35kV Aluminum TR-XLPE/CN/LLDPE MV-90 Primary UD Cable 133% I.L. 420 Mils

35kV Aluminum TR-XLPE/CN/LLDPE MV-90 Primary UD Cable 133% I.L. 420 Mils
Details:
·Aluminum Stranded Conductor(unfilled/filled)
·LLDPE Jacket with 3 Red Stripes
·Insulation Shield
·Conductor Shield
·TR-XLPE Insulation
·Copper Wire Concentric Neutral
·Voltage Rating:15KV-35KV
·Size Range:2AWG~1000kcmil
·Standard:UL1072
·Single core
·Color:black
Send Inquiry
Download
Description
Technical Parameters
Certification

35kV aluminum stranded conductor UD cable

PRODUCT REAL SHOT

 

35kV TR-XLPE insulation LLDPE jacket cable
35kV aluminum medium voltage power cable
35kV power distribution primary cable

35kV Aluminum TR-XLPE/CN/LLDPE MV-90 Primary UD Cable 133% I.L. 420 Mils

35kV Aluminum TR-XLPE/CN/LLDPE MV-90 Primary UD Cable 133% I.L. 420 mils
This 35kV Aluminum TR-XLPE/CN/LLDPE MV-90 Primary UD Cable adopts heavy-duty 420 mils TR-XLPE insulation with 133% insulation level, specially engineered for ungrounded and impedance-grounded medium-voltage underground systems. It features a cost-effective compact aluminum conductor, copper concentric neutral shield, and durable LLDPE outer jacket. The thickened anti-water-tree insulation delivers superior overvoltage tolerance during prolonged ground faults, greatly enhancing operational safety margin. Rated 90°C continuous operation, this robust cable supports direct burial and duct bank installation, ideal for industrial parks, substations and municipal critical power distribution under harsh underground conditions.
PRODUCT SPECIFICATIONS

 

35kV utility MV-90 cable

Product Description

 

The Medium Voltage Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with tree-retardant cross-linked polyethylene (TR-XLPE), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.

Applications

 
  • Suitable for underground primary power applications
  • For wet or dry locations
  • For direct burial or in duct

Features

 
  • High dielectric strength
  • Low moisture absorption
  • Low dielectric loss
  • Excellent resistance to treeing
  • Jacket is sunlight-resistant
  • Designed to operate continuously at a conductor temperature not exceeding

    90°C for normal operations

    130°C for emergency overload

    250°C for short circuit

SPECIFICATIONS

Conductor Count

1 conductor

Conductor

Aluminum 1350 Class B compressed strand (filled or unfilled)

Gauge Sizes

Available in 2 AWG through 1000 kcmil

Conductor Strand Shield

Extruded thermoset semi-conducting polymer over the conductor

Super-Smooth is available upon request

Insulation

Tree-Retardant Cross-linked Polyethylene (TR-XLPE)

Insulation Shield

Extruded thermoset semi-conducting polymer over the insulation

Neutral

Helically applied, annealed, solid bare copper wires

Jacket

Linear Low-Density Polyethylene (LLDPE)

Moisture blocked jacket is available upon on request

Jacket Marking

00000 FT GREATER WIRE XXAWG (KCMIL) (FS) AL 1/C XXKV XXX% INSUL LEVEL XXXMILS TRXLPE AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)

Packaging

Non-returnable wood reels in a variety of lengths and dimensions

Performance Compliances

ASTM B3

ASTM B230

ASTM B231

ICEA S-94-649

ICEA T-31-610 (water block compliance), as needed

ICEA T-34-664 (moisture blocked jacket), as needed
AEIC CS8
UL 1072 (MV-90)

RUS U1

Aluminum Unfilled/Filled, 35kV 133% I.L., 420 mils

Conductor
Size

AWG/Kcmil

Nom.

Conductor
Diameter

in(mm)

Insulation
Diameter

in(mm)

Concentric

Neutral

No. x AWG

Jacket Thickness
in(mm)

Approx.

Overall
Diameter
in(mm)

Approx. Net

Weight
lbs/kft (kg/km)

