable for multiple circuits should only be used where the electrical design and applicable rules explicitly permit the arrangement. GERITEL WIRE can confirm cable construction but does not replace circuit-design approval.
Can I use two 2C+E cables instead of one 4C+E cable?
It may be possible in some engineered arrangements, but the circuits, protective earths, identification, isolation and installation method must all be considered. A 4C+E vs 2x2C+E cable comparison should therefore be based on the actual circuit and equipment, not only material cost. GERITEL WIRE can quote both constructions if the project permits alternatives.
Can one core be re-identified as a second neutral?
Core re-identification may be restricted by the wiring rules and by how the circuit is supplied and isolated. A 4C+E cable core identification change should not be made simply for convenience. GERITEL WIRE supplies the agreed core colours/marking and recommends the installer follow the project design and local requirements.

 

Hot Tags: 4x240+1x95e high current 4c+e elastomer main feeder cable, China 4x240+1x95e high current 4c+e elastomer main feeder cable manufacturers, suppliers, factory, 110 elastomer cables, 110 Single Core Elastomer Cables

Send Inquiry