2 AWG TC-ER Tray Cable With XHHW Copper Conductors

2 AWG TC-ER Tray Cable With XHHW Copper Conductors
Details:
·Stranded Bare Copper Conductor
·Stranded Bare Copper Ground Conductor
·XLPE Insulation
·Filler(as needed)
·Ripcord(as needed)
·PVC Overall Jacket
·Voltage Rating:600V
·Temperatura:Rated at 90℃ wet or dry
·Size Range:12AWG~750kcmil
·Standard:UL44/UL1277
·3 or 4 conductors
·Color:black
Send Inquiry
Download
Description
Technical Parameters
Certification

TC Cable

PRODUCT REAL SHOT

 

Shielded Tray Cable
XHHW Tray Cable
XHHW Cable

Power Tray Cable

2 AWG TC-ER Tray Cable With XHHW Copper Conductors – for Industrial Control and Hazardous Zone Power Circuits
For mid-sized industrial equipment and control panels, 2 AWG TC-ER tray cable balances ampacity and easy installation. As a reliable TC-ER Cable Manufacturer, we build it to meet strict TC-ER Cable Standards UL1277. Its flexible XHHW copper conductors and heat/oil resistant XLPE insulation suit tough factory environments. UV-resistant PVC jacket allows exposed tray runs without conduit. It is widely used for Industrial Control Wiring and certified as safe Hazardous Area Cable Wiring for Class I Div.2 sites, ideal when smaller cables lack capacity and larger sizes waste cost.
PRODUCT SPECIFICATIONS

 

Mining Equipment Cable

Product Description

 

The XLPE/PVC, 600V Power, Type TC-ER Direct Burial Cable consist of fully annealed bare copper Class B stranded conductors, covered with oil and gas resistant Cross-linked Polyethylene (XLPE) insulation, unshielded and black PVC jacket. These cables are used in industrial power.

Applications

 
  • In conduit, duct, free air, raceways and direct burial, primary installations include cable trays, and outdoor locations
  • In wet or dry locations
  • Approved for Class I, Div. 2 industrial hazardous locations per NEC
  • Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors

Features

 
  • Rated at 90°C wet or dry
  • Ripcord (as needed)
  • Excellent sunlight resistance
  • Meets cold bend test at -25°C
SPECIFICATIONS

Conductor Count

Available in 3 or 4 conductors

Conductor

Fully annealed bare copper Class B compressed strand per ASTM B8

Gauge Sizes

Available in 12 AWG through 750 kcmil

Insulation

Cross-linked Polyethylene (XLPE)

  • All gauges are type XHHW-2
Color Coding Per ICEA S-58-679 Method 4 or Method 1, Table E-1 (K-1) or E-2 (K-2); additional color coding options available
Fillers Non-hygroscopic fillers, as necessary to obtain a circular cross section
Ground Conductor Uninsulated bare copper ground
Optional: Insulated ground
Jacket Polyvinyl Chloride (PVC)

Jacket Marking

00000 FT GREATER Wire XXXAWG XX/C XHHW-2 PVC JKT 600V 90C WET OR DRY TYPE TC-ER (UL) SUN RES DIR BURIAL MADE IN USA MMDDYYYY

Packaging

Non-returnable wood reels in a variety of lengths and dimensions

Performance Compliances

ASTM B3 ,ASTM B8
UL 44
UL1277
UL1685 (flame compliance)
ANSI/NEMA WC 70/ICEA S-95-658
NEC

Other Compliances

EPA 40 CFR, Part 261
OSHA
RoHS-compliant/RoHS 2-compliant
REACH-compliant

TC-ER Tray Cable with XHHW Copper Conductors Data Sheet

Conductor Count Conductor Size AWG/kcmil Ground Size AWG Insulation Thickness 
in (mm)
Jacket Thickness 
in (mm)
Approx. Overall Diameter 
in (mm)
Approx. Net Weight 
lbs/kft (kg/km)

