Medium Voltage Unarmoured Cable 3 Core 3.8/6.6Kv Copper Wire

Medium Voltage Unarmoured Cable 3 Core 3.8/6.6Kv Copper Wire
Details:
Compliance
• Conductor resistance AS/NZS 1125
• Insulation resistance AS/NZS 1429.1
• Voltage test AS/NZS 1429.1
Standard and References
• AS/NZS 1429.1
• AS/NZS 1125
• AS/NZS 3808
Send Inquiry
Download
Description
Technical Parameters
Certification

Dongguan Greater Wire & Cable Co., Ltd. is one of the leading manufacturers and suppliers of medium voltage unarmoured cable 3 core 3.8/6.6kv copper wire in China, also supports customized service. Please rest assured to wholesale durable medium voltage unarmoured cable 3 core 3.8/6.6kv copper wire made in China here from our factory. If you have any enquiry about free sample, please feel free to email us.

 

3 Ccore copper MV Cable

 

Medium Voltage Unarmoured Cable 3 Core 3.8/6.6Kv Copper Wire

The outer sheath of medium-voltage unarmoured cable effectively protects the internal structure from the external environment. The outer sheath material has excellent wear resistance, impact resistance and moisture resistance, and can resist chemical corrosion and mechanical damage. In addition, the color and logo design of the outer sheath also facilitates identification and management by construction and maintenance personnel. Sheath materials suitable for outdoor installation can ensure the long-term stability of the cable when exposed.

Min. installation temperature: 0°C

Operating temperature: -25°C to +90°C

Emergency operating temperature: 105°C

(max. operation of 36hrs, at 3 periods for 12 consecutive months use)

Max. Short Circuit Temperature: 250°C

 

Application

 

 

Medium voltage unarmored cable 3 Core 3.8/6.6kV copper wire, with its 3.8/6.6kV rated voltage, is suitable for use in industrial plants, substations, and regional distribution networks where power demands exceed basic residential or commercial needs. This voltage level is particularly well-suited for powering medium-sized industrial machinery, mining operations, water treatment facilities, and renewable energy projects, where stable and efficient transmission is crucial to avoid costly downtime.

MV cable application

 

Feature

 

3C copper MV Cable

 

• Conductor: Stranded Compacted Circular Copper conductor as per AS/NZS 1125

• Conductor Screen: Extruded Semi-conductive compound

• Insulation: XLPE

• Insulation Screen: Extruded Semi-conductive compound

• Longitudinal Water blocking: Water blocking tape below copper screen (Optional)

• Metallic Insulation Screen: Copper Wire Screen + helically applied copper tape (E/F current capacity – Based on requirement)

• binder tape/sheath over assembled cores

• Metallic Sheath: Lead Alloy (optional)

• Outer Sheath: Extruded Polyvinyl Chloride, Colour: Black

• Insect attack Protection: Polyamide Nylon (optional)

(Alternative Sheath: PVC+HDPE Composite Sheath or PVC + Nylon + HDPE (composite sheath with anti-termite properties) or LSZH Outer sheath, and parameters will change accordingly)

 

Certification

 

 

Medium voltage cables have obtained SAA certification, with certification numbers: SAA242046 and SAA250307 (available on the certification website). SAA certification demonstrates that each cable has been assessed to rigorous quality and safety standards. Customers can trace the cables through certification numbers, production records, and batch codes, ensuring authenticity and reducing the risk of counterfeit products. This compliance guarantee demonstrates that the cables meet all key specifications, such as dielectric strength, fire resistance, and mechanical durability, ensuring their safe use in harsh environments such as utilities, infrastructure, and industrial plants.

SAA medium voltage cable

 

Package

 

sta power cable package

 

Factory

 

SAA cable factory

 

Greater Wire Manufacturers has an intelligent and digitalized manufacturing environment. By seamlessly integrating cutting-edge technology, the factory has successfully improved the errors and defects that can occur during the traditional manual assembly process. The shift to digital manufacturing not only improves efficiency, but also demonstrates our commitment to providing customers with products of the highest reliability. The smart factory framework ensures a streamlined and error-free production process, minimizes the possibility of human differences, and increases precision that was previously unattainable. The factory strictly adheres to quality control through precise and automated inspection mechanisms. From the beginning to the final stage of the manufacturing process, products are thoroughly inspected. Digital intelligent image detection and laser technology are used to ensure that each product meets the strict standards set by our company. The commitment to quality extends to our inspection accuracy, with automated production equipment achieving an impressive accuracy of 0.002 mm, exceeding industry benchmarks.

