1/0 AWG UL1277 TC-ER Tray Cable With XHHW-2 Copper Conductors

1/0 AWG UL1277 TC-ER Tray Cable With XHHW-2 Copper Conductors
Details:
·Stranded Bare Copper Conductor
·Stranded Bare Copper Ground Conductor
·XLPE Insulation
·Filler(as needed)
·Ripcord(as needed)
·PVC Overall Jacket
·Voltage Rating:600V
·Temperatura:Rated at 90℃ wet or dry
·Size Range:12AWG~750kcmil
·Standard:UL44/UL1277
·3 or 4 conductors
·Color:black
Send Inquiry
Download
Description
Technical Parameters
Certification

Control Tray Cable

PRODUCT REAL SHOT

 

Industrial Shielded Cable
XLPE Tray Cable
600V Tray Cable

Exposed Run Cable

1/0 AWG TC-ER – High-Ampacity Feeder for Critical Power Systems
Facilities with substantial power demands-large motors, welding equipment, and main distribution panels-require feeders that can handle heavy currents without excessive voltage drop. This 1/0 AWG TC-ER tray cable meets that need with XHHW-2 rated XLPE insulation that maintains full 90°C ampacity in wet and dry conditions. The stranded pure copper conductors ensure low resistance and efficient power delivery over longer runs. Certified to both UL1277 and UL44, the cable carries a 600V rating and is approved for exposed run tray installations. Industrial plants, power substations, and mining operations rely on this gauge for dependable heavy-duty feeders.
PRODUCT SPECIFICATIONS

 

Oil Resistant Tray Cable

Product Description

 

The XLPE/PVC, 600V Power, Type TC-ER Direct Burial Cable consist of fully annealed bare copper Class B stranded conductors, covered with oil and gas resistant Cross-linked Polyethylene (XLPE) insulation, unshielded and black PVC jacket. These cables are used in industrial power.

Applications

 
  • In conduit, duct, free air, raceways and direct burial, primary installations include cable trays, and outdoor locations
  • In wet or dry locations
  • Approved for Class I, Div. 2 industrial hazardous locations per NEC
  • Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors

Features

 
  • Rated at 90°C wet or dry
  • Ripcord (as needed)
  • Excellent sunlight resistance
  • Meets cold bend test at -25°C
SPECIFICATIONS

Conductor Count

Available in 3 or 4 conductors

Conductor

Fully annealed bare copper Class B compressed strand per ASTM B8

Gauge Sizes

Available in 12 AWG through 750 kcmil

Insulation

Cross-linked Polyethylene (XLPE)

  • All gauges are type XHHW-2
Color Coding Per ICEA S-58-679 Method 4 or Method 1, Table E-1 (K-1) or E-2 (K-2); additional color coding options available
Fillers Non-hygroscopic fillers, as necessary to obtain a circular cross section
Ground Conductor Uninsulated bare copper ground
Optional: Insulated ground
Jacket Polyvinyl Chloride (PVC)

Jacket Marking

00000 FT GREATER WIRE XXXAWG XX/C XHHW-2 PVC JKT 600V 90C WET OR DRY TYPE TC-ER (UL) SUN RES DIR BURIAL MADE IN USA MMDDYYYY

Packaging

Non-returnable wood reels in a variety of lengths and dimensions

Performance Compliances

ASTM B3 ,ASTM B8
UL 44
UL 1277
UL1685 (flame compliance)
ANSI/NEMA WC 70/ICEA S-95-658
NEC

Other Compliances

EPA 40 CFR, Part 261
OSHA
RoHS-compliant/RoHS 2-compliant
REACH-compliant

TC-ER Tray Cable with XHHW Copper Conductors Data Sheet

Conductor Count Conductor Size AWG/kcmil Ground Size AWG Insulation Thickness 
in (mm)
Jacket Thickness 
in (mm)
Approx. Overall Diameter 
in (mm)
Approx. Net Weight 
lbs/kft (kg/km)

