● TC-ER (Tray Cable – Exposed Run)
TC stands for tray cable, suitable for placement in cable trays.
ER stands for "exposed run," meaning the cable can be run outside the tray for a certain distance without additional protection.
●XHHW-2: The conductor insulation type used in the cable.
XHHW is an insulation type used in high-heat and high-humidity conditions, made of cross-linked polyethylene (XLPE).
XHHW-2 designates it as suitable for use in wet/dry environments up to 90°C and offers excellent heat and moisture resistance.
● 3C:Indicates the cable contains three conductors/WC57 Method 4.
● 12AWG:Indicates the conductor size is 12 American Wire Gauge.
Application
UL1277 TC-ER XHHW-2 3C 12AWG cable is widely used in industrial automation, control systems, and power distribution. Suitable for installation in cable trays, conduit, or exposed run environments, it meets TC-ER (Exposed Run) requirements and offers flexible installation. XHHW-2 insulation offers excellent heat and moisture resistance, enabling long-term operation in environments up to 90°C, making it suitable for high-temperature or humid locations. TC-ER XHHW-2 cable is commonly used to connect motors, control cabinets, lighting circuits, and more, making it an ideal choice for powering factories, commercial buildings, and outdoor equipment.

Feature

UL1277 TC-ER XHHW-2 3C 12AWG cable is a versatile industrial control cable with excellent mechanical strength and electrical performance. It features XHHW-2 insulation, which is heat-resistant and oil-resistant, and is rated for temperatures up to 90°C (dry and wet environments). TC-ER (Tray Cable - Exposed Installation Rating) certification allows its use in cable trays and, under certain conditions, can be run without conduit, reducing installation costs. The 12AWG three-conductor design is suitable for power and control circuits and is widely used in industrial automation, building control, and lighting systems. It also offers excellent flame retardancy and complies with UL and NEC standards, making it suitable for long-term use in harsh environments.
Certification
UL1277 TC-ER XHHW-2 3C 12AWG cable holds multiple certifications, ensuring its safety and reliability in industrial and commercial applications. Compliant with the UL1277 standard, this cable is suitable for power and control circuit routing and features oil resistance and flame retardancy. Its TC-ER (Tray Cable – Exposed Run) certification allows for exposed routing without conduit under certain conditions, reducing construction costs and increasing flexibility. Furthermore, the XHHW-2 insulation complies with the UL44 standard for high-temperature and moisture resistance, with a rated temperature of up to 90°C. This cable also complies with the NEC (National Electrical Code) and RoHS (Restriction of Hazardous Substances) requirements, making it suitable for a variety of applications, including indoor and outdoor industrial control systems and machinery wiring.

Package

Production Line

Greater Wire manufacturer's advanced cable factory has an intelligent and digital manufacturing environment. Through the seamless integration of cutting-edge technology, the factory successfully eliminates errors and defects that may occur in the traditional manual assembly process. The shift to digital manufacturing not only increases efficiency but also demonstrates our commitment to providing our customers with products of the highest reliability. The smart factory framework ensures a streamlined and error-free production process, minimizing the possibility of human-related variances and increasing previously unattainable precision. Accurate and automated inspection mechanism, the factory strictly adheres to quality control. Products are thoroughly inspected from the beginning to the final stage of the manufacturing process. Digital intelligent image detection and laser technologies are used to ensure that each product meets the strict standards set by our company. This commitment to quality extends to our inspection accuracy, with automated production equipment achieving an impressive accuracy of 0.002 mm, exceeding industry benchmarks.
customer

Partner

FAQ
Q: Is the conductor of TC-ER XHHW-2 3C 12AWG cable copper or aluminum?
Q: What UL certifications does the TC-ER XHHW-2 3C 12AWG cable have?
UL1277: Suitable for power and control tray cables, approved for use in wet and dry locations, direct burial, or in trays.
UL44 Type XHHW-2: Designated with cross-linked polyethylene insulation, heat-resistant up to 90°C, and rated voltage 600V.
Q: Is the TC-ER XHHW-2 3C 12AWG cable suitable for outdoor or direct burial installations?
Hot Tags: UL1277 TC-ER Xhhw-2 3c 12awg Cable, China UL1277 TC-ER Xhhw-2 3c 12awg Cable manufacturers, suppliers, factory