 

Case

 

Company cases

 

Partner

 

greater wire Partner

 

FAQ

 

Q:  What should be paid attention to in the transportation and storage of Medium voltage unarmoured cables?

A: 1. Transportation precautions
1) Prevent mechanical damage: Avoid severe vibration or impact during transportation to prevent the cable from being damaged by crushing, pulling, or squeezing. The cable should be placed on a special reel and fixed with appropriate protective measures.
2) Avoid excessive bending: Avoid excessive bending when the cable is on the reel or unloading to prevent damage to the internal conductor, insulation layer, and sheath material, and ensure that the bending radius is not less than its design requirements.
3) Waterproof protection: Avoid contact with moisture during transportation, especially the exposed ports should be sealed with waterproof covers to prevent moisture from penetrating and affecting the insulation performance.
4) Avoid sunlight and extreme temperatures: Long-term exposure to sunlight or extreme temperature environments will cause cable aging and insulation damage. Avoid sunlight and extreme temperatures during transportation, and ensure that the transportation temperature is within its adaptability range.
5) Avoid heavy object extrusion: Cables should not be stacked with heavy objects to avoid damage to the insulation layer and conductor due to weight extrusion.
2. Storage precautions
1) Ventilated and dry environment: The cable should be stored in a ventilated and dry place, avoid direct sunlight and rain erosion, avoid long-term storage in a humid environment, prevent the insulation layer from getting moldy or metal parts from corroding.
2) Horizontal placement or vertical reel placement: The cable can be placed horizontally and flatly or the reel can be placed vertically to prevent uneven deformation of the cable due to long-term stress.
3) Keep clean: The storage environment should be kept clean and avoid contact with chemicals, especially acid and alkali substances, to prevent corrosion of the cable sheath or insulation layer.
4) Regular inspection: Cables stored for a long time should be inspected regularly to confirm that the cable appearance, sealing and moisture-proof conditions are good, and ensure that there are no external damage or signs of aging.
5) Temperature and humidity control: Try to store the cable in a warehouse with controlled temperature and humidity, avoid high temperature and high humidity environment, to extend its service life.

Q:  Do cables need to be preheated during installation?

A:  Whether cables need to be preheated during installation depends mainly on the ambient temperature and the material of the cable. Generally speaking, when installing cables in low-temperature environments, they need to be preheated to prevent the cable sheath and insulation from becoming brittle and damaged due to low temperature.

If the cable is installed in an ambient temperature below 5°C, especially in a sub-zero temperature environment, the cable material (such as PVC, rubber or polyethylene) may become stiff or brittle. The flexibility of the cable's outer sheath and inner insulation layer is reduced, and it is easy to crack or damage. Preheating can maintain the flexibility of the cable and ensure that it is not damaged during the laying process.

The cable is usually heated for a short time by a heating blanket or heating box to raise its temperature to above 5°C to make it flexible enough for laying.

Q:  Are you a manufacturer or trading company?

A:  We are a professional manufacturer, offering full control over your order from start to finish. From initial design to final delivery, we ensure every step meets the highest standards

 

 

Hot Tags: medium voltage unarmoured cable 3 core 3.8/6.6kv copper wire, China medium voltage unarmoured cable 3 core 3.8/6.6kv copper wire manufacturers, suppliers, factory, 6 35 11Kv 3 Core Copper Medium Voltage Cable, AS NZS1429 1 Single Core Aluminum 19 33kV MV Unarmored Cable, Medium Voltage Unarmoured Cable 3 Core 3 8 6 6Kv Copper Wire, Mv 105 15kv Cable, SAA Single Core 19 36kV Anti Termite Aluminum 35Kv MV Cable, Single Core AL Anti Termite 6 35 12kV Medium Voltage Underground Cable

