The SAA Australia 2hr fire rated cable is made of high-quality fire-resistant materials, mainly including insulation and sheath layers. The insulation layer is made of flame-retardant cross-linked polyolefin insulation material, which has good insulation and heat resistance properties. The sheath layer is made of thermoplastic polyolefin material, which can effectively prevent the spread of flames.
Fire rated wire can maintain circuit integrity for at least two hours under fire conditions. The design and manufacturing standards of this fire proof wire comply with relevant safety regulations in Australia to ensure that in the event of a fire, the fire proof cable can maintain the continuity and stability of the circuit, thereby ensuring the normal operation of critical facilities such as emergency lighting, fire observation, signal sensing sensor systems, exhaust fan systems, and communication systems. The fire resistance performance of the Australian standard 2 hour fire rated cable is ensured through specific tests and certifications, including fire resistance time testing, mechanical protection testing, and spray testing, to ensure that the 2 hour fire rated cable can maintain stable electrical performance under high temperature and flame conditions
Australian AS/NZS3013 WS52W Grade and Requirements
Australian AS/NZS3013 provides a detailed classification of the specific fire resistance levels for fire resistant cables. For example, AS/NZS3013 code: WS52W. WS wiring system, the second number represents the fire resistance time: 5 represents a 120 minute fire resistance test. The third number represents the mechanical protection range of the cable system when subjected to impact and shear. The fourth letter W means water, which means that a spray test should be conducted on the cable to verify the integrity of the circuit. The water spray test is conducted after the combustion test. The spraying time is 180 seconds, and the combustion conditions are 1050 ℃ for 120 minutes.
The usage scenarios of the Australian standard 2 hour fire rated cable usually include important facilities such as high-rise buildings, underground railways, large power stations, as well as industrial and mining enterprises that require high safety standards. These places have extremely high requirements for the safety and reliability of fire rated wires, so using Australian standard 2hr fire rated cables can effectively improve the safety factor of these places and ensure the safety of personnel and property