|
Conductor Size
AWG/kcmil
|
Number of Conductors
|
UL TC TYPE
|
Insulation Thickness - mils
|
Jacket Thickness - mils
|
Jacket Thickness - mm
|
Approx. O.D. - Inches
|
Approx O.D. - mm
|
Cross-Sectional
Area (sq. in.)
|
Approx. Net Weight
lbs./1000'
|
Approx. Ship Weight
lbs./1000'
|
90°C Wet or Dry
NEC Ampacity (1)*
|
75°C Wet
NEC Ampacity
|
|
14(7X)
|
2 | TC | 30 | 45 | 1.14 | 0.39 | 9.8 | 0.12 | 95 | 115 | 15 | 15 |
| 3 | TC-ER | 45 | 1.14 | 0.41 | 10.3 | 0.13 | 115 | 135 | 15 | 15 | ||
| 4 | TC-ER | 45 | 1.14 | 0.44 | 11.3 | 0.15 | 140 | 160 | 15 | 15 | ||
| 5 | TC-ER | 45 | 1.14 | 0.48 | 12.2 | 0.18 | 165 | 185 | 15 | 15 | ||
| 7 | TC-ER | 45 | 1.14 | 0.52 | 13.3 | 0.21 | 200 | 220 | 15 | 14 | ||
| 9 | TC-ER | 60 | 1.52 | 0.64 | 16.2 | 0.32 | 290 | 310 | 15 | 14 | ||
| 12 | TC-ER | 60 | 1.52 | 0.71 | 18.1 | 0.40 | 370 | 390 | 12 | 10 | ||
| 19 | TC-ER | 60 | 1.52 | 0.83 | 21.0 | 0.54 | 510 | 530 | 12 | 10 | ||
| 37 | TC-ER | 80 | 2.03 | 1.14 | 29.1 | 0.03 | 985 | 1005 | 10 | 8 | ||
| 12(7X) | 2 | TC | 30 | 45 | 1.14 | 0.42 | 10.7 | 0.14 | 120 | 140 | 20 | 20 |
| 3 | TC-ER | 45 | 1.14 | 0.45 | 11.3 | 0.16 | 145 | 165 | 20 | 20 | ||
| 4 | TC-ER | 45 | 1.14 | 0.49 | 12.4 | 0.19 | 180 | 200 | 20 | 20 | ||
| 5 | TC-ER | 45 | 1.14 | 0.53 | 13.5 | 0.22 | 220 | 240 | 20 | 20 | ||
| 7 | TC-ER | 60 | 1.52 | 0.61 | 15.5 | 0.29 | 295 | 315 | 20 | 17 | ||
| 9 | TC-ER | 60 | 1.52 | 0.70 | 17.9 | 0.39 | 390 | 410 | 20 | 17 | ||
| 12 | TC-ER | 60 | 1.52 | 0.79 | 20.0 | 0.49 | 500 | 520 | 15 | 12 | ||
| 19 | TC-ER | 80 | 2.03 | 0.96 | 24.4 | 0.72 | 745 | 765 | 15 | 12 | ||
| 37 | TC-ER | 80 | 2.03 | 1.27 | 32.3 | 1.27 | 1355 | 1375 | 12 | 10 | ||
|
10(7X)
|
2 | TC | 30 | 45 | 1.14 | 0.47 | 11.9 | 0.17 | 160 | 180 | 30 | 30 |
| 3 | TC-ER | 45 | 1.14 | 0.50 | 12.7 | 0.19 | 200 | 220 | 30 | 30 | ||
| 4 | TC-ER | 60 | 1.52 | 0.58 | 14.6 | 0.26 | 270 | 290 | 30 | 28 | ||
| 5 | TC-ER | 60 | 1.52 | 0.63 | 15.9 | 0.31 | 325 | 345 | 30 | 28 | ||
| 7 | TC-ER | 60 | 1.52 | 0.68 | 17.3 | 0.36 | 405 | 425 | 28 | 24 | ||
| 9 | TC-ER | 60 | 1.52 | 0.79 | 20.1 | 0.49 | 540 | 560 | 28 | 24 | ||
| 12 | TC-ER | 80 | 2.03 | 0.93 | 23.6 | 0.68 | 745 | 765 | 20 | 17 |