3C copper MV Cable

3C copper MV power Cable

No. of
Cores
Core Cross
sectional
Area
Nominal Diameter
Under
metallic
screen
Under
metallic
screen
Overall
No.
mm2
mm
mm
mm
3 16 12.9 14.4 35.0
3 25 14.1 15.6 38.0
3 35 15.1 16.6 40.0
3 50 16.2 17.7 43.0
3 70 17.9 19.4 46.0
3 95 19.4 20.9 50.0
3 120 21 22.5 54.0
3 150 22.4 23.9 57.0
3 185 24.1 25.6 61.0
3 240 26.6 28.1 66.0
3 300 29 30.5 72.0
3 400 32.2 33.7 79.0
3 500 36 37.5 88.0
• Above mentioned parameters are based on 3k A/sec earth fault current capacity of copper screen
 
ELECTRICAL CHARACTERISTICS:
No.of Cores
Core Cross sectional Area
Max. DC Resistance at 20˚C
Max. AC Resistance at 90˚C
Approx. Capacitance
Approx. Inductance
Approx.

 Reactance

Continuous Current Rating
Buried direet in ground
In a buried duct
In Air 
No.
mm2
Ω/km
Ω/km
µF/km
mH/km
Ω/km
Amps
3 16 1.15 1.446 0.22 0.613 0.193 101 87 109
3 25 0.727 0.927 0.25 0.583 0.183 129 112 142
3 35 0.524 0.668 0.28 0.563 0.177 153 133 170
3 50 0.387 0.494 0.31 0.546 0.171 181 158 204
3 70 0.268 0.342 0.36 0.515 0.162 221 193 253
3 95 0.193 0.247 0.4 0.501 0.157 262 231 304
3 120 0.153 0.196 0.45 0.485 0.152 298 264 351
3 150 0.124 0.159 0.49 0.477 0.150 334 297 398
3 185 0.0991 0.127 0.54 0.467 0.147 377 336 455
3 240 0.0754 0.097 0.58 0.458 0.144 434 390 531
3 300 0.0601 0.078 0.59 0.452 0.142 489 441 606
3 400 0.047 0.062 0.62 0.445 0.140 553 501 696
3 500 0.0366 0.049 0.66 0.438 0.138 632 574 800
*: Current Ratings are based on IEC 60502-2 & IEC 60287, Max. Conductor Temperature at 90℃, Ambient temperature at 30℃ in Air / at 20℃ in Ground, Thermal resistivity of Soil 1.5 k.m/W & for earthenware ducts 1.2k.m/W and Depth of Laying 0.8m.
Current rating de-rating factors for other than 30℃ ambient air temperature.
20 25 35 40 45 50 55 60
1.08 1.04 0.96 0.91 0.87 0.82 0.76 0.71

 

Current rating de-rating factors for other than 20℃ ground temperature.
10 15 25 30 35 40 45 50
1.07 1.04 0.96 0.93 0.89 0.85 0.80 0.76

 

No.of Cores
Core Cross sectional Area
Max. pulling tension on conductor
Charging Current per phase
Zero sequence impedance
Electric Stress at Conductor Screen
Short circuit rating of Phase conductor
No. mm² kN Amps/Km Ohms/Km kV/mm kA, I sec
3 16 1.12 0.26 2.63 2.1 2.3
3 25 1.75 0.3 2.09 2.0 3.6
3 35 2.45 0.33 1.83 2.0 5.0
3 50 3.5 0.37 1.65 1.9 7.2
3 70 4.9 0.43 1.50 1.9 10.0
3 95 6.65 0.48 1.41 1.8 13.6
3 120 8.4 0.54 1.36 1.8 17.1
3 150 10.5 0.58 1.32 1.8 21.4
3 185 12.95 0.64 1.29 1.7 26.4
3 240 16.8 0.69 1.26 1.7 34.3
3 300 21 0.7 1.24 1.5 42.8
3 400 28 0.74 1.22 1.4 56.9
3 500 35 0.79 1.21 1.3 71.5

 

MV Cable

MV cable 02

Send Inquiry