- Conductor: Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400
-
Conductor Shield: Semi conducting cross-linked polyethylene (XLPE)
-
Insulation: Thermoset crosslinked polyethylene (XLPE)
-
Insulation Shield: Semi conducting cross-linked polyethylene (XLPE)
-
Metallic Shield: Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap
-
Grounding (Optional): One or three soft annealed bare copper or covered conductors cabled with phase conductors.
-
Assembly: Conductors cabled with non hygroscopic fillers, as required and binder tape
-
Jacket: Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound
Application
3 Core MV cables are widely used in main power and distribution circuits in industrial and commercial facilities, as well as power circuits in power plants, especially in those places where the ground fault current is within the cable shielding tolerance. The cable has excellent durability and high performance, can work stably under a variety of environmental conditions, and is suitable for use in wet or dry environments.
This cable can choose different laying methods according to installation requirements, including in-pipe installation, in-channel laying, overhead laying or direct burial. It provides efficient and reliable power distribution during power transmission, while having the ability to resist electrical interference and mechanical protection to ensure stable operation of the system.

Feature

3 core MV90 cable sunlight resistance has excellent sunlight resistance and is particularly suitable for outdoor laying. For cables with specifications of 1/0 AWG and above, this UV resistance ensures that the cable can be used outdoors for a long time without being affected by UV aging. MV90 cable uses a true triple extrusion system to ensure that each layer of material is extruded evenly, providing stronger electrical performance and mechanical protection. In addition, the cable's closed processing raw material system avoids contact with the external environment during the extrusion process, ensuring the purity and high quality of the cable.
Certification
Our products have passed UL, SAA, TUV, VDE, CE, CB and other certifications. Our company has corresponding certification for each region. We have more than 10 years of experience in foreign trade export, exporting to more than 90 countries around the world, and are familiar with the wire and cable specifications and standards of many countries.

Package

Factory

Dongguan Greater Wire & Cable Co., Ltd., is located in Dongguan City, Guangdong province. It integrates R&D, production, sales and maintenance, focusing on various wires and cables, and providing customized solutions for large-scale infrastructure such as airports, hospitals, factories, and schools in many regions around the world. With advanced production equipment and processes, complete testing equipment, and strong technical strength, the company has developed rapidly after years of hard work and the support of global customers, and has won a high reputation and market share in overseas markets.
Our cables and wires have passed SAA, UL, TUV, CE, and other standard certifications.Our products have gained tremendous traction in the international market and are frequently exported to regions such as Southeast Asia, Australia, the Middle East, Africa, America, and Europe, Sales cover more than 400 cities at home and abroad.
Case

Partner

FAQ
Q: Are you a manufacturer or trading company?
Q: When can I get the price?
Hot Tags: 3 core mv90 cable, China 3 core mv90 cable manufacturers, suppliers, factory, 300 300V 2 3 4 Core H03VV F Cable, HO7RN F Cable, CU XLPE SWA Cable, flexible cable, ul1007 hook up wire, XLPE Copper Cable