 Ampacity
Underground Duct Direct Buried
1/6 Neutral
750 0.968(24.6) 1.91 (48.5) 19×14 0.075 (1.9) 2.34(59.4) 2,315(3,445) 480 550
1000 1.117 (28.4) 2.06 (52.3) 25×14 0.075 (1.9) 2.49 (63.2) 2,750 (4,092) 550 615
1250 1.250(31.8) 2.20 (55.9) 31×14 0.075 (1.9) 2.63 (66.8) 3,180(4,732) 625 680
1/3 Reduced Neutral
1/0 0.362(9.2) 1.27 (32.3) 6x14 0.050 (1.3) 1.62 (41.1) 935(1,391) 160 195
2/0 0.405(10.3) 1.31 (33.3) 7x14 0.050 (1.3) 1.66 (42.2) 1,010 (1,503) 185 220
3/0 0.456(11.6) 1.37 (34.8) 9x14 0.050 (1.3) 1.71 (43.4) 1,105 (1,644) 210 250
4/0 0.512 (13.0) 1.42(36.1) 11x14 0.075 (1.9) 1.82 (46.2) 1,270 (1,890) 235 285
250 0.558 (14.2) 1.48 (37.6) 13x14 0.075 (1.9) 1.88 (47.8) 1,375 (2,046) 265 300
350 0.661 (16.8) 1.58 (40.1) 18x14 0.075 (1.9) 1.98 (50.3) 1,615 (2,403) 315 370
500 0.789 (20.0) 1.71 (43.4) 25x14 0.075 (1.9) 2.14 (54.4) 1,990 (2,961) 380 445
750 0.968 (24.6) 1.91 (48.5) 24x14 0.075 (1.9) 2.37 (60.2) 2,595 (3,861) 470 530
1000 1.117 (28.4) 2.06 (52.3) 31x14 0.075 (1.9) 2.52 (64.0) 3,090(4,598) 530 585
Full Neutral
1/0 0.362(9.2) 1.27 (32.3) 16x14 0.050 (1.3) 1.62 (41.1) 1,055 (1,570) 160 195
2/0 0.405 (10.3) 1.31 (33.3) 20x14 0.050 (1.3) 1.66 (42.2) 1,165 (1,733) 185 220
3/0 0.456 (11.6) 1.37 (34.8) 25x14 0.050 (1.3) 1.71 (43.4) 1,295 (1,927) 210 250
4/0 0.512 (13.0) 1.42 (36.1) 32x14 0.075 (1.9) 1.82 (46.2) 1,520 (2,262) 240 285
 
CERTIFICATIONS

 

aluminum 1350 compressed lay stranded conductor cable

PACKAGING

 

Class B compressed stranded aluminum conductor MV cable
Large Wooden Reel
filled aluminum conductor TR-XLPE CN LLDPE cable
Large Wooden Reel
APPLICATION

 

unfilled aluminum conductor TR-XLPE CN LLDPE cable
Industrial Plant
water blocked aluminum primary UD cable
Mining Facility
conductor shield TR-XLPE primary UD cable
Power Plant
CASE

 

extruded semiconducting conductor shield primary cable

Battery energy storage system

super smooth conductor shield MV-90 cable

Bechatw Power Station

tree retardant cross linked polyethylene insulation cable

Bingham Canyon Mine

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

TR-XLPE insulation medium voltage cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

medium voltage cable with copper neutral wires
 
primary UD cable with LLDPE jacket and red stripes
 
high dielectric strength TR-XLPE cable
 
aluminum conductor with copper concentric neutral cable
 
treeing resistant TR-XLPE insulation cable
 
low moisture absorption primary UD cable
 
GLOBAL CERTIFICATIONS

 

low dielectric loss MV-90 cable

CUSTOMER PHOTOS
 

excellent resistance to treeing MV cable

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

90C normal operation primary UD cable
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

130C emergency overload MV-90 cable
black encapsulating LLDPE jacket cable
medium voltage cable construction aluminum TR-XLPE CN LLDPE
MV-90 cable construction details
primary underground distribution cable datasheet
250C short circuit primary UD cable
neutral wires encapsulated in LLDPE jacket cable
primary UD cable layer structure
aluminum TR-XLPE CN LLDPE cable datasheet
TRXLPE CN LLDPE cable specification
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

MV-90 Primary UD cable specification
FAQ

 

What is the core advantage of 133% IL & 420 mils insulation?
The upgraded 420 mil thick insulation and 133% insulation level provides higher overvoltage endurance, perfectly suited for ungrounded or impedance-grounded grids with slow fault-clearing times, effectively preventing insulation breakdown.
Why choose concentric neutral (CN) structure for this 35kV UD cable?
The copper concentric neutral acts as both electromagnetic shielding and reliable ground fault return path, simplifying field grounding setup, reducing installation costs and ensuring stable grid operation.
Is this cable suitable for harsh underground burial environments?
Yes. TR-XLPE insulation suppresses water tree aging, while the tough LLDPE jacket resists moisture, abrasion and soil corrosion, ensuring long service life in wet and buried conditions.
What are the standard temperature ratings for this MV-90 cable?
It supports 90°C continuous operation, 130°C emergency overload tolerance, and 250°C short-circuit resistance within 5 seconds, adapting to complex load fluctuations.

 