UL1277 TC-ER Xhhw-2 3c 12awg Cable

UL1277 TC-ER Xhhw-2 3c 12awg Cable
Details:
UL1277 certified, long service life
XHHW-2 insulation: up to 90°C, even in humid environments
The outer sheath is usually PVC, which has some oil/corrosion resistance
The outer sheath and insulation structure are strong, wear-resistant and tensile-resistant
More than 20 years of production experience
Quick online quote & free samples available
Send Inquiry
Download
Description
Technical Parameters
Certification
TC-ER Cable

 

 
UL1277 TC-ER Xhhw-2 3c 12awg Cable

● TC-ER (Tray Cable – Exposed Run)
TC
stands for tray cable, suitable for placement in cable trays.

ER stands for "exposed run," meaning the cable can be run outside the tray for a certain distance without additional protection.

XHHW-2: The conductor insulation type used in the cable.
XHHW is an insulation type used in high-heat and high-humidity conditions, made of cross-linked polyethylene (XLPE).
XHHW-2 designates it as suitable for use in wet/dry environments up to 90°C and offers excellent heat and moisture resistance.

● 3C:Indicates the cable contains three conductors/WC57 Method 4.

● 12AWG:Indicates the conductor size is 12 American Wire Gauge.

 

 

Application

 

 

UL1277 TC-ER XHHW-2 3C 12AWG cable is widely used in industrial automation, control systems, and power distribution. Suitable for installation in cable trays, conduit, or exposed run environments, it meets TC-ER (Exposed Run) requirements and offers flexible installation. XHHW-2 insulation offers excellent heat and moisture resistance, enabling long-term operation in environments up to 90°C, making it suitable for high-temperature or humid locations. TC-ER XHHW-2 cable is commonly used to connect motors, control cabinets, lighting circuits, and more, making it an ideal choice for powering factories, commercial buildings, and outdoor equipment.

flat cable application

 

Feature

 

TC-ER

 

UL1277 TC-ER XHHW-2 3C 12AWG cable is a versatile industrial control cable with excellent mechanical strength and electrical performance. It features XHHW-2 insulation, which is heat-resistant and oil-resistant, and is rated for temperatures up to 90°C (dry and wet environments). TC-ER (Tray Cable - Exposed Installation Rating) certification allows its use in cable trays and, under certain conditions, can be run without conduit, reducing installation costs. The 12AWG three-conductor design is suitable for power and control circuits and is widely used in industrial automation, building control, and lighting systems. It also offers excellent flame retardancy and complies with UL and NEC standards, making it suitable for long-term use in harsh environments.

 

Certification

 

UL1277 TC-ER XHHW-2 3C 12AWG cable holds multiple certifications, ensuring its safety and reliability in industrial and commercial applications. Compliant with the UL1277 standard, this cable is suitable for power and control circuit routing and features oil resistance and flame retardancy. Its TC-ER (Tray Cable – Exposed Run) certification allows for exposed routing without conduit under certain conditions, reducing construction costs and increasing flexibility. Furthermore, the XHHW-2 insulation complies with the UL44 standard for high-temperature and moisture resistance, with a rated temperature of up to 90°C. This cable also complies with the NEC (National Electrical Code) and RoHS (Restriction of Hazardous Substances) requirements, making it suitable for a variety of applications, including indoor and outdoor industrial control systems and machinery wiring.

TC-ER cable certification

 

Package

 

TC-ER cable package

 

Production Line

 

TC-ER cable factory

 

Greater Wire manufacturer's advanced cable factory has an intelligent and digital manufacturing environment. Through the seamless integration of cutting-edge technology, the factory successfully eliminates errors and defects that may occur in the traditional manual assembly process. The shift to digital manufacturing not only increases efficiency but also demonstrates our commitment to providing our customers with products of the highest reliability. The smart factory framework ensures a streamlined and error-free production process, minimizing the possibility of human-related variances and increasing previously unattainable precision. Accurate and automated inspection mechanism, the factory strictly adheres to quality control. Products are thoroughly inspected from the beginning to the final stage of the manufacturing process. Digital intelligent image detection and laser technologies are used to ensure that each product meets the strict standards set by our company. This commitment to quality extends to our inspection accuracy, with automated production equipment achieving an impressive accuracy of 0.002 mm, exceeding industry benchmarks.

 

customer

 

wire and cable company

 

 

Partner

 

greater wire Partner

 

FAQ

 

 

 

 

Q: Is the conductor of TC-ER XHHW-2 3C 12AWG cable copper or aluminum?

A: To ensure lower resistance, higher conductivity, and greater flexibility, most manufacturers use copper as the conductor material. While some cable models may use aluminum, aluminum is less common in smaller sizes like 12AWG. Therefore, the TC-ER XHHW-2 3C 12AWG cable typically uses copper. Please refer to the specific product specification for confirmation.

Q: What UL certifications does the TC-ER XHHW-2 3C 12AWG cable have?

A: TC-ER XHHW-2 3C 12AWG cable is typically certified by the following UL (Underwriters Laboratories) certifications:

UL1277: Suitable for power and control tray cables, approved for use in wet and dry locations, direct burial, or in trays.