MV-90 3C, XLPE Insulated, PVC Jacketed, 5 kV – 35 kV, Copper Tape-Shielded
5 kV XLPE Insulated
| Size |
Number of Strands |
Conductor Diameter |
100% and 133% Insulation Levels (90 mil) | |||||
| Ground Conductor* | Jacket Thickness |
Approximate Outside Diameter |
Approximate Net Weight | |||||
| Copper | Aluminum | Copper | Aluminum | |||||
| AWG or kcmil | in | AWG | mil | in | lb/kft | |||
| 8 | 7 | 0.13 | 8 | - | 80 | 1.15 | 735 | - |
| 6 | 7 | 0.17 | 6 | 6 | 80 | 1.23 | 908 | 734 |
| 4 | 7 | 0.21 | 6 | 4 | 80 | 1.32 | 1126 | 849 |
| 2 | 7 | 0.27 | 6 | 4 | 80 | 1.44 | 1451 | 1010 |
| 1 | 19 | 0.30 | 4 | 4 | 80 | 1.51 | 1704 | 1149 |
| 1/0 | 19 | 0.34 | 4 | 4 | 80 | 1.59 | 1974 | 1273 |
| 2/0 | 19 | 0.38 | 4 | 2 | 110 | 1.74 | 2442 | 1559 |
| 3/0 | 19 | 0.42 | 3 | 2 | 110 | 1.84 | 2882 | 1746 |
| 4/0 | 19 | 0.48 | 3 | 2 | 110 | 1.95 | 3379 | 1974 |
| 250 | 37 | 0.52 | 3 | 2 | 110 | 2.07 | 3852 | 2191 |
| 300 | 37 | 0.57 | 2 | 1 | 110 | 2.18 | 4460 | 2468 |
| 350 | 37 | 0.62 | 2 | 1 | 110 | 2.28 | 5033 | 2707 |
| 400 | 37 | 0.66 | 2 | 1 | 110 | 2.37 | 5595 | 2939 |
| 500 | 37 | 0.74 | 1 | 1/0 | 110 | 2.59 | 6844 | 3524 |
| 600 | 61 | 0.81 | 1 | 1/0 | 140 | 2.84 | 8111 | 4124 |
| 750 | 61 | 0.91 | 1/0 | 2/0 | 140 | 3.05 | 9808 | 4831 |
| 1000 | 61 | 1.06 | 1/0 | 3/0 | 140 | 3.37 | 12536 | 5902 |
8 kV XLPE Insulated
| Size AWG or kcmil |
Number of Strands |
Conductor Diameter |
100% Insulation Levels (115 mil) | 133% Insulation Levels (140 mil) | ||||||||||
| Ground Conductor* | Jacket Thickness |
Approximate Outside Diameter |
Approximate Net Weight | Ground Conductor* | Jacket Thickness |
Approximate Net Weight |
Approximate Net Weight | |||||||
| Cu | Al | Cu | Al | Cu | Al | Cu | Al | |||||||
| in | AWG | mil | in | lb/kft | AWG | mil | in | lb/kft | ||||||
| 6 | 7 | 0.17 | 6 | 6 | 80 | 1.34 | 1007 | 832 | 6 | 6 | 80 | 1.45 | 1112 | 938 |
| 4 | 7 | 0.21 | 6 | 4 | 80 | 1.43 | 1230 | 953 | 6 | 4 | 80 | 1.55 | 1341 | 1064 |
| 2 | 7 | 0.27 | 6 | 4 | 80 | 1.55 | 1562 | 1122 | 6 | 4 | 80 | 1.67 | 1680 | 1240 |
| 1 | 19 | 0.30 | 4 | 4 | 80 | 1.62 | 1820 | 1264 | 4 | 4 | 110 | 1.80 | 2053 | 1498 |
| 1/0 | 19 | 0.34 | 4 | 4 | 110 | 1.76 | 2204 | 1502 | 4 | 4 | 110 | 1.88 | 2338 | 1636 |
| 2/0 | 19 | 0.38 | 4 | 2 | 110 | 1.85 | 2575 | 1691 | 4 | 2 | 110 | 1.96 | 2714 | 1830 |
| 3/0 | 19 | 0.42 | 3 | 2 | 110 | 1.95 | 3000 | 1885 | 3 | 2 | 110 | 2.06 | 3145 | 2030 |
| 4/0 | 19 | 0.48 | 3 | 2 | 110 | 2.06 | 3524 | 2119 | 3 | 2 | 110 | 2.18 | 3675 | 2271 |
| 250 | 37 | 0.52 | 3 | 2 | 110 | 2.19 | 4004 | 2343 | 3 | 2 | 110 | 2.30 | 4163 | 2502 |
| 300 | 37 | 0.57 | 2 | 1 | 110 | 2.29 | 4619 | 2627 | 2 | 1 | 110 | 2.40 | 4784 | 2793 |
| 350 | 37 | 0.62 | 2 | 1 | 110 | 2.39 | 5198 | 2872 | 2 | 1 | 110 | 2.50 | 5369 | 3043 |
| 400 | 37 | 0.66 | 2 | 1 | 110 | 2.48 | 5765 | 3110 | 2 | 1 | 110 | 2.65 | 6034 | 3378 |
