AL EPR/CTS/PVC Power Type MV-105 35kV 133% I.L. 420 Mils Shielded

AL EPR/CTS/PVC Power Type MV-105 35kV 133% I.L. 420 Mils Shielded
Details:
·Aluminum Stranded Conductor(unfilled/filled)
·Extruded Strand Shield
·EPR Insulation
·Extruded Insulation Shield
·Copper Tape Shield
·PVC Overall Jacket
·Voltage Rating:5KV-35KV
·Temperatura:105℃
·Size Range:2AWG~1000kcmil
·Standard:UL1072
·Single core
·Color:black
Send Inquiry
Download
Description
Technical Parameters
Certification

single core aluminum Type MV-105 cable

PRODUCT REAL SHOT

 

aluminum conductor Type MV-105 cable with metallic shield
one conductor aluminum MV-105 cable
UL listed aluminum Type MV-105 cable

AL EPR/CTS/PVC Power Type MV-105 35kV 133% I.L. 420 Mils Shielded

AL EPR/CTS/PVC Power Type MV-105 35kV 133% I.L. 420 mils Shielded
AL EPR/CTS/PVC MV-105 is a high-grade 35kV medium voltage shielded power cable featuring compact aluminum conductor, 133% insulation level and ultra-heavy 420-mil copper tape shielding. Designed for cost-effective high-voltage power transmission, it adopts 105°C heat-resistant EPR insulation, full CTS shielding structure and durable UV-stabilized PVC outer jacket. The 133% insulation level provides superior overload tolerance for prolonged single-phase ground faults, while the 420-mil thick copper tape shield precisely stabilizes electric field distribution, eliminates partial discharge and enhances system safety under high voltage. With excellent thermal stability, water-tree resistance and anti-aging performance, this aluminum MV cable features lighter weight and lower installation cost compared with copper cables. It is suitable for direct burial, conduit and cable tray installation, widely used in utility substations, industrial power feeders, municipal grid expansion and large commercial high-voltage distribution projects.
PRODUCT SPECIFICATIONS

 

35kV shielded aluminum MV-105 cable

Product Description

 

The Medium Voltage, EPR/Cu Tape Shield/PVC, Type MV-105 Cable consist of Aluminum Class B stranded conductors, covered with ethylene propylene rubber (EPR), copper tape shield, and black PVC jacket. These cables are used in industrial power circuits.

Applications

 
  • In conduit, duct, free air, and raceways, primary installations include cable trays, and outdoor locations
  • In direct burial if installed in a system with a ground conductor that is in close proximity, and conforms with NEC 250.4 (A)(5)
  • In wet or dry locations
  • Approved for Class I, Div. 2 industrial hazardous locations per NEC
  • Designed to operate continuously at a conductor temperature not exceeding

105°C for normal operations

140°C for emergency overload

250°C for short circuit

Features

 
  • Rated at 105°C wet or dry
  • Excellent corona resistance
  • High dielectric strength
  • Low moisture absorption
  • Low dielectric loss
  • Excellent sunlight resistance
  • For CT USE for 1/0 AWG and larger, per UL 1072
  • Meets cold bend test at -35°C
SPECIFICATIONS

Conductor Count

1 conductor

Conductor

Aluminum 1350 Class B compressed stranded (filled or unfilled)

Gauge Sizes

Available in 2 AWG through 1000 kcmil

Conductor Strand Shield

Extruded thermoset semi-conducting polymer over the conductor

Insulation

Ethylene Propylene Rubber (EPR)

Insulation Shield

Extruded thermoset semi-conducting polymer over the insulation

Shield

5 mil annealed copper tape helically applied with approximately 25% overlap

Jacket

Polyvinyl Chloride (PVC)

Jacket Marking

2 AWG - 1 AWG: 00000 FT GREATER WIRE XXAWG 1/C XXKV XXX% INSUL LEVEL XXXMILS EPR/PVC JKT TYPE MV-105 SUN RES (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)
1/0 AWG - 1000 kcmil: 00000 FT GREATER WIRE XXAWG AL (or XXXKCMIL) 1/C XXKV XXX% INSUL LEVEL XXXMILS EPR/PVC JKT TYPE MV-105 FOR CT USE (UL) SUN RES MADE IN USA MMDDYYYY (LIGHTNING BOLT)

Packaging

Non-returnable wood reels in a variety of lengths and dimensions

Performance Compliances

ASTM B230 , ASTM B231
UL 1072, UL 1685 (flame exposure test)
ANSI/NEMA WC 74/ICEA S-93-639
ANSI/ICEA S-97-682
AEIC CS8
NEC

