4x35MM+1x10E Low Fire Hazard 4C+E Power Cable 0.6/1kV

4x35MM+1x10E Low Fire Hazard 4C+E Power Cable 0.6/1kV
Details:
·Standard: AS/NZS 5000.1;AS/NZS 3808; AS/NZS 4507
·Voltage: 0.6/1kV
·Conductor: Plain Annealed Copper (Class 5) to AS/NZS 1125
·Insulation: X-HF-110 (Natural)
·Sheath: HFS-110-TP UV Resistant (Orange)
·Flame Propagation: IEC 60332-3 cat A IEC 60332-1
·Green Star: PVC Free
Send Inquiry
Download
Description
Technical Parameters
Certification

4×35+1×10E 110°C elastomer cable

PRODUCT REAL SHOT

 

4×35+1×10E 110C elastomer cable
4×35+1×10E 4C+E cable
4×35+1×10E 4 core and earth cable

4×35+1×10E 4 core + earth cable

3 Phase Cable with Neutral for Industrial Machinery and MCCs
The 4x35+1x10E HFS-110-TP cable is a flexible 0.6/1kV multicore construction for industrial circuits that require three phases, neutral and earth. Its Class 5 copper conductors improve handling around equipment and make it a practical 4C+E cable for industrial plants where large rigid cable can be difficult to route. It can also serve as a 4C+E cable for motor control centres when the feeder or associated controls require a neutral conductor. For machinery combining three-phase power with single-phase controls, the construction works as a three phase neutral earth cable for industrial machinery after current, fault and voltage-drop checks. GERITEL WIRE provides SAA support, dimensions, test records, OEM marking, inspection coordination and export drum packing.
PRODUCT SPECIFICATIONS

 

4×35+1×10E 3 phase neutral earth cable

Applications

 

Flexible single core X-HF-110 insulated and HFS-110-TP sheathed cable for mains, submains and subcircuits unenclosed, enclosed in conduit or in underground ducts for building and industrial plants where not subject to mechanical damage. Suitable where space is at a premium and/or where conditions of overload may occur.

SPECIFICATIONS
Approvals Suitable for fixed applications only in accordance with AS/NZS 3000+AS/NZS 5000.1
Behaviour in flame and fire: Flame propagation - AS/NZS IEC 60332-1
Temperature range

Maximum operating temperature: +110°C

Minimum operating temperature: -25°C

Minimum bending radius

Installed cables: 4D

During installation: 6D

Resistance to

Chemical exposure: OccasionaI

Mechanical impact: Light

Water exposure: Uccasional condensation

Solar radiation and weather exposure:Occasional

Cable design

Conductor: Flexible bunched annealed copper conductor to A5/NZ5 1125 (Class 5).

Insulation: X-HF-110 Colour:Natural

Sheath: HFS-110-TP Colour: Orange

Installation conditions

In free air

In conduit

In trench

In duct

Core x cross-

section

nx

mm²

Conductor Diameter

mm

Nominal insulation

thicknes

(mm)

Nominal

sheath

thickness
(mm)

Approx.

overall

diamete
(mm)

Approx.

weight

(kg/km)

phase

 

earth

 

phase

 

earth

 

4x10+1x4E 0.40 0.30 0.7 0.7 1.8 19.5 617
4x16+1x6E 0.40 0.30 0.7 0.7 1.8 21.8 868
4x25+1x6E 0.40 0.30 0.9 0.7 1.8 25.6 1245
4x35+1x10E 0.40 0.40 0.9 0.7 1.8 29.2 1694
4x50+1x16E 0.40 0.40 1.0 0.7 1.9 34.0 2376
4x70+1x25E 0.50 0.40 1.1 0.9 2.0 39.5 3316
4x95+1x25E 0.50 0.40 1.1 0.9 2.2 43.6 4208
4x120+1x35E 0.50 0.40 1.2 0.9 2.3 48.7 5343
4x150+1x50E 0.50 0.40 1.4 1.0 2.5 54.6 6720
4x185+1x70E 0.50 0.50 1.6 1.1 2.7 60.7 8283
4x240+1x95E 0.50 0.50 1.7 1.1 2.9 68.6 10802
mm²