| Conductor Size AWG/kcmil | UL TC TYPE | Number of Conductors | Insulation Thickness - mils | Grounding Conductor AWG* | Jacket Thickness - mils | Jacket Thickness - mm | Approx. O.D. - Inches | Approx O.D. - mm |
Cross-Sectional
Area (sq. in.)
|
Approx. Net Weight
lbs./1000'
|
Approx. Ship Weight
lbs./1000'
|
90°C Wet or Dry
NEC Ampacity (1)*
|
75°C Wet
NEC Ampacity (1)
|
|
8(7X)
|
TC-ER
|
3 | 45 | - | 60 | 1.52 | 0.65 | 16.5 | 0.33 | 323 | 346 | 55 | 50 |
| 3 | 10* | 60 | 1.52 | 0.68 | 17.3 | 0.36 | 396 | 419 | 55 | 50 | |||
| 4 | - | 60 | 1.52 | 0.71 | 18.0 | 0.40 | 414 | 443 | 45 | 40 | |||
| 4 | 10* | 60 | 1.52 | 0.71 | 18.0 | 0.40 | 443 | 472 | 45 | 40 | |||
| 6(7X) | TC-ER | 3 | 45 | - | 60 | 1.52 | 0.73 | 18.5 | 0.42 | 448 | 477 | 75 | 65 |
| 3 | 8* | 60 | 1.52 | 0.73 | 18.5 | 0.42 | 536 | 565 | 75 | 65 | |||
| 4 | - | 60 | 1.52 | 0.80 | 20.3 | 0.50 | 565 | 594 | 60 | 52 | |||
| 4 | 8* | 60 | 1.52 | 0.82 | 20.3 | 0.50 | 662 | 697 | 60 | 52 | |||
|
4(7X)
|
TC
|
3 | 45 | - | 60 | 1.52 | 0.82 | 21.8 | 0.53 | 633 | 668 | 95 | 85 |
|
TC-ER
|
3 | 8* | 60 | 1.52 | 0.82 | 21.8 | 0.53 | 732 | 767 | 95 | 85 | ||
|
TC
|
4 | - | 80 | 2.03 | 0.94 | 23.9 | 0.69 | 851 | 904 | 76 | 68 | ||
|
TC-ER
|
4 | 8* | 80 | 2.03 | 0.95 | 24.1 | 0.71 | 936 | 989 | 76 | 68 | ||
|
2(7X)
|
TC | 3 | 45 | - | 80 | 2.03 | 0.98 | 24.9 | 0.75 | 994 | 1063 | 130 | 115 |
| TC-ER | 3 | 6 | 80 | 2.03 | 0.98 | 24.9 | 0.75 | 1145 | 1214 | 130 | 115 | ||
| TC | 4 | - | 80 | 2.03 | 1.08 | 27.4 | 0.92 | 1227 | 1307 | 104 | 92 | ||
| TC-ER | 4 | 6 | 80 | 2.03 | 1.08 | 27.4 | 0.92 | 1276 | 1356 | 104 | 92 | ||
|
1(19X)
|
TC | 3 | 55 | - | 80 | 2.03 | 1.09 | 27.7 | 0.93 | 1226 | 1338 | 150 | 130 |
| TC-ER | 3 | 6 | 80 | 2.03 | 1.09 | 27.7 | 0.93 | 1398 | 1478 | 150 | 130 | ||
| TC | 4 | - | 80 | 2.03 | 1.20 | 30.5 | 1.13 | 1582 | 1694 | 120 | 104 | ||
| TC-ER | 4 | 6 | 80 | 2.03 | 1.21 | 30.7 | 1.15 | 1662 | 1787 | 120 | 104 | ||
|
1/0(19X)
|
TC | 3 | 55 | - | 80 | 2.03 | 1.17 | 29.7 | 1.08 | 1501 | 1615 | 170 | 150 |
| TC-ER | 3 | 6 | 80 | 2.03 | 1.17 | 29.7 | 1.08 | 1680 | 1805 | 170 | 150 | ||
| TC | 4 | - | 80 | 2.03 | 1.29 | 32.8 | 1.31 | 1917 | 2059 | 136 | 120 | ||
| TC-ER | 4 | 6 | 80 | 2.03 | 1.29 | 32.8 | 1.31 | 1986 | 2128 | 136 | 120 | ||
|
2/0(19X)
|
