AL EPR/CTS/PVC Power Type MV-105 25kV 100% I.L. 260 Mils Shielded

AL EPR/CTS/PVC Power Type MV-105 25kV 100% I.L. 260 Mils Shielded
Details:
·Stranded Copper Conductor(unfilled/filled)
·Extruded Strand Shield
·Insulation:EPR
·Extruded Insulation Shield
·Copper Tape Shield
·PVC Overall Jacket
·Voltage Rating:5KV-35KV
·Temperatura:105℃
·Size Range:2AWG~1000kcmil
·Standard:UL1072
·Single core
·Color:black
Send Inquiry
Download
Description
Technical Parameters
Certification

wet location single core aluminum Type MV-105 cable

PRODUCT REAL SHOT

 

15kV water resistant aluminum MV-105 cable
sunlight resistant single core aluminum Type MV-105 cable
oil resistant aluminum medium voltage cable

medium voltage cable bending radius aluminum conductor

CTS Copper Shielded MV-105 Cable – 25kV 260 mils 100% I.L. CU EPR/PVC Construction For Power Substation
This Type MV-105 aluminum cable (copper conductor version) adopts solid copper conductor, 260 mils EPR insulation with 100% I.L. insulation level, concentric CTS copper shield and PVC outer jacket. This single core copper MV-105 cable is rated 25kV medium voltage, widely used for substation feeders, industrial plants and underground duct bank wiring.
PRODUCT SPECIFICATIONS

 

flame retardant aluminum medium voltage cable

PRODUCT DESCRIPTION

 

The Medium Voltage, EPR/Cu Tape Shield/PVC, Type MV-105 Cable consist of fully annealed bare copper Class B stranded conductors, covered with ethylene propylene rubber (EPR), copper tape shield, and black PVC jacket. These cables are used in industrial power circuits.

APPLICATIONS

 

·  In conduit, duct, free air, and raceways, primary installations include cable trays, and outdoor locations

·  In direct burial if installed in a system with a ground conductor that is in close proximity, and conforms with NEC 250.4 (A)(5)

·  In wet or dry locations

·  Approved for Class I, Div. 2 industrial hazardous locations per NEC

·  Designed to operate continuously at a conductor temperature not exceeding

   》105°C for normal operations

   》140°C for emergency overload

   》250°C for short circuit

FEATURES

 

·  Rated at 105°C wet or dry                                          · Low dielectric loss                           
·  Excellent corona resistance                                        ·  Excellent sunlight resistance                               
·  High dielectric strength                                              ·  For CT USE for 1/0 AWG and larger, per UL® 1072                      
·  Low moisture absorption                                            ·  Meets cold bend test at -35°C

SPECIFICATIONS

Conductor Count

1 conductor

Conductor

Aluminum 1350 Class B compressed strand (filled or unfilled)

Gauge Sizes

Available in 2 AWG through 1000 kcmil

Conductor Strand Shield

Extruded thermoset semi-conducting polymer over the conductor

Insulation

Ethylene Propylene Rubber (EPR)

Insulation Shield

Extruded thermoset semi-conducting polymer over the insulation

Shield

5 mil annealed copper tape helically applied with approximately 25% overlap

Jacket

Polyvinyl Chloride (PVC)

Jacket Marking

2 AWG - 1 AWG: 00000 FT GREATER WIRE CABLE XXAWG 1/C XXXV XXX% INSUL LEVEL XXXMILS EPR/PVC JKT TYPE MV-105 SUN RES (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)
1/0 AWG - 1000 kcmil: 00000 FT GREATER WIRE CABLE XXAWG (or XXXKCMIL) 1/C XXXV XXX% INSUL LEVEL XXXMILS EPR/PVC JKT TYPE MV-105 FOR CT USE (UL) SUN RES MADE IN USA MMDDYYYY (LIGHTNING BOLT)

Packaging

Non-returnable wood reels in a variety of lengths and dimensions

Performance Compliances

ASTM B230 | ASTM B231
UL 1072, UL 1685 (flame exposure test)
ANSI/NEMA WC 74/ICEA S-93-639
ANSI/ICEA S-97-682
AEIC CS8
NEC

Other Compliances

EPA 40 CFR, Part 261
OSHA

Copper Unfilled/Filled Cdr 5kV 100% I.L. 90 mils, Shielded

Conductor
Size

Nom.Conductor
Diameter

Insulation
Diameter2
Jacket Thickness2 Approx. Overall Diameter2 Approx. Net Weight2 Ampacitiy
AWG/Kcmil in (mm) in (mm) in (mm) in (mm) lbs/kft(kg/km) Conduit in Air3