3

12 12 0.030(0.76) 0.045(1.14) 0.43(11.0) 140(205)
4 12 12 0.030(0.76) 0.045(1.14) 0.47(12.0) 170(249)
3 10 10 0.030(0.76) 0.045(1.14) 0.49(12.4) 195(289)
4 10 10 0.030(0.76) 0.045(1.14) 0.53(13.5) 240(354)
3 8 10 0.045(1.14) 0.060(1.52) 0.65(16.5) 310(456)
4 8 10 0.045(1.14) 0.060(1.52) 0.71(18.1) 380(562)
3 6 8 0.045(1.14) 0.060(1.52) 0.73(18.5) 435(647)
4 6 8 0.045(1.14) 0.060(1.52) 0.80(20.3) 540(803)
3 4 8 0.045(1.14) 0.060(1.52) 0.83(21.1) 605(900)
4 4 8 0.045(1.14) 0.080(2.03) 0.95(24.3) 800(1,191)
3 2 6 0.045(1.14) 0.080(2.03) 1.00(25.3) 935(1,391)
4 2 6 0.045(1.14) 0.080(2.03) 1.10(27.8) 1,180(1,753)
3 1 6 0.055(1.40) 0.080(2.03) 1.12(28.6) 1,150(1,711)
4 1 6 0.055(1.40) 0.080(2.03) 1.24(31.4) 1,460(2,169)
3 1/0 6 0.055(1.40) 0.080(2.03) 1.21(30.7) 1,385(2,056)
4 1/0 6 0.055(1.40) 0.080(2.03) 1.33(33.9) 1,765(2,622)
3 2/0 6 0.055(1.40) 0.080(2.03) 1.30(33.1) 1,670(2,484)
4 2/0 6 0.055(1.40) 0.080(2.03) 1.44(36.5) 2,140(3,184)
3 3/0 4 0.055(1.40) 0.080(2.03) 1.41(35.9) 2,080(3,089)
4 3/0 4 0.055(1.40) 0.080(2.03) 1.56(39.7) 2,665(3,959)
3 4/0 4 0.055(1.40) 0.080(2.03) 1.53(39.0) 2,530(3,758)
4 4/0 4 0.055(1.40) 0.080(2.03) 1.70(43.1) 3,255(4,838)
3 250 4 0.065(1.65) 0.080(2.03) 1.68(42.7) 2,965(4,407)
4 250 4 0.065(1.65) 0.110(2.79) 1.92(48.8) 3,935(5,852)
3 350 3 0.065(1.65) 0.110(2.79) 1.96(49.9) 4,125(6,135)
4 350 3 0.065(1.65) 0.110(2.79) 2.17(55.2) 5,320(7,916)
3 500 2 0.065(1.65) 0.110(2.79) 2.24(56.9) 5,685(8,459)
4 500 2 0.065(1.65) 0.110(2.79) 2.48(63.0) 7,365(10,958)
3 750 1 0.080(2.03) 0.110(2.79) 2.69(68.4) 8,340(12,408)
4 750 1 0.080(2.03) 0.140(3.56) 3.05(77.5) 11,035(16,418)
 
CERTIFICATIONS

 

Multi-Conductor TC-ER Cable

PACKAGING

 

PLC Control Cable
Large Wooden Reel
Machine Wiring Cable
Large Wooden Reel
APPLICATION

 

Hazardous Area Cable
Industrial Plant
UL1277 Cable Standard
Mining Facility
TC-ER vs MC Cable
Power Plant
CASE

 

UL1277 TC-ER Tray Cable

Battery energy storage system

Industrial Tray Cable

Bechatw Power Station

600V Tray Cable

Bingham Canyon Mine

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

EMI Shielded Tray Cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

Copper Stranded Tray Cable
 
XLPE Insulated Tray Cable
 
NEC TC-ER Cable
 
UL Industrial Cable Standard
 
4 Conductor TC-ER
 
3 Conductor Tray Cable
 
GLOBAL CERTIFICATIONS

 

Wet Location Cable

CUSTOMER PHOTOS
 

VW-1 Rated

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

FT4 Rated Cable
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

Direct Burial Cable
Flexible Tray Cable
Mining Power Cable
EMI Shielded Tray
NEC TC-ER Cable
Nylon Jacket Cable
Industrial Automation Cable
ESS Battery Cable
Heavy Duty Mining Cable
Industrial Control Wiring
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

PLC Control Cable
FAQ

 

What does XHHW-2 mean for performance?
XHHW-2 indicates 90°C rating in both dry and wet locations, providing full ampacity regardless of moisture exposure.
What is the typical ampacity of 1/0 AWG TC-ER?
Ampacity depends on installation conditions. Consult the manufacturer's ampacity tables for specific ratings based on temperature and installation method.
What certifications ensure this cable meets safety standards?
UL1277 for tray cable and UL44 for thermoset-insulated wire, with 600V rating.
Is this cable suitable for motor control center feeders?
Yes, 1/0 AWG TC-ER is commonly used for feeders to motor control centers and large distribution panels.

 