AC90 Armoured Wire 600V For School And Institutional Projects

AC90 Armoured Wire 600V For School And Institutional Projects
Details:
·Conductor: Solid Soft Copper, ASTM B3 8-2 AWG - Stranded Soft Copper, ASTM B8
·Insulation: Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
·Colour Code: Black, White and Red / Black, White and Green
·Bonding Conductor: Solid ASTM B3 or Stranded ASTM B8 Soft Bare Copper
·Armour: Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
·Voltage Rating: 600V
Send Inquiry
Download
Description
Technical Parameters
Certification

Dongguan Greater Wire & Cable Co., Ltd. is one of the leading manufacturers and suppliers of ac90 armoured wire 600v for school and institutional projects in China, also supports customized service. Please rest assured to wholesale durable ac90 armoured wire 600v for school and institutional projects made in China here from our factory. If you have any enquiry about free sample, please feel free to email us.

 

AC90 cable for commercial building wiring

PRODUCT REAL SHOT

 

AC90 wire for commercial building wiring
AC90 cable for office building wiring
AC90 cable for office fit out wiring

AC90 wire for office fit out wiring

Copper building cable for classrooms corridors offices and public facilities
For schools, colleges, government buildings and institutional projects, AC90 three conductor wire offers a compact armoured wiring method that combines copper conductivity, RW90 XLPE insulation and interlocked metallic protection in one factory-assembled cable. A bonding conductor and paper binder complete the protected cable core, while the 600V design supports a broad range of dry indoor building circuits. GERITEL WIRE manufactures AC90 institutional building cable for distributors, contractors, modular builders and project buyers requiring stable factory supply. Custom product identification, packaging, documentation and repeat-order planning can be arranged for qualified orders. Final use should match the exact cable certification, circuit design and Canadian electrical requirements.
PRODUCT SPECIFICATIONS

 

AC90 cable for tenant improvement wiring

APPLICATIONS

 

Manufactured, tested and certified in Canada, GERITEL WIRE AC90 armoured building wire is rated FT4-ST1 for -40°C to 90°C. Engineered specifically for demanding environments, superior flammability and smoke emission performance.

For use in ventilated, non-ventilated and ladder-type cable trays.

For dry locations, in ceiling air-handling plenums, exposed or concealed wiring and service entrance above ground.

SPECIFICATIONS
Conductor Solid Soft Copper, ASTM B3 8-2 AWG - Stranded Soft Copper, ASTM B8
Insulation Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
Colour Code Black, White and Red / Black, White and Green
Bonding Conductor Solid ASTM B3 or Stranded ASTM B8 Soft Bare Copper
Armour Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
Specifications and Compliance

CSA C22.2 No. 51, Armoured Cables (Type AC90)

CSA C22.2 No. 38 Thermoset-insulated wires and cables (Type RW90)

CSA C22.2 No. 2556 FT4-ST1/UL 1685 Vertical-Tray Flame Test

IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test rated

-40°C Cold Bend and -40°C Cold Impact

Limited Smoke and Halogen Free

AC90 & ISO-AC90 600V CSA FT4-ST1 LSZH

 

AC90

Power

Conductor

Ground

Conductor

Insulation

Thickness

Armour

O.D

Cable

Weight

Max Pulling

Tension

Min Bend Radius Ampacity
Count AWG AWG in mm in mm lbs/Mft kg/km lbs kg in mm A
2 14 14 0.030 0.76 0.430 10.9 81 120 66 30 6.0 151 25
2 12 14 0.030 0.76 0.454 11.5 99 148 104 47 6.4 164 30
2 10 12 0.030 0.76 0.512 13.0 138 206 166 75 6.9 174 40
3 14 14 0.030 0.76 0.445 11.3 105 156 99 45 6.2 158 25
3 12 14 0.030 0.76 0.490 12.4 130 193 157 71 6.9 174 30
3 10 12 0.030 0.76 0.535 13.6 182 271 249 113 7.5 190 40
3 8/7 10 0.045 1.14 0.714 18.1 309 460 418 190 10.0 254 55
3 6/7 8/7 0.045 1.14 0.770 19.6 417 621 702 318 10.8 274 75
3 4/7 8/7 0.045 1.14 0.940 23.9 601 894 1193 541 13.2 334 95
3 3/7 6/7 0.045 1.14 0.990 25.1 721 1073 1622 736 13.9 352 115
3 2/7 6/7 0.045 1.14 1.040 26.4 891 1326 1922 872 14.6 370 130
4 14 14 0.030 0.76 0.490 12.4 130 193 131 60 6.9 174 20
4 12 14 0.030 0.76 0.535 13.6 166 247 209 95 7.5 190 24
4 10 12 0.030 0.76 0.630 16.0 232 345 332 150 8.8 224 32