Underground

Duct4

1/0 0.362(9.2) 0.94(23.9) 0.075 (1.9) 1.18(30.0) 675(1,004) 170 165
2/0 0.405(10.3) 0.99(25.1) 0.075 (1.9) 1.23 (31.2) 730(1,086) 190 190
3/0 0.456 (11.6) 1.04(26.4) 0.075 (1.9) 1.28 (32.5) 800(1,190) 220 215
4/0 0.512(13.0) 1.09(27.7) 0.075 (1.9) 1.34 (34.0) 880(1,309) 255 245
250 0.558(14.2) 1.15(29.2) 0.075 (1.9) 1.39 (35.3) 960(1,428) 280 270
350 0.661(16.8) 1.26(32.0) 0.075 (1.9) 1.50 (38.1) 1130(1,681) 340 330
500 0.789(20.0) 1.39(35.3) 0.075 (1.9) 1.63 (41.4) 1360(2,024) 425 400
750 0.968(24.6) 1.58(40.1) 0.105 (2.7) 1.89 (48.0) 1850(2,753) 520 490
1000 1.117(28.4) 1.73(43.9) 0.105 (2.7) 2.04 (51.8) 2205(3,281) 615 565
 
CERTIFICATIONS

 

flame retardant single core aluminum Type MV-105 cable

PACKAGING

 

1C aluminum Type MV-105 cable
Large Wooden Reel
Al conductor MV-105 cable
Large Wooden Reel
APPLICATION

 

direct burial single core aluminum Type MV-105 cable
Industrial Plant
15kV wet location aluminum MV-105 cable
Mining Facility
15kV direct burial aluminum MV-105 cable
Power Plant
CASE

 

water resistant single core aluminum Type MV-105 cable

Battery energy storage system

15kV tray cable application aluminum MV-105 cable

Bełchatów Power Station

tray cable application aluminum medium voltage cable

Bingham Canyon Mine

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

35kV water resistant aluminum MV-105 cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

what is Type MV-105 aluminum cable
 
aluminum conductor medium voltage cable wholesale
 
aluminum conductor medium voltage cable quote
 
single core vs multi core medium voltage cable
 
TR-XLPE vs XLPE medium voltage cable
 
Type MV cable installation requirements
 
GLOBAL CERTIFICATIONS

 

UL 1072 medium voltage cable requirements

CUSTOMER PHOTOS
 

ICEA NEMA medium voltage cable standard

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

aluminum conductor medium voltage cable exporter
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

how to select Type MV-105 cable voltage rating
what is 100% insulation level MV cable
what is 173% insulation level MV cable
aluminum conductor medium voltage cable custom
aluminum conductor medium voltage cable cost
NEC Article 328 Type MV cable guide
what is 133% insulation level MV cable
aluminum conductor MV cable advantages
XLPE vs EPR aluminum MV-105 cable
15kV vs 35kV aluminum medium voltage cable
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

aluminum conductor medium voltage cable manufacturer
FAQ

 

What is the practical difference between 100% insulation level and 133% insulation level for this 25kV CU EPR/CTS/PVC MV-105 cable with 260 mils insulation wall?
100% insulation level is the standard insulation thickness designed for normal power distribution without frequent overvoltage. The 260 mils EPR wall strictly meets the rated voltage requirement for regular underground feeder circuits. It is more cost-effective than the over-insulated 133% I.L. model for general industrial and substation projects without frequent transient surges.
Why choose CTS concentric copper shield instead of regular copper tape shield on this MV-105 medium voltage cable?
The concentric CTS shield forms a full circular conductive layer. It can effectively limit partial discharge and block electromagnetic interference, fully complying with the shielding requirement for 25kV single-conductor medium voltage power cable. It performs more stably in long-term buried installation.
Can this 25kV MV-105 cable with 100% I.L. and 260 mils EPR insulation be used for direct burial installation? Are there any NEC installation restrictions?
Yes. With EPR insulation and PVC outer sheath, it can be laid in conduit and duct bank direct burial. When directly buried, it must be installed alongside a grounding conductor as required by NEC 250.4(A)(5). It is also approved for Class I, Div.2 hazardous industrial locations.
Will the 260 mils insulation thickness of this 100% I.L. cable affect its cold bending performance in low-temperature areas?
No. This cable passes the -35°C cold bend test. The EPR insulation keeps good flexibility even with the 260 mils wall thickness, and no cracking will occur during pulling and bending in cold outdoor projects.

 

Hot Tags: al epr/cts/pvc power type mv-105 25kv 100% i.l. 260 mils shielded, China al epr/cts/pvc power type mv-105 25kv 100% i.l. 260 mils shielded manufacturers, suppliers, factory