Reactance

at 50Hz

(ohm/km)

Current Rating (A)

Electrical
Characteristics

Spaced

Touching surface

Metallic wiring

enclosure
in air

Underground

duct

one duct

Maximum DC

Resistance 20°C

Ω/km

10 0.0810 80 75 65 71 1.91
16 0.0779 106 99 84 91 1.21
25 0.0783 140 131 112 118 0.780
35 0.0761 173 162 137 143 0.554
50 0.0754 218 204 175 178 0.386
70 0.0744 273 255 217 217 0.272
95 0.0729 327 306 263 259 0.206
120 0.0723 387 360 306 298 0.161
150 0.0728 444 413 356 341 0.129
185 0.0730 505 470 402 381 0.106
240 0.0722 602 559 489 453 0.0801
CERTIFICATIONS

 

4×35+1×10E 3P+N+E cable

4×35+1×10E SAA cable

PACKAGING

 

4×35+1×10E SAA approved cable

Plastic Reel

4×35+1×10E X-HF-110 cable

Small Wooden Reel

4×35+1×10E HFS-110-TP cable

Large Wooden Reel

APPLICATION

 

4×35+1×10E LSZH cable
Industrial Equipment and Motor Power Supply
4×35+1×10E LFH cable
Switchboard and Distribution Panel Wiring
4×35+1×10E flexible power cable

Underground Cable Trench and Conduit Installation

 

CASE

 

4×35+1×10E Class 5 copper cable

Induction Melting Furnace Power System

4×35+1×10E 0.6/1kV cable

Mining Processing Plant MCC and Substation UpgradeModular Homes

4×35+1×10E mains cable

Steel Mill Walking Beam Furnace Electrical Installation

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

4×35+1×10E submains cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

4×35+1×10E feeder cable
 
4×35+1×10E switchboard cable
 
flexible stranded copper 4 core earth cable
 
plain annealed copper 4C+E cable
 
flexible copper 4 core and earth cable
 
3 phase neutral earth cable
 
GLOBAL CERTIFICATIONS

 

three phase neutral and earth cable

CUSTOMER PHOTOS
 

3 phase + neutral + earth cable

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

three phase plus neutral plus earth cable
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

3P+N+E cable
three phase cable with neutral and earth
3 phase flexible cable with neutral and earth
3 phase LSZH cable with neutral and earth
4C+E three phase cable
4C+E cable with neutral
4 core and earth cable with neutral
5 conductor flexible power cable
5 core flex alternative 4C+E
4 core & earth flexible cable Australia
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

orange 4C+E elastomer cable
FAQ

 

Is the conductor plain copper or tinned copper?
The standard construction uses plain annealed copper unless a different conductor finish is specifically engineered and approved. A plain annealed copper 4C+E cable provides the expected conductivity and flexibility for fixed power distribution. GERITEL WIRE states conductor material and class in the approved data so buyers can check what is actually supplied.
What does the 110°C rating actually mean?
The 110°C value refers to the maximum continuous operating temperature of the conductor for the specified cable system, not a 110°C ambient room temperature. GERITEL WIRE explains the 110°C flexible multicore cable rating during application review so designers can apply the correct ambient and grouping derating.
Can the cable be used in a hot plant room?
Potentially, but high ambient temperature reduces heat dissipation and may require derating. A high temperature 4C+E cable still has to be selected using the actual ambient temperature, grouping and installation method. GERITEL WIRE provides the technical inputs needed for the project engineer's thermal check.
Is this cable LSZH?
The X-HF-110/HFS-110-TP material system is designed as a low-smoke, zero-halogen / low-fire-hazard construction. GERITEL WIRE describes an offered model as a 4C+E LSZH cable only when the applicable datasheet and approval documents support that material claim.

 

Hot Tags: 4x35mm+1x10e low fire hazard 4c+e power cable 0.6/1kv, China 4x35mm+1x10e low fire hazard 4c+e power cable 0.6/1kv manufacturers, suppliers, factory, 110 elastomer cables, 110 Single Core Elastomer Cables

Send Inquiry