UL44 Type XHHW-2: Designated with cross-linked polyethylene insulation, heat-resistant up to 90°C, and rated voltage 600V.

Q: Is the TC-ER XHHW-2 3C 12AWG cable suitable for outdoor or direct burial installations?

A: TC-ER XHHW-2 3C 12AWG cable is typically suitable for outdoor and direct burial installations. This cable features XHHW-2 insulation, which offers excellent resistance to heat, moisture, and UV rays, making it well-suited for outdoor environments. The TC-ER (Tray Cable – Exposed Run) rating indicates that it can be installed exposed without the need for additional conduit and provides some mechanical protection. Most of these cables meet the UL 1277 standard for direct burial use. However, because outer jacket material and construction may vary between manufacturers, the specific product's technical data sheet and UL filing should be consulted to ensure the cable is certified for direct burial installation. In environments with moisture, corrosive conditions, or high mechanical stress, additional protective measures are recommended to extend the lifespan.

 

 

Hot Tags: UL1277 TC-ER Xhhw-2 3c 12awg Cable, China UL1277 TC-ER Xhhw-2 3c 12awg Cable manufacturers, suppliers, factory

TC-ER cable

 

 

Conductor Size
AWG/kcmil
Number of Conductors
UL TC TYPE
Insulation Thickness - mils
Jacket Thickness - mils
Jacket Thickness - mm
Approx. O.D. - Inches
Approx O.D. - mm
Cross-Sectional
Area (sq. in.)
Approx. Net Weight
lbs./1000'
Approx. Ship Weight
lbs./1000'
90°C Wet or Dry
NEC Ampacity (1)*
75°C Wet
NEC Ampacity
14(7X)
2 TC 30 45 1.14 0.39 9.8 0.12 95 115 15 15
3 TC-ER 45 1.14 0.41 10.3 0.13 115 135 15 15
4 TC-ER 45 1.14 0.44 11.3 0.15 140 160 15 15
5 TC-ER 45 1.14 0.48 12.2 0.18 165 185 15 15
7 TC-ER 45 1.14 0.52 13.3 0.21 200 220 15 14
9 TC-ER 60 1.52 0.64 16.2 0.32 290 310 15 14
12 TC-ER 60 1.52 0.71 18.1 0.40 370 390 12 10
19 TC-ER 60 1.52 0.83 21.0 0.54 510 530 12 10
37 TC-ER 80 2.03 1.14 29.1 0.03 985 1005 10 8
12(7X) 2 TC 30 45 1.14 0.42 10.7 0.14 120 140 20 20
3 TC-ER 45 1.14 0.45 11.3 0.16 145 165 20 20
4 TC-ER 45 1.14 0.49 12.4 0.19 180 200 20 20
5 TC-ER 45 1.14 0.53 13.5 0.22 220 240 20 20
7 TC-ER 60 1.52 0.61 15.5 0.29 295 315 20 17
9 TC-ER 60 1.52 0.70 17.9 0.39 390 410 20 17
12 TC-ER 60 1.52 0.79 20.0 0.49 500 520 15 12
19 TC-ER 80 2.03 0.96 24.4 0.72 745 765 15 12
37 TC-ER 80 2.03 1.27 32.3 1.27 1355 1375 12 10
10(7X)
2 TC 30 45 1.14 0.47 11.9 0.17 160 180 30 30
3 TC-ER 45 1.14 0.50 12.7 0.19 200 220 30 30
4 TC-ER 60 1.52 0.58 14.6 0.26 270 290 30 28
5 TC-ER 60 1.52 0.63 15.9 0.31 325 345 30 28
7 TC-ER 60 1.52 0.68 17.3 0.36 405 425 28 24
9 TC-ER 60 1.52 0.79 20.1 0.49 540 560 28 24
12 TC-ER 80 2.03 0.93 23.6 0.68 745 765 20 17
Equipment Grounding Conductor: Any conductor in TC rated cables may be permanently re-identified during installation as the equipment grounding conductor in accordance with Section 250.119(B) of the NEC.
† Cross-sectional area for calculation of cable tray fill in accordance with Section 392.22 of the NEC.
 
(1) Ampacities
Ampacities are based on Table 310.16 of the National Electrical Code for these 90°C rated conductors at an ambient temperature of 30°C. The 75°C wet column is provided for additional in formation.
The ampacities shown apply to open runs of cable, installation in any approved raceway, direct burial in the earth, or as aerial cable on a messenger. Derating for more than three current carrying conductors within a raceway is in accordance with NEC Section 310.15(C)(1).
The ampacities shown also apply to cables installed in cable tray in accordance with NEC Section 392.80.
 
*Current limited to 15, 20 and 30 amps per Section 240.4(D) of the NEC for #14, #12 and #10 AWG, respectively.
 
