PRODUCT REAL SHOT




2 AWG TC-ER Tray Cable With XHHW Copper Conductors – for Industrial Control and Hazardous Zone Power Circuits
PRODUCT SPECIFICATIONS

Product Description
The XLPE/PVC, 600V Power, Type TC-ER Direct Burial Cable consist of fully annealed bare copper Class B stranded conductors, covered with oil and gas resistant Cross-linked Polyethylene (XLPE) insulation, unshielded and black PVC jacket. These cables are used in industrial power.
Applications
- In conduit, duct, free air, raceways and direct burial, primary installations include cable trays, and outdoor locations
- In wet or dry locations
- Approved for Class I, Div. 2 industrial hazardous locations per NEC
- Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors
Features
- Rated at 90°C wet or dry
- Ripcord (as needed)
- Excellent sunlight resistance
- Meets cold bend test at -25°C
| SPECIFICATIONS | |
|
Conductor Count |
Available in 3 or 4 conductors |
|
Conductor |
Fully annealed bare copper Class B compressed strand per ASTM B8 |
|
Gauge Sizes |
Available in 12 AWG through 750 kcmil |
|
Insulation |
Cross-linked Polyethylene (XLPE)
|
| Color Coding | Per ICEA S-58-679 Method 4 or Method 1, Table E-1 (K-1) or E-2 (K-2); additional color coding options available |
| Fillers | Non-hygroscopic fillers, as necessary to obtain a circular cross section |
| Ground Conductor | Uninsulated bare copper ground Optional: Insulated ground |
| Jacket | Polyvinyl Chloride (PVC) |
|
Jacket Marking |
00000 FT GREATER Wire XXXAWG XX/C XHHW-2 PVC JKT 600V 90C WET OR DRY TYPE TC-ER (UL) SUN RES DIR BURIAL MADE IN USA MMDDYYYY |
|
Packaging |
Non-returnable wood reels in a variety of lengths and dimensions |
|
Performance Compliances |
ASTM B3 ,ASTM B8 UL 44 UL1277 UL1685 (flame compliance) ANSI/NEMA WC 70/ICEA S-95-658 NEC |
|
Other Compliances |
EPA 40 CFR, Part 261 OSHA RoHS-compliant/RoHS 2-compliant REACH-compliant |
TC-ER Tray Cable with XHHW Copper Conductors Data Sheet
| Conductor Count | Conductor Size AWG/kcmil | Ground Size AWG | Insulation Thickness in (mm) |
Jacket Thickness in (mm) |
Approx. Overall Diameter in (mm) |
Approx. Net Weight lbs/kft (kg/km) |
|
3 |
12 | 12 | 0.030(0.76) | 0.045(1.14) | 0.43(11.0) | 140(205) |
| 4 | 12 | 12 | 0.030(0.76) | 0.045(1.14) | 0.47(12.0) | 170(249) |
| 3 | 10 | 10 | 0.030(0.76) | 0.045(1.14) | 0.49(12.4) | 195(289) |
| 4 | 10 | 10 | 0.030(0.76) | 0.045(1.14) | 0.53(13.5) | 240(354) |
| 3 | 8 | 10 | 0.045(1.14) | 0.060(1.52) | 0.65(16.5) | 310(456) |
| 4 | 8 | 10 | 0.045(1.14) | 0.060(1.52) | 0.71(18.1) | 380(562) |
| 3 | 6 | 8 | 0.045(1.14) | 0.060(1.52) | 0.73(18.5) | 435(647) |
| 4 | 6 | 8 | 0.045(1.14) | 0.060(1.52) | 0.80(20.3) | 540(803) |
| 3 | 4 | 8 | 0.045(1.14) | 0.060(1.52) | 0.83(21.1) | 605(900) |
| 4 | 4 | 8 | 0.045(1.14) | 0.080(2.03) | 0.95(24.3) | 800(1,191) |
| 3 | 2 | 6 | 0.045(1.14) | 0.080(2.03) | 1.00(25.3) | 935(1,391) |
| 4 | 2 | 6 | 0.045(1.14) | 0.080(2.03) | 1.10(27.8) | 1,180(1,753) |
| 3 | 1 | 6 | 0.055(1.40) | 0.080(2.03) | 1.12(28.6) | 1,150(1,711) |
| 4 | 1 | 6 | 0.055(1.40) | 0.080(2.03) | 1.24(31.4) | 1,460(2,169) |
| 3 | 1/0 | 6 | 0.055(1.40) | 0.080(2.03) | 1.21(30.7) | 1,385(2,056) |
| 4 | 1/0 | 6 | 0.055(1.40) | 0.080(2.03) | 1.33(33.9) | 1,765(2,622) |
| 3 | 2/0 | 6 | 0.055(1.40) | 0.080(2.03) | 1.30(33.1) | 1,670(2,484) |
| 4 | 2/0 | 6 | 0.055(1.40) | 0.080(2.03) | 1.44(36.5) | 2,140(3,184) |
| 3 | 3/0 | 4 | 0.055(1.40) | 0.080(2.03) | 1.41(35.9) | 2,080(3,089) |
| 4 | 3/0 | 4 | 0.055(1.40) | 0.080(2.03) | 1.56(39.7) | 2,665(3,959) |
| 3 | 4/0 | 4 | 0.055(1.40) | 0.080(2.03) | 1.53(39.0) | 2,530(3,758) |
| 4 | 4/0 | 4 | 0.055(1.40) | 0.080(2.03) | 1.70(43.1) | 3,255(4,838) |
| 3 | 250 | 4 | 0.065(1.65) | 0.080(2.03) | 1.68(42.7) | 2,965(4,407) |
| 4 | 250 | 4 | 0.065(1.65) | 0.110(2.79) | 1.92(48.8) | 3,935(5,852) |
| 3 | 350 | 3 | 0.065(1.65) | 0.110(2.79) | 1.96(49.9) | 4,125(6,135) |
| 4 | 350 | 3 | 0.065(1.65) | 0.110(2.79) | 2.17(55.2) | 5,320(7,916) |
| 3 | 500 | 2 | 0.065(1.65) | 0.110(2.79) | 2.24(56.9) | 5,685(8,459) |
| 4 | 500 | 2 | 0.065(1.65) | 0.110(2.79) | 2.48(63.0) | 7,365(10,958) |
| 3 | 750 | 1 | 0.080(2.03) | 0.110(2.79) | 2.69(68.4) | 8,340(12,408) |
| 4 | 750 | 1 | 0.080(2.03) | 0.140(3.56) | 3.05(77.5) | 11,035(16,418) |
CERTIFICATIONS

PACKAGING


APPLICATION



CASE

Battery energy storage system

Bechatw Power Station

Bingham Canyon Mine
WHY CHOOSE US
in one-stop service
Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.
With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.
We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.
Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

PLANT EQUIPMENT






GLOBAL CERTIFICATIONS

CUSTOMER PHOTOS

INTERNATIONL TRANSPORTATION
01
Sea Freight
We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.
02
Air Freight
For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.
03
International Express
Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

COOPERATIVE PARTNER
We are looking for a cooperative partner to expand our business.










Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.
Our address
Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China
Phone Number
+86 136 6257 9592
+86 135 1078 4550
manager01@greaterwire.com

FAQ
Hot Tags: 2 awg tc-er tray cable with xhhw copper conductors, China 2 awg tc-er tray cable with xhhw copper conductors manufacturers, suppliers, factory