| 500 | 37 | 0.74 | 1 | 1/0 | 140 | 2.76 | 7200 | 3880 | 1 | 1/0 | 140 | 2.88 | 7397 | 4077 |
| 600 | 61 | 0.81 | 1 | 1/0 | 140 | 2.95 | 8313 | 4326 | 1 | 1/0 | 140 | 3.07 | 8521 | 4535 |
| 750 | 61 | 0.91 | 1/0 | 2/0 | 140 | 3.16 | 10022 | 5045 | 1/0 | 2/0 | 140 | 3.27 | 10243 | 5266 |
| 1000 | 61 | 1.06 | 1/0 | 2/0 | 140 | 3.49 | 12770 | 6136 | 1/0 | 3/0 | 140 | 3.60 | 13011 | 6376 |
15 kV XLPE Insulated
| Size AWG or kcmil |
Number of Strands |
Conductor Diameter |
100% Insulation Levels (115 mil) | 133% Insulation Levels (140 mil) | ||||||||||
| Ground Conductor* | Jacket Thickness |
Approximate Outside Diameter |
Approximate Net Weight | Ground Conductor* | Jacket Thickness |
Approximate Net Weight |
Approximate Net Weight | |||||||
| Cu | Al | Cu | Al | Cu | Al | Cu | Al | |||||||
| in | AWG | mil | in | lb/kft | AWG | mil | in | lb/kft | ||||||
| 2 | 7 | 0.27 | 6 | 4 | 110 | 1.89 | 1974 | 1533 | 6 | 4 | 110 | 2.09 | 2232 | 1792 |
| 1 | 19 | 0.30 | 4 | 4 | 110 | 1.95 | 2245 | 1689 | 4 | 4 | 110 | 2.16 | 2511 | 1956 |
| 1/0 | 19 | 0.34 | 4 | 4 | 110 | 2.03 | 2536 | 1835 | 4 | 4 | 110 | 2.24 | 2811 | 2109 |
| 2/0 | 19 | 0.38 | 4 | 2 | 110 | 2.12 | 2919 | 2036 | 4 | 2 | 110 | 2.32 | 3203 | 2320 |
| 3/0 | 19 | 0.42 | 3 | 2 | 110 | 2.22 | 3359 | 2244 | 3 | 2 | 110 | 2.42 | 3654 | 2539 |
| 4/0 | 19 | 0.48 | 3 | 2 | 110 | 2.33 | 3899 | 2495 | 3 | 2 | 110 | 2.53 | 4206 | 2802 |
| 250 | 37 | 0.52 | 3 | 2 | 110 | 2.45 | 4397 | 2736 | 3 | 2 | 110 | 2.70 | 4811 | 3150 |
| 300 | 37 | 0.57 | 2 | 1 | 110 | 2.61 | 5118 | 3126 | 2 | 1 | 140 | 2.88 | 5635 | 3644 |
| 350 | 37 | 0.62 | 2 | 1 | 140 | 2.77 | 5887 | 3562 | 2 | 1 | 140 | 2.98 | 6248 | 3923 |
| 400 | 37 | 0.66 | 2 | 1 | 140 | 2.87 | 6477 | 3821 | 2 | 1 | 140 | 3.07 | 6848 | 4192 |
| 500 | 37 | 0.74 | 1 | 1/0 | 140 | 3.03 | 7685 | 4365 | 1 | 1/0 | 140 | 3.24 | 8074 | 4754 |
| 600 | 61 | 0.81 | 1 | 1/0 | 140 | 3.22 | 8825 | 4838 | 1 | 1/0 | 140 | 3.43 | 9235 | 5248 |
| 750 | 61 | 0.91 | 1/0 | 2/0 | 140 | 3.43 | 10564 | 5587 | 1/0 | 2/0 | 140 | 3.63 | 10995 | 6018 |
| 1000 | 61 | 1.06 | 1/0 | 2/0 |
140 |
3.82 | 13536 | 6902 | 1/0 | 3/0 | 140 | 4.02 | 14012 | 7377 |
25 kV XLPE Insulated
| Size AWG or kcmil |
Number of Strands |
Conductor Diameter |
100% Insulation Levels (115 mil) | 133% Insulation Levels (140 mil) | ||||||||||
| Ground Conductor* | Jacket Thickness |
Approximate Outside Diameter |
Approximate Net Weight | Ground Conductor* | Jacket Thickness |
Approximate Net Weight |
Approximate Net Weight | |||||||
| Cu | Al | Cu | Al | Cu | Al | Cu | Al | |||||||
| in | AWG | mil | in | lb/kft | AWG | mil | in | lb/kft | ||||||
| 1 | 19 | 0.30 | 4 | 4 | 110 | 2.33 | 2766 | 2210 | - | - | - | - | - | - |
| 1/0 | 19 | 0.34 | 4 | 4 | 110 | 2.41 | 3073 | 2372 | 4 | 4 | 110 | 2.73 | 3594 | 2892 |