3

12 12 0.030(0.76) 0.045(1.14) 0.43(11.0) 140(205)
4 12 12 0.030(0.76) 0.045(1.14) 0.47(12.0) 170(249)
3 10 10 0.030(0.76) 0.045(1.14) 0.49(12.4) 195(289)
4 10 10 0.030(0.76) 0.045(1.14) 0.53(13.5) 240(354)
3 8 10 0.045(1.14) 0.060(1.52) 0.65(16.5) 310(456)
4 8 10 0.045(1.14) 0.060(1.52) 0.71(18.1) 380(562)
3 6 8 0.045(1.14) 0.060(1.52) 0.73(18.5) 435(647)
4 6 8 0.045(1.14) 0.060(1.52) 0.80(20.3) 540(803)
3 4 8 0.045(1.14) 0.060(1.52) 0.83(21.1) 605(900)
4 4 8 0.045(1.14) 0.080(2.03) 0.95(24.3) 800(1,191)
3 2 6 0.045(1.14) 0.080(2.03) 1.00(25.3) 935(1,391)
4 2 6 0.045(1.14) 0.080(2.03) 1.10(27.8) 1,180(1,753)
3 1 6 0.055(1.40) 0.080(2.03) 1.12(28.6) 1,150(1,711)
4 1 6 0.055(1.40) 0.080(2.03) 1.24(31.4) 1,460(2,169)
3 1/0 6 0.055(1.40) 0.080(2.03) 1.21(30.7) 1,385(2,056)
4 1/0 6 0.055(1.40) 0.080(2.03) 1.33(33.9) 1,765(2,622)
3 2/0 6 0.055(1.40) 0.080(2.03) 1.30(33.1) 1,670(2,484)
4 2/0 6 0.055(1.40) 0.080(2.03) 1.44(36.5) 2,140(3,184)
3 3/0 4 0.055(1.40) 0.080(2.03) 1.41(35.9) 2,080(3,089)
4 3/0 4 0.055(1.40) 0.080(2.03) 1.56(39.7) 2,665(3,959)
3 4/0 4 0.055(1.40) 0.080(2.03) 1.53(39.0) 2,530(3,758)
4 4/0 4 0.055(1.40) 0.080(2.03) 1.70(43.1) 3,255(4,838)
3 250 4 0.065(1.65) 0.080(2.03) 1.68(42.7) 2,965(4,407)
4 250 4 0.065(1.65) 0.110(2.79) 1.92(48.8) 3,935(5,852)
3 350 3 0.065(1.65) 0.110(2.79) 1.96(49.9) 4,125(6,135)
4 350 3 0.065(1.65) 0.110(2.79) 2.17(55.2) 5,320(7,916)
3 500 2 0.065(1.65) 0.110(2.79) 2.24(56.9) 5,685(8,459)
4 500 2 0.065(1.65) 0.110(2.79) 2.48(63.0) 7,365(10,958)
3 750 1 0.080(2.03) 0.110(2.79) 2.69(68.4) 8,340(12,408)
4 750 1 0.080(2.03) 0.140(3.56) 3.05(77.5) 11,035(16,418)
 
CERTIFICATIONS

 

Oil and Gas Electrical Cable

PACKAGING

 

Exposed Run Cable
Large Wooden Reel
Battery Energy Storage Cable
Large Wooden Reel
APPLICATION

 

Wet Location Cable
Industrial Plant
12 AWG Tray Cable
Mining Facility
600V Rated Cable
Power Plant
CASE

 

2 AWG Tray Cable

Battery energy storage system

250 kcmil Tray Cable

Bechatw Power Station

2 Conductor Tray Cable

Bingham Canyon Mine

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

8 AWG Tray Cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

Sunlight Resistant Cable
 
Dry Location Cable
 
90°C Rated Cable
 
Oil Resistant Cable
 
Flame Retardant Cable
 
Direct Burial Cable
 
GLOBAL CERTIFICATIONS

 

Solar Power Distribution Cable

CUSTOMER PHOTOS
 

Renewable Energy Electrical Cable

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

FT4 Rated Cable
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

VW-1 Rated Cable
BESS Wiring Cable
Cable Tray Rated Cable
Electrical Infrastructure Cable
Medium Power Cable Systems
Refinery Cable Systems
ESS Battery Cable
Solar Farm Electrical Cable
Heavy Duty Mining Cable
Petrochemical Plant Cable
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

Underground Mining Electrical Cable
FAQ

 

Why cooperate with a professional TC-ER Cable Manufacturer?
Qualified manufacturers strictly follow TC-ER Cable Standards UL1277, provide full certification and stable bulk pricing for industrial projects.
Where is this cable commonly used?
It serves all types of Industrial Control Wiring, and is approved as certified Hazardous Area Cable Wiring for chemical and mining plants.
What standard does this cable follow?
It complies with core TC-ER Cable Standards UL1277, plus UL44 for XHHW insulation and NEC hazardous location codes.
Can it run exposed on cable trays?
Yes. UL1277 listing permits exposed installation, greatly cutting construction time for Industrial Control Wiring layouts.

 

Hot Tags: 2 awg tc-er tray cable with xhhw copper conductors, China 2 awg tc-er tray cable with xhhw copper conductors manufacturers, suppliers, factory

Send Inquiry