Other Compliances

EPA 40 CFR, Part 261
OSHA

Aluminum Unfilled/Filled Cdr 15kV 100% I.L. 175 mils Shielded

Conductor
Size

AWG/Kcmil

Nom. Conductor
Diameter
Insulation
Diameter

in(mm)
Jacket Thickness
in(mm)
Approx.Overall
Diameter
in(mm)
Approx. Net Weight  Ampacity
lbs/kft(kg/km) Conduit in Air Underground Duct
1/0 0.362 (9.2) 1.27 (32.3) 0.075 (1.9) 1.51 (38.4) 1.035 (1.540) 170 165
2/0 0.405 (10.3) 1.31 (33.3) 0.075 (1.9) 1.55 (39.4) 1,105 (1,644) 190 190
3/0 0.456 (11.6) 1.37 (34.8) 0.075 (1.9) 1.61 (40.9) 1,185 (1,763) 220 215
4/0 0.512 (13.0) 1.42 (36.1) 0.075 (1.9) 1.66 (42.2) 1,280 (1,905) 255 245
250 0.558 (14.2) 1.48 (37.6) 0.075 (1.9) 1.72 (43.7) 1,375 (2.046) 280 270
350 0.661 (16.8) 1.58 (40.1) 0.105 (2.7) 1.89 (48.0) 1,680 (2,500) 240 330
500 0.789 (20.0) 1.71 (43.4) 0.105 (2.7) 2.02 (51.3) 1.955 (2.909) 425 400
750 0.968 (24.6) 1.91 (48.5) 0.105 (2.7) 2.22 (56.4) 2,390 (3,556) 520 490
1000 1.117 (28.4) 2.06 (52.3) 0.105 (2.7) 2.40 (61.0) 2,840 (4,226) 615 565
 
CERTIFICATIONS

 

35kV aluminum MV-105 cable manufacturer

PACKAGING

 

UL 1072 MV-105 aluminum conductor cable manufacturer
Large Wooden Reel
NEC Type MV aluminum conductor cable
Large Wooden Reel
APPLICATION

 

ICEA NEMA aluminum MV-105 cable
Industrial Plant
UL 1072 35kV aluminum MV-105 cable
Mining Facility
MV-105 aluminum cable UL 1072 compliance
Power Plant
CASE

 

35kV ICEA NEMA aluminum medium voltage cable

Battery energy storage system

35kV AEIC CS8 aluminum MV cable

Bechatw Power Station

35kV NEC Type MV aluminum conductor cable

Bingham Canyon Mine

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

35kV EPR insulated aluminum medium voltage cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

TR-XLPE insulated aluminum conductor MV-105 cable
 
TR-XLPE aluminum medium voltage cable
 
TR-XLPE insulated aluminum Type MV cable
 
aluminum conductor Type MV-105 cable with copper tape shield
 
35kV aluminum MV-105 cable with copper tape shield
 
35kV single core aluminum medium voltage cable with copper tape shield
 
GLOBAL CERTIFICATIONS

 

single core aluminum MV-105 cable with copper wire shield

CUSTOMER PHOTOS
 

shielded aluminum medium voltage cable with copper wire shield

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

35kV aluminum MV-105 cable with copper wire shield
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

35kV single core aluminum medium voltage cable with copper wire shield
single core aluminum MV-105 cable with metallic shield
aluminum conductor Type MV-105 cable with metallic shield
35kV aluminum MV-105 cable with metallic shield
35kV single core aluminum medium voltage cable with metallic shield
35kV aluminum MV-105 cable with wire shield
35kV single core aluminum medium voltage cable with wire shield
35kV aluminum MV-105 cable with tape shield
35kV single core aluminum medium voltage cable with tape shield
35kV aluminum MV-105 cable with PVC jacket
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

35kV single conductor aluminum MV cable 100% insulation level
FAQ

 

What are the main advantages of aluminum conductor over copper for this 35kV MV cable?
The compact aluminum conductor greatly reduces overall cable weight and material cost while maintaining qualified current-carrying capacity and electrical stability. It lowers transportation and laying labor costs, making it the ideal cost-performance solution for long-distance 35kV grid trunk lines and large-area power distribution projects, without sacrificing high-voltage insulation and shielding safety.
Why does this 35kV aluminum cable use 420-mil copper tape shield instead of aluminum shield?
Copper tape delivers far better conductivity, fault-current endurance and electromagnetic shielding performance than aluminum. The 420-mil heavy copper shield ensures stable electric field control under 35kV high pressure, effectively resists grid impulse voltage and avoids shield failure during long-term ground faults, guaranteeing long-term reliable operation of high-voltage aluminum conductor circuits.
What working scenarios require 133% insulation level for 35kV MV cables?
The 133% insulation level is specially designed for power systems with long-duration ground fault tolerance requirements. It offers extra insulation safety margin for unstable grid environments, frequent load fluctuations and long-distance buried lines, fully complying with ICEA and NEMA standards for industrial and utility 35kV primary feeder circuits.
What temperature ratings and environmental adaptability does this MV-105 aluminum cable have?
It supports 105°C continuous operating temperature, 130°C emergency overload temperature and 250°C instantaneous short-circuit temperature. The EPR insulation resists water tree aging and ozone corrosion, while the PVC jacket provides UV, moisture and abrasion resistance, adapting to wet underground burial, outdoor tray laying and harsh industrial environments.

 