14/2 NMD 90 Cable

14/2 NMD 90 Cable
Details:
• NMD90 cables are available in two or three cores with an exposed ground conductor.
• Made of annealed (soft) copper conductors - stranded conductors are compression molded.
• Heat-resistant thermoplastic polyvinyl chloride (PVC) insulation and nylon jacket for individual conductors, PVC jacket for overall construction.
• Conductor colors are white, black, and red (three-core cable).
• Standards: ASTM ; CSA C22.2 No. 48 (non-metallic sheathed cable) ; Canadian Electrical Code.
• Voltage: 300 VOLTS.
• Temperature Range: -25ºC ~ 90ºC.
Send Inquiry
Download
Description
Technical Parameters
Certification
NMD90

 

14/2 NMD 90 Cable

14/2 NMD90 cable features two insulated 14 AWG copper conductors and one bare ground wire, encased in a durable PVC jacket. It has an insulation thickness of 0.86 mm and an approximate jacket thickness of 0.76 mm, with overall dimensions of about 9.86 x 4.88 mm. Rated for a maximum conductor temperature of 90°C and a voltage rating of 300V, it meets UL standards for safe and consistent performance. The recommended installation temperature is -25°C for two-conductor cables, provided proper handling procedures are followed. For best results, material should be stored at temperatures above 0°C for at least 24 hours prior to installation.

 

Application

 

 

14/2 NMD90 cable is suitable for residential and light commercial applications in Canada. It is suitable for exposed wiring in dry areas as well as concealed wiring in dry or damp locations. With an allowable ampacity of 25 amps at 30°C ambient, this cable is commonly used for general-purpose circuits, including indoor lighting, receptacles, and small appliances. Its compliance with the Canadian Electrical Code meets all necessary safety standards for dependable use in interior electrical installations.

NMD90 cable application

 

Certification

 

 

NMD90 cable is UL certified, demonstrating its compliance with the high safety and quality requirements set by North American electrical codes. This certification confirms that the cable has undergone rigorous testing for insulation, thermal stability, and fire resistance. More than just a mark of quality, UL approval is essential for legal distribution and use in both the U.S. and Canadian markets.

nmd90 cable certification

 

Package

 

nmd 90  wire package

 

Factory

 

nmd90 copper wire factory

 

Greater Wire is an NMD90 cable manufacturer. We also offer other Canadian standard cables, UL standard cables, and other wires and cables. The factory has an intelligent and digital production environment, which successfully reduces the errors and defects that may occur in the traditional manual assembly process by seamlessly integrating cutting-edge technologies. The transformation to digital manufacturing not only improves efficiency, but also demonstrates our commitment to providing customers with the highest reliability products. The smart factory framework ensures a streamlined and error-free production process, minimizes the impact of human differences, and improves the accuracy that was previously unattainable. The factory strictly controls quality through precise automated inspection mechanisms. From the beginning to the end of the production process, products are fully inspected. We use digital intelligent image inspection and laser technology, and each product meets the strict standards set by the company. The commitment to quality also extends to the detection accuracy, and the accuracy of the automated production equipment reaches an astonishing 0.002 mm.

 

Case

 

Company cases

 

Partner

 

Greater Wire Partner

 

FAQ

 

Q: What is the maximum voltage for NMD 90 wire?

A:NMD90 wire is rated for a maximum voltage of 300 volts

Q: Can NMD90 be used outside?

A: NMD90 cable is primarily designed for use in residential wiring within dry, indoor environments. While it is suitable for installation in air voids of masonry block or tile walls, it is not recommended for outdoor or direct burial applications.

Q: Under what conditions is type NMD90 cable permitted to be run?

A: Type NMD90 cable is permitted to be run indoor /concealed or exposed locations

 

 

Hot Tags: 14/2 nmd 90 cable, China 14/2 nmd 90 cable manufacturers, suppliers, factory, single core building cable, SAA Approval SDI Cable, silicone wire, nmd90, Kabel H05RR F, Metal Clad Cable

2 CONDUCTOR

No. of
Conductors
AWG Size Insulation
Thickness
Approximate
Diameter
Net Weight
Cond. Bond Wire in. mm. in. mm. LB/MFT KG/KM
2 14 14(1) 0.03 0.76 0.19x 38 4.8x9.7 65 96
2 12 14(1) 0.03 0.76 0.21 x41 5.3x10.4 83 123
2 10 12(1) 0.03 0.76 0.23 x47 5.8x11.9 120 178
2 8 10 (1) 1.14 0.045 8.4 x17.0 0.33 x0.67 212 315
2 6 8 (7) 1.14 0.045 9.6 x20.5 0.38x0.81 335 500
2 4 8 (7) 1.14 0.045 19.500 0.770 435 650
2 3 6 (7) 1.14 0.045 21.900 0.860 575 860
2 2 6 (7) 1.14 0.045 23.500 0.930 675 1010

 

3 CONDUCTOR

No. of
Conductors
AWG Size Insulation
Thickness
Approximate
Diameter
Net Weight
Cond. Bond Wire in. mm. in. mm. LB/MFT KG/KM
3 14 14(1) 0.03 0.760 0.340 8.700 83 123
3 12 14(1) 0.03 0.760 0.360 9.100 104 155
3 10 12(1) 0.03 0.760 0.400 10.200 150 223
3 8 10(1) 0.035 0.890 0.610 15.500 275 418
3 6 8(7) 0.045 1.140 0.900 22.800 400 600
3 3 6(7) 0.045 1.140 0.920 23.400 775 1150
3 2 6(7) 0.045 1.140 0.990 25.000 920 1370
Send Inquiry