 

ISO-AC90

Conductor

Count

Power

Conductor

Ins.Ground

Conductor

Ground

Conductor

Insulation

Thickness

Armour

O.D

Cable

Weight

Max Pulling

Tension

Min Bend Radius Ampacity
AWG AWG AWG in mm in mm lbs/Mft kg/km lbs kg in mm A
2 14 14 14 0.030 0.76 0.440 11.2 105 156 66 30 6.2 157 25
2 12 12 14 0.030 0.76 0.485 12.3 138 206 104 47 6.8 173 30
2 10 10 12 0.030 0.76 0.533 13.5 186 277 166 75 7.5 190 40
3 12 12 14 0.030 0.76 0.535 13.6 165 245 157 71 7.5 190 24
3 10 10 12 0.030 0.76 0.591 15.0 232 346 249 113 8.3 210 32
CERTIFICATIONS

 

AC90 wire for tenant improvement wiring

PACKAGING

 

AC90 cable for retail store wiring

Roll

AC90 wire for retail store wiring

Plastic Reel

AC90 cable for shopping mall wiring

Small Wooden Reel

APPLICATION

 

AC90 wire for shopping mall wiring
Apartment/Residential Building Electrical Distribution
AC90 cable for hotel wiring
Commercial Building Electrical Distribution
AC90 wire for hotel wiring
Industrial Factory Power Distribution
CASE

 

AC90 cable for restaurant interior wiring

Calgary Alberta Multi Storey Apartment Construction Upgrade

AC90 wire for restaurant interior wiring

Toronto Ontario Detached House Basement Panel Upgrade

AC90 cable for school building wiring

Vancouver British Columbia Downtown Office Renovation

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

AC90 wire for school building wiring
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

AC90 cable for college building wiring
 
AC90 wire for college building wiring
 
AC90 cable for university building wiring
 
AC90 wire for university building wiring
 
AC90 cable for library building wiring
 
AC90 wire for library building wiring
 
GLOBAL CERTIFICATIONS

 

AC90 cable for hospital support wiring

CUSTOMER PHOTOS
 

AC90 wire for hospital support wiring

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

AC90 cable for clinic building wiring
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

AC90 wire for clinic building wiring
AC90 cable for medical office wiring
AC90 wire for medical office wiring
AC90 cable for government building wiring
AC90 wire for government building wiring
AC90 cable for municipal building wiring
AC90 wire for municipal building wiring
AC90 cable for community center wiring
AC90 wire for community center wiring
AC90 cable for apartment building wiring
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

AC90 wire for apartment building wiring
FAQ

 

Can 3 conductor AC90 be used for switching circuits?
Yes. AC90 3 conductor branch circuit cable can support selected switching arrangements where three insulated conductors are needed. Final conductor functions must follow the electrical design and local code.
Can AC90 be installed above suspended ceilings?
Yes. AC90 above ceiling wiring is commonly routed in approved dry ceiling spaces, provided the cable is properly supported and protected from damage.
Can AC90 be concealed inside walls?
Yes. AC90 concealed wiring cable can be installed in walls and other dry building cavities where the wiring method is permitted and protected from nails, screws and sharp edges.
Can AC90 be used as exposed wiring?
Yes. AC90 open wiring cable may be installed as exposed wiring in approved dry indoor locations. It must still be protected from severe physical damage.
 

 

Hot Tags: ac90 armoured wire 600v for school and institutional projects, China ac90 armoured wire 600v for school and institutional projects manufacturers, suppliers, factory, ac cable, AC Power Cable

Send Inquiry