Conductor Size AWG/kcmil UL TC TYPE Number of Conductors Insulation Thickness - mils Grounding Conductor AWG* Jacket Thickness - mils Jacket Thickness - mm Approx. O.D. - Inches Approx O.D. - mm
Cross-Sectional
Area (sq. in.)
Approx. Net Weight
lbs./1000'
Approx. Ship Weight
lbs./1000'
90°C Wet or Dry
NEC Ampacity (1)*
75°C Wet
NEC Ampacity (1)
8(7X)
TC-ER
3 45 - 60 1.52 0.65 16.5 0.33 323 346 55 50
3 10* 60 1.52 0.68 17.3 0.36 396 419 55 50
4 - 60 1.52 0.71 18.0 0.40 414 443 45 40
4 10* 60 1.52 0.71 18.0 0.40 443 472 45 40
6(7X) TC-ER 3 45 - 60 1.52 0.73 18.5 0.42 448 477 75 65
3 8* 60 1.52 0.73 18.5 0.42 536 565 75 65
4 - 60 1.52 0.80 20.3 0.50 565 594 60 52
4 8* 60 1.52 0.82 20.3 0.50 662 697 60 52
4(7X)
TC
3 45 - 60 1.52 0.82 21.8 0.53 633 668 95 85
TC-ER
3 8* 60 1.52 0.82 21.8 0.53 732 767 95 85
TC
4 - 80 2.03 0.94 23.9 0.69 851 904 76 68
TC-ER
4 8* 80 2.03 0.95 24.1 0.71 936 989 76 68
2(7X)
TC 3 45 - 80 2.03 0.98 24.9 0.75 994 1063 130 115
TC-ER 3 6 80 2.03 0.98 24.9 0.75 1145 1214 130 115
TC 4 - 80 2.03 1.08 27.4 0.92 1227 1307 104 92
TC-ER 4 6 80 2.03 1.08 27.4 0.92 1276 1356 104 92
1(19X)
TC 3 55 - 80 2.03 1.09 27.7 0.93 1226 1338 150 130
TC-ER 3 6 80 2.03 1.09 27.7 0.93 1398 1478 150 130
TC 4 - 80 2.03 1.20 30.5 1.13 1582 1694 120 104
TC-ER 4 6 80 2.03 1.21 30.7 1.15 1662 1787 120 104
1/0(19X)
TC 3 55 - 80 2.03 1.17 29.7 1.08 1501 1615 170 150
TC-ER 3 6 80 2.03 1.17 29.7 1.08 1680 1805 170 150
TC 4 - 80 2.03 1.29 32.8 1.31 1917 2059 136 120
TC-ER 4 6 80 2.03 1.29 32.8 1.31 1986 2128 136 120
2/0(19X)
TC 3 55 - 80 2.03 1.26 30.0 1.25 1812 1954 195 175
TC-ER 3 6 80 2.03 1.26 30.0 1.25 2017 2159 195 175
TC 4 - 80 2.03 1.39 35.3 1.52 2356 2508 156 140
TC-ER 4 6 80 2.03 1.39 35.3 1.52 2420 2607 156 140
4/0(19X)
TC 3 55 - 80 2.03 1.48 37.6 - 2697 2884 260 230
TC-ER 3 4 80 2.03 1.49 37.8 - 2903 3090 260 230
TC 4 - 80 2.03 1.63 41.4 - 3466 3717 208 184
TC-ER 4 4 80 2.03 1.63 41.4 - 3564 4815 208 184
250(37X)
TC 3 65 - 80 2.03 1.62 41.1 - 2952 3095 290 255
TC-ER 3 4 80 2.03 1.62 41.1 - 3082 3259 290 255
TC 4 -
110
2.79
1.86 47.2 - 3965 4231 232 185
TC-ER 4 4 110 2.79 1.86 47.2 - 4093 4359 232 185
350(37X)
TC 3 65 - 110 2.79 1.89 48.0 - 4104 4370 350 310
TC-ER 3 3 110 2.79 1.89 48.0 - 4207 4536 350 310
TC 4 - 110 2.79 2.08 52.8 - 5334 5681 280 248
TC-ER 4 3 110 2.79 2.08 52.8 - 5494 5841 280 248
500(37X)
TC 3 65 - 110 2.79 2.14 54.4 - 5658 6005 430 380
TC-ER 3 2 110 2.79 2.14 54.4 - 5861 6208 430 380
TC 4 - 110 2.79 2.37 60.2 - 7352 7911 344 304
TC-ER 4 2 110 2.79 2.37 60.2 - 7560 8119 344 304
750(61X)
TC 3 80 - 110 2.79 2.57 65.3 - 8331 8958 535 475
TC-ER 3 1 110 2.79 2.57 65.3 - 8603 9930 535 475
TC 4 - 140
3.56
2.91 73.9 - 11080 11842 428 380
TC-ER 4 1 140
3.56
2.91 73.9 - 11343 12105 428 380
1000(61X)
TC 3 80 - 140 3.56 2.94 74.4 - 11078 11840 615 345
TC-ER 3 1 140 3.56 2.94 74.4 - 11463 12396 615 345
TC 4 - 140 3.56 3.26 82.8 - 14455 15388 492 430
TC-ER 4 1 140 3.56 3.26 82.8 - 14894 15827 492 430

 

Send Inquiry