| 2/0 | 19 | 0.38 | 4 | 2 | 110 | 2.50 | 3474 | 2590 | 4 | 2 | 140 | 2.88 | 4189 | 3306 |
| 3/0 | 19 | 0.42 | 3 | 2 | 110 | 2.65 | 4026 | 2911 | 3 | 2 | 140 | 2.98 | 4674 | 3559 |
| 4/0 | 19 | 0.48 | 3 | 2 | 140 | 2.83 | 4769 | 3365 | 3 | 2 | 140 | 3.10 | 5263 | 3859 |
| 250 | 37 | 0.52 | 3 | 2 | 140 | 2.95 | 5303 | 3642 | 3 | 2 | 140 | 3.22 | 5815 | 4153 |
| 300 | 37 | 0.57 | 2 | 1 | 140 | 3.06 | 5965 | 3974 | 2 | 1 | 140 | 3.33 | 6492 | 4500 |
| 350 | 37 | 0.62 | 2 | 1 | 140 | 3.16 | 6588 | 4262 | 2 | 1 | 140 | 3.42 | 7129 | 4803 |
| 400 | 37 | 0.66 | 2 | 1 | 140 | 3.25 | 7196 | 4541 | 2 | 1 | 140 | 3.52 | 7751 | 5095 |
| 500 | 37 | 0.74 | 1 | 1/0 | 140 | 3.41 | 8438 | 5118 | 1 | 1/0 | 140 | 3.68 | 9017 | 5696 |
| 600 | 61 | 0.81 | 1 | 1/0 | 140 | 3.60 | 9617 | 5630 | 1 | 1/0 | 140 | 3.94 | 10405 | 6418 |
| 750 | 61 | 0.91 | 1/0 | 2/0 | 140 | 3.88 | 11577 | 6600 | 1/0 | 2/0 | 140 | 4.15 | 12224 | 7246 |
35 kV XLPE Insulated
| Size AWG or kcmil |
Number of Strands |
Conductor Diameter |
100% Insulation Levels (115 mil) | 133% Insulation Levels (140 mil) | ||||||||||
| Ground Conductor* | Jacket Thickness |
Approximate Outside Diameter |
Approximate Net Weight | Ground Conductor* | Jacket Thickness |
Approximate Net Weight |
Approximate Net Weight | |||||||
| Cu | Al | Cu | Al | Cu | Al | Cu | Al | |||||||
| in | AWG | mil | in | lb/kft | AWG | mil | in | lb/kft | ||||||
| 1/0 | 19 | 0.34 | 4 | 4 | 140 | 2.91 | 3967 | 3266 | 4 | 4 | 140 | 3.25 | 4606 | 3904 |
| 2/0 | 19 | 0.38 | 4 | 2 | 140 | 3.00 | 4394 | 3510 | 4 | 2 | 140 | 3.33 | 5048 | 4164 |
| 3/0 | 19 | 0.42 | 3 | 2 | 140 | 3.10 | 4884 | 3769 | 3 | 2 | 140 | 3.43 | 5556 | 4441 |
| 4/0 | 19 | 0.48 | 3 | 2 | 140 | 3.21 | 5480 | 4076 | 3 | 2 | 140 | 3.55 | 6172 | 4768 |
| 250 | 37 | 0.52 | 3 | 2 | 140 | 3.33 | 6039 | 4378 | 3 | 2 | 140 | 3.67 | 6753 | 5092 |
| 300 | 37 | 0.57 | 2 | 1 | 140 | 3.44 | 6723 | 4731 | 2 | 1 | 140 | 3.77 | 7456 | 5464 |
| 350 | 37 | 0.62 | 2 | 1 | 140 | 3.54 | 7366 | 5040 | 2 | 1 | 140 | 3.94 | 8299 | 5974 |
| 400 | 37 | 0.66 | 2 | 1 | 140 | 3.63 | 7993 | 5338 | 2 | 1 | 140 | 4.03 | 8947 | 6292 |
| 500 | 37 | 0.74 | 1 | 1/0 | 140 | 3.86 | 9448 | 6128 | 1 | 1/0 | 140 | 4.20 | 10260 | 6940 |
| 600 | 61 | 0.81 | 1 | 1/0 | 140 | 4.05 | 10673 | 6687 | 1 | 1/0 | 140 | 4.39 | 11519 | 7532 |
| 750 | 61 | 0.91 | 1/0 | 2/0 | 140 | 4.26 | 12504 | 7527 | 1/0 | 2/0 | 140 | 4.59 | 13387 | 8410 |
The above data are approximate and subject to normal manufacturing tolerances. Where required, the compatibility with glands, connectors, and accessories should be verified using the actual dimensions of the product. Other sizes are available upon request. Ampacities: Refer to the tables at the beginning of the section.
* At the manufacturer's option, Ground Conductor can be divided in three, one in each interstice. Cables that comply with 8 kV 100% can also be marked 5 kV 133%.