AL EPR/CTS/PVC Power Type MV-105 5kV 133%/8kV 100% I.L. 115 Mils Shielded

AL EPR/CTS/PVC Power Type MV-105 5kV 133%/8kV 100% I.L. 115 Mils Shielded
Details:
·Aluminum Stranded Conductor(unfilled/filled)
·Extruded Strand Shield
·EPR Insulation
·Extruded Insulation Shield
·Copper Tape Shield
·PVC Overall Jacket
·Voltage Rating:5KV-35KV
·Temperatura:105℃
·Size Range:2AWG~1000kcmil
·Standard:UL1072
·Single core
·Color:black
Send Inquiry
Download
Description
Technical Parameters
Certification

5kV aluminum MV-105 cable 133% insulation level

PRODUCT REAL SHOT

 

aluminum conductor Type MV-105 cable
aluminum Type MV-105 cable
single core aluminum medium voltage power cable

aluminum conductor medium voltage power cable

5kV 133% / 8kV 100% Insulation Level – Dual-Rated MV Cable for Versatile Industrial Power Distribution
This medium voltage cable features a dual insulation rating of 5kV at 133% and 8kV at 100% insulation level, providing exceptional versatility for industrial power applications. The aluminum conductor with EPR insulation, copper tape shield, and PVC jacket delivers reliable performance with 115 mils insulation thickness. UL1072 certified and Type MV-105 rated for 105°C continuous operation, this cable is approved for Class I, Div. 2 hazardous locations per NEC. The aluminum conductor offers significant weight reduction and cost savings, making it ideal for large-scale industrial installations. The copper tape shield ensures effective grounding and protection against electromagnetic interference, while the rugged PVC jacket provides excellent resistance to moisture, chemicals, and sunlight. This dual-rated cable offers flexibility for systems operating at different voltage levels, reducing inventory complexity and installation costs.
PRODUCT SPECIFICATIONS

 

Type MV-105 aluminum conductor power cable

Product Description

 

The Medium Voltage, EPR/Cu Tape Shield/PVC, Type MV-105 Cable consist of Aluminum Class B stranded conductors, covered with ethylene propylene rubber (EPR), copper tape shield, and black PVC jacket. These cables are used in industrial power circuits.

Applications

 
  • In conduit, duct, free air, and raceways, primary installations include cable trays, and outdoor locations
  • In direct burial if installed in a system with a ground conductor that is in close proximity, and conforms with NEC 250.4 (A)(5)
  • In wet or dry locations
  • Approved for Class I, Div. 2 industrial hazardous locations per NEC
  • Designed to operate continuously at a conductor temperature not exceeding

105°C for normal operations

140°C for emergency overload

250°C for short circuit

Features

 
  • Rated at 105°C wet or dry
  • Excellent corona resistance
  • High dielectric strength
  • Low moisture absorption
  • Low dielectric loss
  • Excellent sunlight resistance
  • For CT USE for 1/0 AWG and larger, per UL 1072
  • Meets cold bend test at -35°C
SPECIFICATIONS

Conductor Count

1 conductor

Conductor

Aluminum 1350 Class B compressed stranded (filled or unfilled)

Gauge Sizes

Available in 2 AWG through 1000 kcmil

Conductor Strand Shield

Extruded thermoset semi-conducting polymer over the conductor

Insulation

Ethylene Propylene Rubber (EPR)

Insulation Shield

Extruded thermoset semi-conducting polymer over the insulation

Shield

5 mil annealed copper tape helically applied with approximately 25% overlap

Jacket

Polyvinyl Chloride (PVC)

Jacket Marking

2 AWG - 1 AWG: 00000 FT GREATER WIRE CABLE XXAWG 1/C XXKV XXX% INSUL LEVEL XXXMILS EPR/PVC JKT TYPE MV-105 SUN RES (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)
1/0 AWG - 1000 kcmil: 00000 FT GREATER WIRE CABLE XXAWG AL (or XXXKCMIL) 1/C XXKV XXX% INSUL LEVEL XXXMILS EPR/PVC JKT TYPE MV-105 FOR CT USE (UL) SUN RES MADE IN USA MMDDYYYY (LIGHTNING BOLT)

Packaging

Non-returnable wood reels in a variety of lengths and dimensions

Performance Compliances

ASTM B230 , ASTM B231
UL 1072, UL 1685 (flame exposure test)
ANSI/NEMA WC 74/ICEA S-93-639
ANSI/ICEA S-97-682
AEIC CS8
NEC