TC | 3 | 55 | - | 80 | 2.03 | 1.26 | 30.0 | 1.25 | 1812 | 1954 | 195 | 175 |
| TC-ER | 3 | 6 | 80 | 2.03 | 1.26 | 30.0 | 1.25 | 2017 | 2159 | 195 | 175 | ||
| TC | 4 | - | 80 | 2.03 | 1.39 | 35.3 | 1.52 | 2356 | 2508 | 156 | 140 | ||
| TC-ER | 4 | 6 | 80 | 2.03 | 1.39 | 35.3 | 1.52 | 2420 | 2607 | 156 | 140 | ||
|
4/0(19X)
|
TC | 3 | 55 | - | 80 | 2.03 | 1.48 | 37.6 | - | 2697 | 2884 | 260 | 230 |
| TC-ER | 3 | 4 | 80 | 2.03 | 1.49 | 37.8 | - | 2903 | 3090 | 260 | 230 | ||
| TC | 4 | - | 80 | 2.03 | 1.63 | 41.4 | - | 3466 | 3717 | 208 | 184 | ||
| TC-ER | 4 | 4 | 80 | 2.03 | 1.63 | 41.4 | - | 3564 | 4815 | 208 | 184 | ||
|
250(37X)
|
TC | 3 | 65 | - | 80 | 2.03 | 1.62 | 41.1 | - | 2952 | 3095 | 290 | 255 |
| TC-ER | 3 | 4 | 80 | 2.03 | 1.62 | 41.1 | - | 3082 | 3259 | 290 | 255 | ||
| TC | 4 | - |
110
|
2.79
|
1.86 | 47.2 | - | 3965 | 4231 | 232 | 185 | ||
| TC-ER | 4 | 4 | 110 | 2.79 | 1.86 | 47.2 | - | 4093 | 4359 | 232 | 185 | ||
|
350(37X)
|
TC | 3 | 65 | - | 110 | 2.79 | 1.89 | 48.0 | - | 4104 | 4370 | 350 | 310 |
| TC-ER | 3 | 3 | 110 | 2.79 | 1.89 | 48.0 | - | 4207 | 4536 | 350 | 310 | ||
| TC | 4 | - | 110 | 2.79 | 2.08 | 52.8 | - | 5334 | 5681 | 280 | 248 | ||
| TC-ER | 4 | 3 | 110 | 2.79 | 2.08 | 52.8 | - | 5494 | 5841 | 280 | 248 | ||
|
500(37X)
|
TC | 3 | 65 | - | 110 | 2.79 | 2.14 | 54.4 | - | 5658 | 6005 | 430 | 380 |
| TC-ER | 3 | 2 | 110 | 2.79 | 2.14 | 54.4 | - | 5861 | 6208 | 430 | 380 | ||
| TC | 4 | - | 110 | 2.79 | 2.37 | 60.2 | - | 7352 | 7911 | 344 | 304 | ||
| TC-ER | 4 | 2 | 110 | 2.79 | 2.37 | 60.2 | - | 7560 | 8119 | 344 | 304 | ||
|
750(61X)
|
TC | 3 | 80 | - | 110 | 2.79 | 2.57 | 65.3 | - | 8331 | 8958 | 535 | 475 |
| TC-ER | 3 | 1 | 110 | 2.79 | 2.57 | 65.3 | - | 8603 | 9930 | 535 | 475 | ||
| TC | 4 | - | 140 |
3.56
|
2.91 | 73.9 | - | 11080 | 11842 | 428 | 380 | ||
| TC-ER | 4 | 1 | 140 |
3.56
|
2.91 | 73.9 | - | 11343 | 12105 | 428 | 380 | ||
|
1000(61X)
|
TC | 3 | 80 | - | 140 | 3.56 | 2.94 | 74.4 | - | 11078 | 11840 | 615 | 345 |
| TC-ER | 3 | 1 | 140 | 3.56 | 2.94 | 74.4 | - | 11463 | 12396 | 615 | 345 | ||
| TC | 4 | - | 140 | 3.56 | 3.26 | 82.8 | - | 14455 | 15388 | 492 | 430 | ||
| TC-ER | 4 | 1 | 140 | 3.56 | 3.26 | 82.8 | - | 14894 | 15827 | 492 | 430 |