Other Compliances

EPA 40 CFR, Part 261
OSHA

Aluminum Unfilled/Filled Cdr 5kV 100% I.L. 115mils Shielded

Conductor
Size

AWG/Kcmil

Nom. Conductor
Diameter
Insulation
Diameter

in(mm)
Jacket Thickness
in(mm)
Approx.Overall
Diameter
in(mm)
Approx. Net Weight  Ampacity
lbs/kft(kg/km) Conduit in Air Underground Duct
2 0.283(7.2) 0.57(14.5) 0.060(1.5) 0.78((19.8) 325(484) 125 130
1 0.322(8.2) 0.61(15.5) 0.060(1.5) 0.82(20.8) 360(536) 145 145
1/0 0.362(9.2) 0.65(16.5) 0.060(1.5) 0.87(22.1) 400(595) 170 165
2/0 0.405(10.3) 0.70(17.8) 0.075(1.9) 0.94(23.9) 470(699) 190 190
3/0 0.456(11.6) 0.75(19.1) 0.075(1.9) 0.99(25.1) 530(789) 220 215
4/0 0.512(13.0) 0.81(20.6) 0.075(1.9) 1.05(26.7) 600(893) 255 245
250 0.558(14.2) 0.86(21.8) 0.075(1.9) 1.10(27.9) 665(990) 280 270
350 0.661(16.8) 0.97(24.6) 0.075(1.9) 1.21(30.7) 810(1,205) 340 330
500 0.789(20.0) 1.10(27.9) 0.075(1.9) 1.34(34.0) 1,015(1,510) 425 400
750 0.968(24.6) 1.29(32.8) 0.075(1.9) 1.53(38.9) 1,350(2,009) 520 490
1000 1.117(28.4) 1.44(36.6) 0.075(1.9) 1.69(42.9) 1,660(2,470) 615 565
 
CERTIFICATIONS

 

1/C aluminum conductor MV-105 cable

PACKAGING

 

1C aluminum Type MV-105 cable
Large Wooden Reel
Al conductor MV-105 cable
Large Wooden Reel
APPLICATION

 

Aluminum Type MV cable MV-105 rated
Industrial Plant
single conductor shielded aluminum MV cable
Mining Facility
single core aluminium Type MV-105 cable
Power Plant
CASE

 

5kV single core aluminum Type MV-105 cable

Battery energy storage system

5kV aluminum conductor MV-105 cable

Bechatw Power Station

5kV single core aluminum medium voltage power cable

Bingham Canyon Mine

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

5kV aluminum Type MV cable UL 1072
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

5kV shielded aluminum MV-105 cable
 
5kV aluminum MV-105 cable manufacturer
 
5kV aluminum MV-105 cable supplier
 
5kV aluminum MV-105 cable price
 
5kV aluminum conductor MV power cable factory
 
UL listed single core aluminum Type MV-105 cable
 
GLOBAL CERTIFICATIONS

 

UL certified aluminum Type MV-105 cable

CUSTOMER PHOTOS
 

UL 1072 MV-105 aluminum conductor cable manufacturer

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

NEC Article 328 Type MV aluminum cable
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

ICEA S-93-639 aluminum medium voltage cable
ICEA NEMA aluminum MV-105 cable
AEIC CS8 aluminum MV power cable
medium voltage cable jacket types PVC CPE PE
flame retardant single core aluminum Type MV-105 cable
medium voltage cable bending radius aluminum conductor
medium voltage cable ampacity aluminum conductor
ICEA NEMA medium voltage cable
single core aluminum medium voltage cable
aluminum conductor Type MV-105 cable
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

single conductor aluminum medium voltage cable
FAQ

 

What does the dual rating 5kV 133% / 8kV 100% mean for this cable?
The cable is rated for 5kV systems at 133% insulation level and 8kV systems at 100% insulation level, providing application flexibility across different voltage requirements.
Why choose a dual-rated cable for industrial applications?
It reduces inventory requirements, simplifies specification, and offers installation flexibility for facilities with multiple voltage distribution systems.
Is this cable approved for hazardous locations?
Yes, it is approved for Class I, Div. 2 industrial hazardous locations per NEC, making it suitable for chemical plants, refineries, and similar environments.
What is the cold bend temperature rating?
This cable meets cold bend test at -35°C, ensuring reliable installation and performance in cold climate conditions.

 

Hot Tags: al epr/cts/pvc power type mv-105 5kv 133%/8kv 100% i.l. 115 mils shielded, China al epr/cts/pvc power type mv-105 5kv 133%/8kv 100% i.l. 115 mils shielded manufacturers, suppliers, factory

Send Inquiry